SMC Corporation of America
Elite Part Number Search
Search Results "MHKL2-20C"

Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).

Flow classification 11 The relation of the average free path of gas molecules and the pipe diameter D expressed as /D is the Knudsen number, and the relation of the pressure p(Torr) converted to air at 20C is expressed as pD.

65 or less 20 Red White 21 Brown White Withstand pressure V, 1 min, AC 1000 22 Pink Red 23 Gray Red Insulation resistance Mkm, 20C 5 or more 24 Black White 25 White None The minimum bending radius for D-sub connector cables is 20 mm. 26 Light blue None 19 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Wiring & Light / Surge Voltage Suppressor How to calculate Flow (At an air temperature 20C) AC AND 100 VDC AC AND 100 VDC WITH LIGHT WITH LIGHT TERMINAL no.1 (+) TERMINAL no.1 (+) Subsonic flow: P1+0.1013<1.89(P2+0.1013) SINGLE SINGLE Q=226S P(P2+0.1013) Sonic flow: P1+0.1013>1.89(P2+0.1013) ZNR ZNR Q=113S(P1+0.1013) Q: Flow rate under standard conditions [l/min(ANR)] S: Effective area (mm2

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

ASD330F CM2 VZ500 TU0604 1 m AN11001 25 Cylinder size 32 Values at 0.5 MPa and 20C. Cylinder extension speed: 100 mm/s Meter-out needle fully open 100 mm/s Return speed Solenoid valve (Reference) Recommended circuit for high return speed When low extension speed and high return speed are desired, the following circuit using 3-port is recommended.

(Coil temperature: 20C, at rated voltage, without surge suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

Note 3) Temperature conditions: at 20C (5C), in other cases, 6C F.S.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

Note) The values are for an ambient temperature of 20C and at the of rated voltage. How to order solenoid coil assembly Name plate part no. Clip 1 1 G N VX02 AZ-T-VX Valve model Enter by referring to How to Order (Single Unit). Name plate Series Valve/Material 1 2 3 VX21 VX22 VX23 Symbol Valve N.C. N.O. Solenoid coil Nil 2 Clip part no. (For N.C.)

N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C (N) 31 Single acting type, normally closed 6 115 16 MHZ2-16C (N) 56 10 240 20 MHZ2-20C

Item Property Conductor resistance /km, 20C 65 or less Voltage limit V, 1 minute, AC 1000 Circular connector cable assembly Insulation resistance M/km, 20C Note) When using the negative COM specification, use valves for negative COM. 5 or more Assembly part no.

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition.

Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.

Note AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 1.5 m 3 m 5 m Conductor resistance /km, 20C 65 or less Cable 25 cores x 24AWG Withstand pressure V, 1 min, AC 1000 For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius for D-sub connector cables is 20 mm.

Item Conductor resistance /km, 20C Characteristics Cable length (L) Assmbly part no. Note Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg.

2000 / 2500 Circuit Breaker(Note 3) A 10 15 Condenser Air cooling Refrigerant R407C (HFC) Refrigerant Charge g 42010 47010 73010 83010 55010 72010 Air IN/OUT Connection R1 R11/2 R2 Drain Connection mm 10 Coating Color Panel: Urbanwhite 1 Base: Urbangray 2 Weight kg 54 62 100 116 Applicable Compressor(Standard) kW 22 37 55 75 Note1: The data for m3/h (ANR) is referring to the conditions of 20C

Air flow rate m3/min(ANR) Note1) (50/60Hz) 0.32/0.375 Outlet air temp. 10 Note1The data for ANR is referring to the conditions of 20C, 1atm. pressure & relative humidity of 65%.