FEP Tubing (Fluoropolymer) Heat resistance:200C It changes according to the operating pressure.
Heat resistance:200C It changes according to the operating pressure.
(mm) Color Symbol N R BU B Translucent Red (Translucent) Blue (Translucent) Black (Opaque) Inch nominal size Inch nominal size 5/32" 5/16" Operating Temperature: Max. 200C It varies depending on the operating pressure. Refer to the graph for the maximum operating pressure.
Fluoropolymer Fittings LQ series 0.5 0.19 0.09 0.04 2.0 400 290 0.7 0.26 0.12 0.05 2.8 220 160 1.0 0.43 0.20 0.08 4.6 95 60 1.0 0.62 0.28 0.12 6.7 60 30 1.0 0.73 0.34 0.14 7.9 35 20 20C 100C 200C 260C 1.0 0.62 0.28 0.12 6.7 25 20 1.0 0.92 0.42 0.17 9.9 10 6 1.0 0.59 0.27 0.11 6.4 20 12 0.6 0.24 0.11 0.05 2.6 220 160 0.7 0.27 0.12 0.05 2.9 130 110 0.9 0.33 0.15 0.06 3.6 100 65 1.0 0.43 0.20
Applicable to TD TID Maximum operating temperature 200C chemical liquids such as acid, alkali and deionized water. As the tube runs through the fitting itself, a setting is available for any optional position. TH TIH Taper thread Thread type: R, NPT Body Material: New PFA Collet The tube is held securely in place by the tightening nut and collet.
" 9.53 TID13 1/2" 12.7 inch mm 1/8" 3.18 Tubing O.D. 0.124" (1/8") 0.156" (5/32") 0.25" (1/4") 0.374" (3/8") 0.086" inch Tubing I.D. mm 8 m 16 m 2.18 3.15 3.95 6.33 9.5 Flexibility: Improved by approx. 20% * SMC comparison (Fluoropolymer tubing, Series TL/TIL) Roll Color Fluid Note 1) Translucent (material color) Air, Water, Inert gas Fluoropolymer fitting LQ1 series 20C 100C 200C
Compatibility is indicated for fluid temperatures of 200C or less. The material and fluid compatibility check list provides reference values as a guide only, therefore we do not guarantee the application to our product. The data above is based on the information presented by the material manufacturers.
Compatibility is indicated for fluid temperatures of 200C or less. The material and fluid compatibility check list provides reference values as a guide only, therefore we do not guarantee the application to our product. The data above is based on the information presented by the material manufacturers.
Proof pressure D 0 to 150C Nut material PVDF Operating temperature MS 0 to 200C Nut material PFA LQ Withstand Pressure and Heat Resistance Performance Precautions MQR 4.0 T Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions. 3.5 3.0 Piping Caution 2.5 Pressure (MPa) 1.
Table symbols : Can be used Compatibility is indicated for fluid temperatures of 200C or less. Consult SMC regarding fluids other than the above. Consult SMC regarding operating conditions.
Features PFA Super PFA Modified PTFE FEP Material Chemical resistance 260C 260C 260C 200C Heat resistance Flexibility Ion elution Internal smoothness Air, Water, Inert gas Fluid Chemical liquids, Deionized water Chemical liquids, Deionized water 4 to 19 2 to 25 4 to 12 4 to 12 Tubing O.D.
Fluoropolymer Fittings Hyper Fitting/Flare type Series LQ3 Specifications LQ310 LQ320 LQ330 Model Material Max. operating pressure (at 20C) New PFA 1.0 MPa 0 to 150C 0 to 200C 3 to 25 1/8" to 1 1/4" Nut material: PVDF Operating temperature Nut material: PFA Metric Inch Applicable tube size Refer to Best Pneumatics No. 7 for further details.
Nut Tubing support Insert bushing Tubing Before tightening Seal locations Excellent heat resistance The use of a nut with locking mechanism and trapezoidal screw threads maximizes seal performance even when subjected to heat cycles, maintaining integrity up to 200C.
IR Series) 0.020 0.018 0.016 0.014 0.012 0.010 0.008 0.006 0.004 0.002 0.000 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 sliding resistance [MPa] Pressure equivalent to C96SD50-200C Example B Example A Driving roller Winding roller Precision regulator Precision regulator (Moving object) f C96YD50-200C Pressure [MPa] Example B Specifications Precision regulator Made to Order (For details, refer to pages
Proof pressure Operating temperature 0 to 200C Burst Pressure and Heat Resistance Performance 4.0 3.5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3.0 2.5 Pressure (MPa) 2.0 1.5 1.0 0.5 0 20 40 60 80 100 120 140 160 180 200 Temperature (C) 1/8", 3/16", 1/4", 4,
The recommended operating temperature ceiling is 200C. Several variations of Chemraz are available and it is advisable to make a selection based upon the particular plasma being used and other conditions, etc. Chemraz is a registered trade mark of Greene, Tweed & Co.
The recommended operating temperature ceiling is 200C. Several variations of Chemraz are available and it is advisable to make a selection based upon the particular plasma being used and other conditions, etc. Chemraz is a registered trade mark of Greene, Tweed & Co.
There are many types, including perfluoropolyether (PFPE), perfluorocarbon (PFC), hydrofluoropolyether (HFPE), and hydrofluoroether (HFE), but they share the characteristic of high electrical insulation properties, and grades can be selected with appropriate fluidity even at low temperatures, such as 100C, and high temperatures, such as 200C and above.
There are many types, including perfluoropolyether (PFPE), perfluorocarbon (PFC), hydrofluoropolyether (HFPE), and hydrofluoroether (HFE), but they share the characteristic of high electrical insulation properties, and grades can be selected with appropriate fluidity even at low temperatures, such as 100C, and high temperatures, such as 200C and above.