SMC Corporation of America
Elite Part Number Search
Search Results "CXSL20-15-Y7PWSDPC"

N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6 2 Paddle Style Flow Switch Series IF3 Fluid and Ambient Temperature Range Enclosure Open type Using indoors away from water drop.

ZF Flat with ribs (C) Flat style (U) ZP ZP02Ul to 08Ul ZP10Cl to 50Cl ZCU Vacuum related Model Nom.size C10 A 10 B 12 C 4 D 13 E 7.7 F 12 Y 1.7 ZP10Cl ZP13Cl ZP16Cl ZP20Cl ZP25Cl ZP32Cl ZP40Cl ZP50Cl C13 13 15 4 13 7.7 12 1.8 ZP10Ul to 50Ul C16 16 18 4 13 8.2 12.5 1.2 C20 20 23 4 15 9.5 14 1.7 C25 25 28 4 15 9.5 14 1.8 C32 32 35 4 15 10 14.5 2.3 C40 40 43 7 18 13.7 18.5 3.3 C50 50 53 7 18

Refer to p.2.9-15 for How to Order for DIN rail.

AIR EXH FLUID IN Automatically operated type Performance Curve SUP: Pilot air pressure Flow Rate Characteristics Air Consumption 0.5 200 Air consumption (L/min [ANR]) SUP = 0.5 MPa Discharge pressure (MPa) SUP = 0.5 MPa 0.4 SUP = 0.4 MPa 150 SUP = 0.4 MPa 0.3 SUP = 0.3 MPa SUP = 0.3 MPa SUP = 0.2 MPa 100 SUP = 0.2 MPa 0.2 50 0.1 0 0 10 15 20 25 5 0 5 0 10 15 20 25 Discharge flow rate (L/

Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.

h S T TT W Shock absorber model MY1B25 MY1B32 MY1B40 Applicable cylinder Applicable cylinder 4.5 67.3 12 5 (Max. 16.5) 70 RB1412 3.5 46.7 7 5 (Max. 16.5) 60 RB1007 5.5 73.2 15 8 (Max. 20) 90 RB2015 6 4.5 67.3 12 8 (Max. 20) 74 RB1412 5.5 73.2 15 9 (Max. 25) 100 RB2015 4 4.5 67.3 12 9 (Max. 25) 94 RB1412 1194 MY1B Series Mechanically Jointed Rodless Cylinder Basic Type Side Supports Side

White Black Black Red Red Red Black Black White 1 station SOL. 2 stations 2 SOL. 3 3 stations SOL. 4 stations 4 SOL. 5 5 stations SOL. 6 stations 6 SOL. 7 7 stations SOL. 8 stations 8 (a) SOL. 9 9 stations (2) SOL. 10 stations 10 SOL. 11 11 stations (b) (1) Black White SOL. 12 stations 12 SOL. 13 13 stations SOL. 14 stations 14 SOL. 15 15 stations SOL. 16 stations 16 How to Calculate the

Space saving Space saving Actual size 6.5 mm 15 mm The resin silencer is now a more compact size!

(Produced upon receipt of order) Note 2) Minimum stroke available without auto switch or with one auto switch is 15 mm and minimum 25 mm for with 2 auto switches. Note 3) For 2 or more auto switches with stroke less than 25 mm (minimum 15 mm), consider -X431 (2 switch rails).

Standard stroke 6 10 15 20 25 32 40 50 63 6mm 10mm 15mm Port thread type 20mm Bore size 6, 10, 15 Type M thread Rc NPT G Symbol 25mm 32mm Nil 20, 25, 32, 40 40mm TN TF 50, 63 50mm 63mm Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) 300 50, 100, 150, 200 6 500 50, 100, 150, 200, 250, 300 10 15 20 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 1000 1500 100

N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6

Note) D1: Max. diameter 15-3-3 4 Series KR Union Tee: KRT Effective area (mm 2) FR soft nylon FR double layer Applicable tubing O.D.

Refer to Glossary on page 17-3-15 for details of max. operating pressure differential and max. system pressure.

Periodic maintenance or installation of an external air suction filter with a large capacity is recommended. (15) The vacuum pad surface contacting with the workpiece is deteriorated over the number of contact. The workpiece may not be contacted correctly if the surface is deteriorated due to the increase of the rubber viscosity.

0 0 0 5 10 15 20 25 0.2 0.3 0.4 0.5 [MPa] [L/min (AMR) ] Pmax Qmax 10 Pmax 2 (P1 Q1 ) 3 Qmax 0 37 - No.ZQ-OM01401-B 11.2 () ZQ000A 11.3 -100 -80 [kPa] -60 -40 -20 0 (V 6 ) 0 5 10 15 20 [L/min (AMR) ] ZQA (PD)() ZQ000A (PD) 100 80 [L/min(ANR)] 70 [L/min(ANR)] 0.5MPa 0.5MPa 80 60 0.4MPa 50 0.35MPa 0.3MPa 60 0.3MPa 40 40 30 20 20 10 0 0 0 1 2 3 4 5 0 1 2 3 4 5 [] [] ZQA (PD)()

IDU Series 14-3 How to perform maintenance 14 2 IDX-OM-W022 Air Dryer 14 Service Record 15 Service Record 15-1 Service Record It is recommended to keep a maintenance/service record. Parts No.

(Ex.) 1. 2. 3. 4. 14-2 IDU8E/11E/15E1-23-V IDF-S0198 1.6MPa AC230V10% (50Hz) ON 0.5sec OFF 30 IDU Series 141 IDX-OM-W023 14 V 14-3 1) 2) 3) 4) ON OFF 4 6 2 3 8 4 2 1 10 0.5 5 0.5 ON:SEC OFF:MIN 14-4 1-1 IDU Series 142 IDX-OM-W023 15 15 15-1 / IDU Series 15-1 A2020/1 B2021/5 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Tel: +81 3 5207

Tightening torque (Nm) Wrench tightening angle after tightened by hand (deg) Warning Uni thread size 1/8 30 to 60 3 to 5 1/4 30 to 60 8 to 12 3/8 15 to 45 14 to 16 1/2 15 to 30 20 to 22 Connection Female Thread : G Wrench tightening angle after tightened by hand (deg) Tightening torque (Nm) Uni thread size 1/8 30 to 45 3 to 4 1/4 15 to 30 4 to 5 3/8 15 to 30 8 to 9 1/2 15 to 30 14 to 15 2