SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S32H-6000"

For Air (Orifice size: 10 mm, 15 mm, 20 mm, 25 mm) How to read the graph The sonic range pressure to generate a flow rate of 6000 l/min (ANR) is P1 0.57 MPa for a 15 orifice (VXD214 -03) and P1 0.22 MPa for a 20 orifice (VXD215 -06).

Example: 3) From Table 2, determine Stop Tube Requirements ~ 1) From Table 1, determine Stroke Factor (SF) ~ NCDA1L800-6000-XTATCDN Find L length and note Stop Tube length Stroke Factor 2.0 8 Bore Stop Tube Length = 8 60 Stroke 2) Determine Effective Length L MS1 Mount L = Stroke x Stroke Factor Supported but not rigidly guided = 60 x 2.0 = 120 inches 21 Engineering Specifications Expanded

. *3 Double clevis type: Use within the stroke limit of 400 or less and the thrust limit of 6000 or less.

Example 1: Assuming Pn20E = 4, Pn210 = 1, maximum motor speed = 6000 [min-1], encoder resolution = 1048576 (20 bits): 1/4 6000/60 1048576 0.00025 = 6553.6 [reference units] The upper limit for the backlash compensation is 6553.6 [reference units].

How to Order IZS31 CP X13 L (Tolerance 1%) Cable length 60 L: Cable length Symbol 7 01 02 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19 20 1000 mm 2000 mm 4000 mm 5000 mm 6000 mm 7000 mm 8000 mm 9000 mm 11000 mm 12000 mm 13000 mm 14000 mm 15000 mm 16000 mm 17000 mm 18000 mm 19000 mm 20 mm (Red) 1 12 (6.2) 3 Cable Specifications No. of cable wire 12 0.14 mm2 (AWG26) 0.48 mm Nominal cross section

Standard Stroke Bore size (mm) Standard stroke (mm) Manufacturable Note) maximum stroke (mm) 6 300 50, 100, 150, 200 10 500 50, 100, 150, 200, 250, 300 50 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 6000 63 Note) Please contact SMC if it is used by exceeding the maximum stroke length.

HRS100-A/W-20/40, HRS150-A/W-40 4 h 2 h 1 h 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Operating time 20 s 30 s 10 s Max. 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 5000 6000 7000 10 1500 Current (% for chiller main breaker volume) 123 HRS100/150 Series Specific Product Precautions 5 Be sure to read this before handling

Current (% for chiller main breaker volume) HRS100-A/W-20 4 h 2 h 1 h 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Operating time 20 s 30 s 10 s Max. 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 5000 6000 7000 10 1500 Current (% for chiller main breaker volume) 28 Series HRS100/150 Specic Product Precautions 5 Be sure to

Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 -19No.EX-OMN0028-B Setting and Adjustment Switch setting (1)Loosen the display cover screw (indicated by arrow). (2)Open the display cover using a flat head screwdriver, etc. (3)Set the switch using a small watchmaker's screwdriver with a thin blade, referring to the setting

Improved sealing Models and Specifications Note 1) Pneumatic cylinder Hydraulic cylinder Operating pressure Ambient temperature Applicable cylinder nominal thread size Allowable eccentricity U Max. tension and compression N 80 210 1100 2500 6000 11000 Applicable cylinder bore size (mm) 10 10, 16 20 25, 32 40 50, 63 Model M4 x 0.7 M5 x 0.8 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 0.5 0.5 0.5

Example 1: Assuming Pn20E = 4, Pn210 = 1, maximum motor speed = 6000 [min-1], encoder resolution = 1048576 (20 bits): 1/4 6000/60 1048576 0.00025 = 6553.6 [reference units] The upper limit for the backlash compensation is 6553.6 [reference units].

memory address for setting Item Setting value Default (Note2) value QD77MS2 QD77MS4 QD77MS16 00: Positioning complete Da.1 Operation pattern 01: Continuous positioning control 11:Continuous path control a Da.2 Control system b (Note 1) b 0:Pr.9 Acceleration time 0 1:Pr.25 Acceleration time 1 2:Pr.26 Acceleration time 2 3:Pr.27 Acceleration time 3 Da.3 Acceleration time No. c 0H 2000+ 6000n 6000

. -30 -20 -10 0 0 1000 2000 3000 4000 5000 6000 Piping length [mm] mm Fig. A. Vacuum pressure for piping (ZK215) Tube TU0805 or T0806 Tube TU1065 or T1075 Nipple KQ2N08-99 Straight type of different diameter KQ2H08-10A Fig. B Example of piping -74No. ZK2-OM01301 In addition, the exhaust port should not be blocked or pressurized.

Improved sealing Models and Specifications Note 1) Pneumatic cylinder Hydraulic cylinder Operating pressure Ambient temperature Applicable cylinder nominal thread size Allowable eccentricity U Max. tension and compression N 80 210 1100 2500 6000 11000 Applicable cylinder bore size (mm) 10 10, 16 20 25, 32 40 50, 63 Model M4 x 0.7 M5 x 0.8 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 0.5 0.5 0.5

The motor was rotated exceeding the maximum permissible speed at power failure (6000 r/min) by an external force during driver power off. (Note: The acceleration time is 0.2 s or less.) Check if the motor was accelerated suddenly to 6000 r/min by an external force. Extend the acceleration time.

Also, as a guide for periodically replacement, the operation hours is 6000 to 8000 hours. (normally 1 year) Note 2) Note 1) In the case of the HRG001/002, because the pump included in the unit is a magnet pump with no rotating shaft seal, it is not necessary to inspect the mechanical seal (rotating shaft seal).

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours.

For Air (Orifice diameter: 10 mm, 15 mm, 20 mm, 25 mm) How to read the graph The sonic range pressure to generate a flow rate of 6000 L/min (ANR) is as follows.

8000 2000 10 0 4000 6000 8000 2000 10 0 4000 6000 8000 2000 10 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) Pressure Characteristics (Representative values) Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 L/min (ANR) AC25-B AC20-B AC10-A 0.3 0.25 0.25 Set point Set point Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.25

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours. Leakage was found here Fig. 8-3 Check for water leakage from pump 8.2 Inspection and Cleaning HRS090 Series 8-6 HRX-OMT002 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection during winter season Keep the power supply ON for these functions.