) Max. operating pressure (at 20C) 0.8MPa 1.5MPa Refer to series TU burst pressure characteristics curve.
The resistance of the solenoid valve is R 20 + 278 3% Ohm at 68F (20C). Do not bend or pull cables repeatedly. T4 Maximum surface temperature 275F (135C) Temperature class Hazardous Locations Specifications Terminal type (TT) L-type plug connector (L) LL-type plug connector (LL) Warning Electrical entry Note) 1.
(at 20C) Data 10-12-9 9 Series CEP1 Proper Auto Switch Mounting Position Weight (Without mounting bracket/connector) (kg) Regarding dimensions for the proper auto switch mounting position (at stroke end), refer to page 1012-16.
degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Solenoid Coil Specifications Note) The values are for an ambient temperature of 20C and at the rated voltage.
Fluid viscosities shown are at room temperature (17C to 20C). Flow coefficient: When 100% of water flows at 1 mm2/sec, the flow coefficient indicates that 85% flows at a kinematic viscosity of 100 mm2/sec. Flow rate (L/min) 50 A Bag Filter FGF Series Construction FGF1 FGF3-40 FGF5-60 Air release Nut Air release valve Pin q FGD Davit for cover Spring washer t u !
1 50F (10C) 68F (20C) 86F (30C) Standard model Set dew point (Normal operation) Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 50 to 86F(10 to 30C). 2. Normal operation (ECO LED is OFF): Dew point is fixed to 50F (10C).
Refrigerant HFC134a JIS Symbol Auto drain AD38 AD37 AD48 Port size 3/8 1/2 3/4 (kg) Weight 16 18 23 28 17 22 27 Refrigerated air dryer Body panel: White 1 (Munsell 10Y8/0.5) Base: Gray 2 (Munsell 10Y5/0.5) Coating color Auto drain Applicable air compressor output (Guide) In the case of a screw type (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 Note 1) The data for l/min (ANR) is under the conditions of 20C
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) When operating the locking type manually, apply torque of 0.2 Nm or less. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Response time (DC) (ms) Note 1) ON: 5 or less OFF: 4 or less 20 Max. operating frequency (Hz) Manual override Non-locking push, Locking slotted Not required Lubrication Unrestricted Mounting position Impact/Vibration resistance (m/s2) Note 2) 150/30 Dust proof Enclosure Note 1) Based on dynamic performance test JIS B8374-1981 (standard type: at coil temperature of 20C, with rated voltage,
Flow at 20C, atmospheric pressure, and 65% of relative humidity . -8- 4.
(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.
(Coil temperature: 20C, at rated voltage, without surge suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
the slave at the trunk end is connected in T branch, it is necessary to connect terminal resistance by the cable longer than length of stay branched from trunk so that the terminal resistance would be positioned the most far from master. 6-3 Cable for communication line Type Specification Vinyl code VCTF JIS C3306 2 cores, Nominal section 0.75mm2 (Signal line 2) Conductor resistance(at 20C
Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa 2 mounting types Ambient and fluid temperature Without auto switch: 20C to 80C (No freezing) With auto switch: 10C to 60C (No freezing) Front side mounting and bottom side mounting available to suit your applications.
Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
Note2) Conditions that radiating water temperature is at 20C, radiating water flow rate is at 5 L/min, setting temperature is at 20C and ambient temperature is at 20C Note3) External sensor should be prepared by customers. Note4) Reservoir cap, Handle, Drip proof cover, connector are not included.
M km, 20C 5m VVZS3000-21A-3 x 24AWG * For other commercial connectors, use a 25-pole female connector made in conformity with MIL-C-24308.
Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).