type (Except for 6) Single clevis type (Non-integrated type) Double clevis type 10 15, 30, 45, 60, 75, 100 16 15, 30, 45, 60, 75, 100 20 15, 30, 45, 60, 75, 100 25 15, 30, 45, 60, 75, 100 Strokes are available in 1mm increments by installing spacers in standard stroke cylinders.
Display/set pressure range -2.5 to 52.5 MPa Display/min. set unit 0.1 MPa Proof pressure 75 MPa Power supply Used as switch output device 12 to 24 VDC 10% with 10% voltage ripple or less voltage Electric spec.
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
Single 20 or less VFR2100 VFR2110 1 8 1 4 10 Double 20 or less VFR2200 VFR2210 1 8 1 4 1 8 1 4 1 8 1 4 Closed center 5 30 or less VFR2300 VFR2310 0.43 (0.45) Exhaust center 5 30 or less VFR2400 VFR2410 0.43 (0.45) Pressure center VFR2500 VFR2510 5 30 or less Note 1) [ ]: Denotes the normal position.
Standard Strokes Standard strokes (mm) Bore size (mm) 20 32 40 50 63 80 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 JIS symbol 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Double acting/Double rod 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25,
The set value can be copied to up to 10 switches simultaneously.
Bonnet assembly/Part indication number (1) Temperature specifications Indicator Valve size 16 25 40 50 General use Without XLA16-30-1-2 XLA25-30-1-2 XLA40-30-1-2 XLA50-30-1-2 With XLA16A-30-1-2 XLA25A-30-1-2 XLA40A-30-1-2 XLA50A-30-1-2 High temperature Without XLA16-30-1H-2 XLA25-30-1H-2 XLA40-30-1H-2 XLA50-30-1H-2 With XLA16A-30-1H-2 XLA25A-30-1H-2 XLA40A-30-1H-2 XLA50A-30-1H-2 Temperature
/N.O.) 2(B) 4(A) C Note 2) L-type plug connector with cover Lead wire length Symbol 3 6 10 15 20 30 100 Lead wire length 300 mm Note LL 5(EA) 3(EB) 1(P) Note 1) 3-position type is not available for the 53-SY9000 series.
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
A-coded (Normal key) 30 5 50 40.7 27 30 5 50 10 25.3 Socket connector pin arrangement A-coded (Normal key) 10 Item Specifications Cable O.D. 6 mm Item Specifications Cable O.D. 6 mm Conductor nominal cross section 0.3 mm2/AWG22 Conductor nominal cross section 0.3 mm2/AWG22 Wire O.D.
9 1/2 15 to 30 14 to 15 2) The gasket can be reused up to 6 to 10 times.
For 3 port (2 stations, one-piece type) 254 g For gate valve 300 g For 2 port 409 g End plate For 3 port 495 g For 2/3 port mixed mounting 452 g 24 g 6 25 g 8 VCKH 33 g 10 36 g 12 25 g 6 26 g 8 VCKK Fittings 32 g 10 37 g 12 29 g 6 30 g 8 VCKL 37 g 10 41 g 12 10 Valve for Water and Chemical Base Fluids VCC Series Dimensions Mounting hole dimensions (When valve is built in to the device.)
Speed[mm/s] Stroke Range 701 to 800 20 to 550 12 to 330 6 to 180 3 to 90 24 to 750 16 to 500 8 to 250 4 to 125 30 to 1140 20 to 760 10 to 350 5 to 175 801 to 900 24 to 610 16 to 410 8 to 200 4 to 100 30 to 930 20 to 620 10 to 280 5 to 140 Actuator specification 901 to 1000 24 to 500 16 to 340 8 to 170 4 to 85 30 to 780 20 to 520 10 to 250 5 to 125 1001 to 1100 30 to 660 20 to 440 10 to 220
No.SFOD-OMT0009CN-B LEFS40 H A B [mm] 30 20 10 [mm] 1200 1000 1100 1200 1000 1100 1200 [mm/s] 500 500 410 340 250 200 170 [mm/s] 30 20 10 () [mm/s] 49 33 17 () 1.3 LES(H) LES(H)8 LES(H)16 LES(H)25 J K J K J K [mm] 8 4 10 5 16 8 [mm/s] 400 200 400 200 400 200 [mm/s] 20 10 20 10 20 10 () [mm/s] 25 13 27 14 30 15 () 1.4 LEP LEP*8 LEP*16 J K J K [mm] 8 4 10 5 [mm] 25 25 [mm/s] 300 250
or more 38 or more 39 or more 56 or more 58 or more 70 or more 76 or more 82 or more 118 or more 144 or more 16 or more 20 or more 24 or more 30 or more 32 or more 40 or more 50 or more 48 or more 60 or more 64 or more 80 or more 3.2, 1/8" 4, 5/32" 3/16" 6 1/4" 8, 5/16" 10 3/8" 12 1/2" 16 T 28 to 30 NPT, R 1/2 28 to 30 NPT, R 3/4 36 to 38 NPT, R 1 40 to 42 NPT, R 1 1/4 48 to 50 NPT, R 1
moment 70 MXW25 70 100 50 30 40 N m 50 MXW20 Pitch moment Yaw moment Roll moment 25 30 40 MXW20 Model 20 Moment N m Moment N m Mp/Mep My/Mey Mr 15 MXW16 20 MXW16 12 5 5 3 MXW 8 10 15 7 10 MXW12 MXW12 10 10 6 MXW12 4 5 7 5 4 3 20 20 12 MXW16 MXW8 MXW8 3 2.5 40 40 25 MXW20 2 110 110 65 2 1.5 MXW25 50 100 200 300 500 700 50 100 200 300 500 Piston speed mm/s Piston speed mm/s (Graph3) (Graph2
SMC SMC 6 20 10 Pitch = 21 10 10 10 L2 L1 L3 Body (Air operated type) (ZX1A) Pressure setting trimmer 9.3 13 Vacuum switch ZSE2 14.5 M5 x 0.8 (Pilot port) Filter A: Release flow rate adjusting needle with lock nut Adapter B 6 44 M5 x 0.8 (External release port) Silencer + Ejector 30 22 47 37.4 8 Adapter D 57.4 (Needle fully open) Individual spacer ZX1-R1 70.3 Release valve (VJ314) (Normally
3.67 5.82 8.94 Temprature "F 32 30 20 l0 0 -10 -20 -30 40 s/fC (Shndard) .t37 I t A .083 .053 .033 .020 .ot2 .007 .004 g/ft' (Atmospheric) .r37 .177 .085 .056 .036 .023 .014 .009 .005 Tabla 3.7 Water Saturation of Air (Dew Point) The term g/tf standard rfers to a volume at gzoF. At BooF it.s volume is extended to l+ (80-32) or l.i tf 459?
1.0 0.05 (10) 0.5 (70) MPa, psi 0 to 30 0 to 0.2 0.01 (2) 0.1 (14) R 1/8, 1/4 0 to 60 0 to 0.4 0.02 (4) 0.2 (28) 0 to 150 0 to 1.0 0.05 (10) 0.5 (70) Note 1) Do not apply pressure more than the maximum display pressure.
30 29.5 30 32 15.2 18.5 8 14 Applicable tubing 40 49 14 21 27 20.3 31 18.5 20.6 10 Connection thread (With seal) 63 22 39 30.8 34 25.2 17 1 2 KRV12-04S 20.9 33.5 80 12 Reference dimensions after R thread installation.