)) Relief flow rate (L/min (ANR)) IR1010-01 IR1010-01 IR1010-01 Back pressure: 0.7 MPa Supply pressure: 0.7 MPa 0.4 0.204 0.7 Set pressure P2 (MPa) Set pressure P2 (MPa) Set pressure (MPa) 0.6 0.202 0.3 0.5 Set point 0.4 0.200 0.2 0.3 0.198 0.2 0.1 0.1 0.196 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 40 80 120 160 200 0 50 100 150 200 250 300 350 Flow rate (L/min (ANR)) Supply pressure P1

x 10 x 10-3 = 0.08 (Nm) Load factor 3 = M2 M2 max = 0.08 0.8 = 0.1 M2 8-14-12 12 Mechanically Jointed Rodless Cylinder Series MY3A/3B Calculation of Guide Load Factor 4.

Load factor 1 = m3 / m3 max = 7.025 / 22.5 = 0.31 m3 M2: Moment Z M2 max (from 2 of graph MY2H / M2) = 19.5 (Nm) . M2 = m3 x g x Z = 7.025 x 9.8 x 37.8 x 103 = 2.60 (Nm) Load factor 2 = M2 / M2 max = 2.60 / 19.5 = 0.13 m3 M2 5 Series E-MY2 Selection Example cont. X M3: Moment M3 max (from 3 of graph MY2H / M3) = 19.5 (Nm) .

max. m1 max. m3 max. m2 max. m1 max.

Set value input mode Press the "SET" button to display "P1-20" 1. The output OUT1(1) set value input mode is selected. 1: If the set value of P1 is -20) 2. OUT1(1) set value input Pressing the button increases the set value. Pressing the button decreases the set value. Press the "SET" button to save the set value and select the output OUT1(2) set value input mode.

ISE When the values of P1 and P2 are the same or when P1>P2 within three digits, the hysteresis will be automatically three digits for the set value of P1. Window comparator mode: ZSE The hysteresis is two digits, so separate P1 from P2 by five digits or more and set them.

External Pilot Adiabatic Space Caution Caution Piping of pilot port (P1, P2) P1 and P2 piping should be as follows according to the model. There is a space between body and cover (: approximate 1 mm) for adiabatic effect.

Coordinates and Moments z M3: Yawing M1: Pitching y x M2: Rolling Static moment Ceiling mounting Horizontal mounting Wall mounting M1 M2 M2 M1 M2 M3 y X x Y y z X x Y X x Z m1 x g m2 x g m3 x g Vertical mounting Mounting orientation Horizontal Ceiling Wall Vertical m1 m2 m3 m4 Static load m M3 M1 m1 x g x X m2 x g x X m4 x g x Z Static moment M1 m1 x g x Y m2 x g x Y m3 x g x Z y z M2 z Y

X m3 x g m2 x g Vertical mounting Mounting orientation Horizontal mounting Ceiling mounting Wall mounting Vertical mounting M3 Static load (m) m1 m2 m3 m4 Note) M1 Static moment M1 m1 x g x X m2 x g x X m4 x g x Z z y M2 m1 x g x Y m2 x g x Y m3 x g x Z Y Z M3 m3 x g x X m4 x g x Y m4 x g Note) m4 is a mass movable by thrust.

Static moment M2 = m x g x L1 = 0.5 x 9.8 x 0.05 = 0.245 [Nm] 2 = M2/M2 max = 0.245/3 = 0.082 Investigate M2. M1 and M3 are not required because they are not generated.

Static moment M2 = m x g x L1 = 0.5 x 9.8 x 0.05 = 0.245 [Nm] 2 = M2/M2 max = 0.245/3 = 0.082 Investigate M2. M1 and M3 are not required because they are not generated.

M2max (from 3 of graph MY1MW: M2) = 24 (Nm) m1 M3 = m1 x g x Y = 6.525 x 9.8 x 29.6 x 10 3 = 1.89 (Nm) Load factor 3 = M2/M2max = 1.89/24 = 0.08 M2 MX 5.

Static moment M2 = m x g x L1 = 0.5 x 9.8 x 0.05 = 0.245 [Nm] 2 = M2/M2 max = 0.245/3 = 0.082 Investigate M2. M1 and M3 are not required because they are not generated.

: Rolling Static Moment Ceiling mounting Horizontal mounting Wall mounting M1 M2 M3 M1 M2 y M2 X x Y z y m1 x g X Z Y m3 x g x X x m2 x g Vertical mounting Mounting orientation Horizontal mounting Ceiling mounting Wall mounting Vertical mounting m1 m2 m3 m4 Note) M3 Static load (m) M1 M1 m1 x g x X m2 x g x X m4 x g x Z Static moment z y Y M2 m1 x g x Y m2 x g x Y m3 x g x Z Z M3 m3 x g

Static moment M2 = WL1 = 100.2 = 2 [Nm] 2 = M2/M2 max = 2/16 = 0.125 W = 1 [kg] = 10 [N] W Review M2. Since M1 & M3 are not generated, review is unnecessary. M L1 3. Dynamic moment We = 5 x 10-3WgU = 5 x 10-319.8300 = 15 [N ] Me3 = 1/3We(L2-A) = 1/3150.182 = 0.91 [Nm] 3 = Me3/Me3max = 0.91/10 = 0.091 Me3 Guide central axis We W L2 Review Me3.

Red LED is flashing EtherNet/IP connection time out Red LED is ON IP duplicated OFF BUS IN side (P1): No Link, No Activity L/A1 Link/Act Green LED is ON BUS IN side (P1): Link, No Activity Green LED is flashing BUS IN side (P1): Link, Activity OFF BUS OUT side (P2): No Link, Activity L/A2 Link/Act Green LED is ON BUS OUT side (P2): Link, No Activity Green LED is flashing BUS OUT side (P2)

VVFS2000-22A-1 VVFS2000-22A-2 Cylinder pressure Check valve G E T D Applicable valve model VFS2400-F VFS2410R1 Solenoid one side energized 210 or less P R2 Piston SUP side pressure (P1) Leakage (cm2/min) R1 210 or less P Solenoid both sides de-energized SUP side pressure P1 (MPa) R2 0 A R1 Operating range B R2 Supply pressure: 0.5 MPa Double check spacer Caution In the case of 3 position

For saturated steam Viewing the graph [664] (183) Upstream pressure of valve P1 = 1.0MPa 1.0 The sonic range pressure to generate a flow rate of 25kg/h for orifice 3 (VCS21) is P1 approx. 0.68MPa for orifice 4 (VCS21) is P1 approx. 0.40MPa for orifice 5 (VCS21) is P1 approx. 0.29MPa The holding heat differs somewhat depending on the pressure P1, but at 25kg/h it is approximately 16000kcal

Applying the same pressure to P1 and P2 is recommended when restarting.