SMC Corporation of America
Elite Part Number Search
Search Results "XLD-50-M9PLA"

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light & Surge Voltage

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: L (w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface), Version: Legacy, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector)

Valve Type: Double Acting, Bellows Seal, Flange Size: 50, Flange Type: KF (NW), Valve Direction: w/o Indicator, Left Flange Surface; Std. Indicator, Left Flange Surface, Auto Switch: M9P--Solid State, Gen.

Valve Type: Double Acting, O-ring Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: -, Valve Action: 2 position single

Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/Indicator, Left Flange Surface, Version: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard Indicator

Valve Type: Normally Closed, O-ring Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Version: Legacy, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 63, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 150°C, with 80°C at 100VAC, 100°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, Flange

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, Flange

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 80, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface; Std.

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 63, Flange Type: D [K(DN)], Port Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Left Flange Surface; Std. Indicator, Left Flange Surface, Temperature: 5 to 150°C, with 80°C at 100VAC, 100°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Left Flange Surface; Std. Indicator, Left Flange Surface, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement