1 operation A Contact output signal 1 selected alarm ---(AL.01)*8 Contact output signal 2 function RMT Contact output signal 2 operation A Contact output signal 2 selected alarm ---(AL.01)*8 Contact output signal 3 function ALM Contact output signal 3 operation B Contact output signal 3 selected alarm ---(AL.01)*8 *7: For more details of the default settings, refer to 5.22 Alarm Customizing
Valve diagnostics 1 . 5-4 Valve diagnostics 1 Bit 0 Valve 0, 1 diagnostics 01() 1 Valve 2, 3 diagnostics 01() 2 Valve 4, 5 diagnostics 01() 3 Valve 6, 7 diagnostics 01() 4 Valve 8, 9 diagnostics 01() 5 Valve 10, 11 diagnostics 01() 6 Valve 12, 13 diagnostics 01() 7 Valve 14, 15 diagnostics 01() 5.1.1.4.
Canevaro 752, Lince, Lima, Peru TEL: 1-471-6002 FAX: 1-471-0935 IRELAND SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. Galicia 1650 esq.
---(AL.01)6 selected alarm 1: The default setting when CO02 is PRO1 or PRO2. 4: The default setting when CO23 is A.SEL. 2: The default setting when CO15 is SW-A or SW-B. 5: The default setting when CO26 is A.SEL. 3: The default setting when CO19 is SW-A or SW-B. 6: The default setting when CO29 is A.SEL.
1 Direct Operated Solenoid Valve Metal Seal Series VS4 10 Model Flow characteristics Max. (1) operating cycle (cpm) (3) VK Response (2) time (ms) Weight (kg) Model Port size Rc (Nominal size) Number of positions JIS Symbol P A/B A/B EA/EB VZ C [dm 3/(sbar)] C [dm 3/(sbar)] b b Cv Cv AC DC AC DC AC DC VS4110-01 (6A) 3.2 3.2 0.42 0.37 0.86 0.80 1 8 2 (Single) 1,200 180 13 or less 45 or less
3/8 5 AF4000 1/4, 3/8, 1/2 Float style auto drain AF4000-06 3/4 Pressure differential auto-drain 3/4, 1 AF5000 AF6000 1 Mist Separator Series AFM AFM2000 1/8, 1/4 Bracket AFM3000 1/4, 3/8 0.3 Float style auto drain AFM4000 1/4, 3/8, 1/2 Pressure differential auto-drain AFM4000-06 3/4 Micro Mist Separator Series AFD AFD2000 1/8, 1/4 Bracket AFD3000 1/4, 3/8 0.01 Float style auto drain AFD4000
2 3 4 5 6 Forward Run Prohibited Pn50A.3 7 8 L /P-OT 9 A B C D E F H N-OT 0 1 2 3 4 5 6 Reverse Run Prohibited Pn50B.0 7 8 L /N-OT 0 A B C D E F L /P-CL 0 1 2 3 4 5 6 Forward External Torque Limit Pn50B.2 8 7 H P-CL 9 A B C D E F L /N-CL 0 1 2 3 4 5 6 Reserve External Torque Limit Pn50B.3 8 7 H N-CL 9 A B C D E F L /DEC 0 1 2 3 4 5 6 Homing Deceleration LS Pn511.0 8 7 H DEC 9 A B C D E F
01 02 M5 1/8 (6A) 1/4 (8A) Electrical entry G-Grommet Orifice size N.O.
side of A port Nil 1 8 01 Rc VFN Nil Rc G NPT NPTF C4 4 cassette P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 F N T Same side of A port S C6 6 cassette Valve stations Type S42 (Solenoids on the same side of A port) 01 1 station 20 20 stations P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve
Regulator for 2 MPa Option None Nil Regulating pressure range B 1348112 G361001 G461002 G36401 G46402 G36P10N01 G46P10N02 G36P4N01 G46P4N02 1348110A Bracket ARX20 Nil F 0.05 to 0.85 MPa 0.05 to 0.30 MPa 0 1 ARX21 Nil F Note 1) Thread type (2) G Pressure gauge ARX20N Rc NPT G Nil N F ARX21N P Port size Panel nut 01 02 1/8 1/4 Option combination numbers Panel nut is also included with B
1 5 Port Air Operated Valve Series VFA3000 How to Order SA Thread type (Including pilot port) VA Nil F N T Rc G NPT NPTF SA Port size (P, A, B port) VA 01 02 1 8 1 4 Option R1, R2 port are 1/8.
Canevaro 752, Lince, Lima, Peru TEL: 1-471-6002 FAX: 1-471-0935 IRELAND SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. Galicia 1650 esq.
A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
A L 3 7 # 0 0 P B 1 0 P B 1 1 P B 1 2 P B 1 6 S p d 0 0 1 Point table error details For the point table No.1 speed data error Point table No. with error Error item Spd: speed Acc: acceleration time constant Dec: deceleration time constant 15 113 16. SERVO MOTOR 16.
A L 3 7 # 0 0 P B 1 0 P B 1 1 P B 1 2 P B 1 6 S p d 0 0 1 Point table error details For the point table No.1 speed data error Point table No. with error Error item Spd: speed Acc: acceleration time constant Dec: deceleration time constant 15 113 16. SERVO MOTOR 16.
Canevaro 752, Lince, Lima, Peru TEL: 1-471-6002 FAX: 1-471-0935 IRELAND SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. Galicia 1650 esq.
Equipment L or R shows the left or right of the filter IN when viewed from front. 100 200 50 l /min (ANR) 200 l /min (ANR) Port size Thread type B (ZFA100) 1 8 1 4 02 01 ZFA200 B (ZFA200) Nil T Rc NPTF F G How to Order Manifold JIS Symbol Indicate both the symbols for air suction filter and bracket for manifold.
DI2 DI1 DI0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 7 (b) Incremental value command system 1) Point table Set the point table values by using set up software(MR Configurator2TM) or the operation section. Set the position data (target position), servo motor speed, acceleration time constant, deceleration time constant, dwell and auxiliary function in the point table.
_ _ 1 A 346 _ _ 0 B 818 _ _ 1 B 333 _ _ 0 C 750 _ _ 1 C 321 _ _ 0 D 692 _ _ 1 D 310 _ _ 0 E 642 _ _ 1 E 300 _ _ 0 F 600 _ _ 1 F 290 7 8 7.
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.