AMR 4 0 00 02 E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)

Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the

PA 02 200 VAC 50/60 Hz 01 100 VAC 50/60 Hz 08 48 VAC 50/60 Hz 01 02 03 04 07 08 05 06 002 Applicable valve model No. 13 24 VAC 50/60 Hz VXZ22 VXZ23 03 110 VAC 50/60 Hz 23 440 VAC 50/60 Hz PAX 003 AC 04 220 VAC 50/60 Hz 51 6 VDC Coil combination code 05 24 VDC 53 48 VDC PB 06 12 VDC 55 100 VDC 56 110 VDC (Refer to the table below.) 07 240 VAC 50/60 Hz DC Note) The voltage codes

Rc3/8 04 Rc1/2 T03 3/8NPTF T04 1/2NPTF 10 10mm Tube 12 12mm Tube 02 Rc1/4 03 Rc3/8 T02 1/4NPTF T03 3/8NPTF Courtesy of Steven Engineering, Inc. !

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing May, 2000 D-SMC.L.A. P-80 (D)

Model Operating Conditions Plate non-rotating accuracy () Allowable plate rotation torque (T) Allowable lateral load (F) Non-rotating accuracy () Torque (Nm) Stroke 50 75 100 125 150 175 200 Load (N) Stroke 50 75 100 125 150 175 200 0.09 42 2.87 42 2.47 40 2.17 + 42 2.38 32 2.16 24 1.98 17 1.82 F T F Refer to page 304 for deflection data. 234 27 Courtesy of Steven Engineering, Inc.-230

Frequency (Hz), Remote controller IZS40 IZS41 IZS42 Remote controller Remote controller 0 1 2 3 4 5 6 7 8 9 1 3 1 0.1 5 3 0.5 8 5 1 10 10 3 15 15 5 20 20 10 30 30 15 DC+ DC+ 20 DC DC 30 Set when remote controller is used. 429 IZS40/41/42 Series Wiring Circuit/IZS41, 42 NPN specification Shield Ionizer (IZS41, 42) Green F.G. Ground with a ground resistance of 100 or less.

Description Material 1 Rod Cover Aluminum alloy NCA200-02AQ3609-S NCA200-03-Q3609-S NCA250-02AQ3610-S NCA250-03-Q3610-S NCA325-02AQ3611-S NCA325-03-Q6311-S 2 Head Cover Aluminum alloy 3 Cylinder Tube Aluminum alloy Please See below for How to order Cylinder Tube 4 Piston Rod Carbon steel Available only as an Assembled Item.

Parl No. naq. 1A MB aO20.03 tg Ba &2041 1C MB 4@1-03 lD MB12-O3 121 Manlfold Block #.{1 Mrnlfold Slock *23 Manlfold Block ,28 Manltold Block l{ol} Us lor mountlno NVS ln24 valvs.

25 5, 10 Rear Flange L1 Without auto switch A 26 26 32 35.5 With auto switch A 31 31 42 45.5 Bore (mm) Stroke range (mm) FD FT FV FX FZ L Inch Metric 14 15.5 18.5 22.5 B 17 17 19.5 22.5 B 22 22 29.5 32.5 11.5 11.5 12.5 14.5 12 16 20 25 4.5 4.5 6.6 6.6 5.5 5.5 8 8 25 30 39 42 45 45 48 52 55 55 60 64 3.5 3.5 4.5 5 5, 10 Double Clevis Without auto switch With auto switch A 40.5 41.5 51 57.5

Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.

R S AMR 4 0 00 02 E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)

JIS Symbol How to Order VR 12 1 06 0 F Body size Applicable tubing diameter Metric size Inch size 1 2 1/8 standard 1/4 standard 23 04 06 08 10 3.2 01 03 07 09 11 1/8" 5/32" 1/4" 5/16" 3/8" 4 6 8 10 Shuttle valve With One-touch fittings For 3.2, use 1/8" tubing. 5-7-5 63 Series VR1210F/1220F Example of Operating Circuit OR circuit Self-hold circuit Interlock circuit When either A or B is

Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.

For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire

Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.

For air VV2CA3-05 VCA35-5G-4-03 1 set Manifold part no. 5 sets Valve part no. (Stations 1 to 5) IN port direction Side Front Nil A Series is the symbol for assembly. Add an in front of the part numbers for solenoid valves, etc., to be mounted. 3 4 Class 3 Class 4 Enter together in order, countingfrom station 1 on the D side.

Gun Type Ionizer IZG10 Series IZS40/41/42 IZT40/41(-L)/ 42(-L)/43(-L) IZN10E IZF IZG10 ZVB IZD10/IZE11 IZH10 Antistatic Equipment *1 Lightweight 200 g Only *1 Body weight Lighting LED Reduced operating force Easy to hold grip Blow setting function p. 179 Select from continuous blow or pulse blow.

Tel :03-3502-2740 Fax:03-5251-7240 August 1996, 14(RP)