VR D E F G J K C 18 1(P) 2(A) 4 4 VHK-04F-04F VHK-06F-04F VHK-06F-06F VHK-08F-06F VHK-08F-08F VHK-10F-08F VHK-10F-10F VHK-12F-10F VHK-12F-12F 31.5 21.8 17.5 3 port valve 41 3.5 1 27 22 26 47.6 23.8 23.8 16.5 15.8 15.8 11 3.4 1.2 15 VHK-B1A 44.5 14.5 16.5 VH 18 6 4 6 41 48 48.6 24.3 23.7 16.5 3.5 16.8 15.8 11 5.1 1.2 15 16 VHK-B1A 44.5 14.5 1 27 22 16.5 26 24.3 16.8 7.2 18 8 6 8 41 50.5 52.4

65.2 32.6 32.6 16.5 3.5 11 57 30 8.6 1.2 VHKlR-02S-02S 18 41 78 39 39 16.5 3.5 11 66 47 9.7 1.2 VHKlR-03S-03S 22 46 88.6 44.3 44.3 21.5 4 14 76 72 16.1 3.2 VHKlR-04S-04S 22 46 97.4 48.7 48.7 21.5 4 14 81 101 17.5 3.2 S (Width across flats) Bracket mounting dimensions T (Width across flats) Connection thread R(PT) Model Bracket assy No.

Rod end male threads (mm) a b c e f g h Bore size (mm) 20 12.5 15 M10 x 1.25 6 10 23 66 25 15.5 18 M12 x 1.25 6 12 26 71 32 22 25 M16 x 1.5 7 14 35 91 40 27 30 M20 x 1.5 7 19 40 105 50 32 35 M24 x 1.5 8 24 46 116 63 42 45 M30 x 1.5 9 30 58 135 80 57 60 M39 x 1.5 14 41 77 165 100 72 75 M48 x 1.5 21 50 101 207 285 CHKG Series Dimensions Foot type/CHKGL 2 x Rc P Width across flats f c R R Lg

200 100 101 26 25 200 Stroke (mm) Stroke (mm) MGPW MGPW MGPWL32 to 63, MGPWA32 to 63 MGQ (23) L = 50 mm, V = 200 mm/s or less (24) L = 100 mm, V = 200 mm/s or less MGG 100 100 MGC MGF MGZ 50, 63 MGT 50, 63 50, 63 50, 63 50, 63 Load mass m (kg) Load mass m (kg) 32, 40 50, 63 32, 40 32, 40 32, 40 32, 40 10 10 32, 40 D1 1 10 50 51 100 101 200 10 100 51 50 101 200 -X Stroke (mm) Stroke (mm)

Y1 Plate 25 31 X 41 Z A A port B port B port A port 29 F 0 0.036 9h9 A parallel key is used instead of single flat for size 40.

A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits

A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits

D-B5, B6 20 to 100 D-G5, K5, G5W D-K59W 20 to 100 Hs Hs 24.5 24.5 B A B A Auto Switch Proper Mounting Position (Detection at Stroke End) (mm) Auto Switch Mounting Height (mm) Auto switch model D-M9 D-M9W D-G5/K59 D-G5W/K59W D-B5 D-B64 D-A9 Auto switch model D-G5/K5 D-G5W D-K59W D-B5/B6 D-M9 D-M9W D-A9 Bore size Bore size A 41 40.5 42 39 46 44.5 A 31.5 31 32.5 29.5 36.5 35 48 47 A 37 36.5

PV SV 41. Select temperature alarm monitoring method from the table below with [] key or [] key, and confirm by pressing SEL. Table 5.16-20 List of set value Initial value Set value Item Explanation (Default setting) Alarm monitoring starts at the same time as it is turned on.

PV SV 41. Select temperature alarm monitoring method from the table below with [] key or [] key, and confirm by pressing SEL. Table 5.16-20 List of set value Set value Item Explanation Initial value (Default setting) Continuous monitoring Alarm monitoring starts at the same time as operation starts.

PV SV 41. Select temperature alarm monitoring method from the table below with [] key or [] key, and confirm by pressing SEL. Table 5.16-20 List of set value Set value Item Explanation Initial value (Default setting) Continuous monitoring Alarm monitoring starts at the same time as operation starts.

PV SV 41. Select temperature alarm monitoring method from the table below with [] key or [] key, and confirm by pressing SEL. Table 5.16-20 List of set value Set value Item Explanation Initial value (Default setting) Continuous monitoring Alarm monitoring starts at the same time as operation starts.

Analog Output ISE35 Voltage output Current output A B C Range For vacuum pressure Rated pressure range PSE 0 0.0 to 101.0 kPa 101 kPa 5 20 Analog output [mA] Analog output [V] IS For compound pressure 100.0 to 100.0 kPa 100 kPa 100 kPa For positive pressure ISG 0.100 to 1.000 MPa 0.1 MPa 0 1 MPa ZSM1 1 0.6 4 2.4 B A C B A C Pressure Pressure Functions (Refer to pages 41 and 42 for details

Applicable pressure sensor PSE531 PSE541 PSE561 PSE530 PSE560 PSE564 PSE550 PSE532 101 to 101 10 to 101 10 to 100 0.1 to 1 50 to 500 0.2 to 2.00 Set (differential) pressure range 5%R.D.

Head Flange (mm) Bore size (mm) Standard stroke A AL D J B B1 C H1 H ZZ E F FX FD FT GA GB I KA MM NA P S 20 25 32 40 50 63 80 100 12 12.5 11 10.5 15 15 17 20 85 92 94 101 130 130 162 166 14.5 17.5 17.5 23.5 29 29 35.5 35.5 5 6 6 8 11 11 13 16 14 16.5 20 26 32 38 50 60 20 23 23 29 35 35 44 44 Up to 200 12 15 15 20.5 26 26 32.5 32.5 40 44 53 61 76 92 104 128 13 17 17 19 27 27 32 41 8 10 12

ZPT13 U C ZPT16 U C U C U C 10 12 1.7 ZPT40 6.5 15 4.5 40.5 40 43 18.5 24.5 50.5 3.3 17 38 43 3 12 3.8 25 3 41.5 25 13 15 20 1.8 ZPT50 7.5 50 53 19.5 25.5 51.5 16 18 12.5 17.5 38.5 43.5 3.5 1.2 Deep Deep H: M6 x 1 H: M8 x 1 Y B C F G C F G D E Model A H: M5 x 0.8 H: M6 x 1 Y Model A B E F E F C D ZPT40D 40 43 29 35.5 3 25 61 4.5 15 51 17 ZPT10D 16 18 16 20 42 25 47 7 21 ZPT16D 10 12 15 20 41

) 36 (33) 66 0.5 59 (54) 52 (49) 41 (39) 79 0.1 0.2 4 0.3 40 (30) 37 (29) 31 (23) 54 2) 46 (37) 49 (44) 41 (36) 68 0.5 63 (57) 57 (51) 46 (43) 82 0.1 0.2 6 0.3 43 (34) 39 (30) 35 (28) 54 2) 49 (41) 53 (50) 47 (43) 68 0.5 67 (64) 61 (59) 54 (51) 81 1) ( ) 2) ZQ05A0.35MPaZQ07AZQ10A0.43MPaZQ000A0.4MPa 3) (PD) V PD [MPa] ZQ05A ZQ07A ZQ10A ZQ000A 0.05 11 10 8 16 0.15 22 20 17 32 3.2 0.25

26.5 Weight 57 g 29 16 24 + Stroke 26 23% volume reduction 25.5 + Stroke 29 Weight 61 g 42% weight reduction 32 Weight 106 g 36 20 40% volume reduction 30 27.5 + Stroke 34 + Stroke 36 Weight 82 g 45% weight reduction 36 Weight 150 g 40 25 40% volume reduction 30 + Stroke 33.5 37.5 + Stroke 40 Weight 135 g 33% weight reduction 43.5 1 32 Weight 202 g 49.5 35% volume reduction 32.5 + Stroke 41

Data Symbol Specifications Anti-corrosive specifications for guide unit (N) -X42 Operating pressure (MPa) Bore size (mm) Rod size (mm) Operating direction Piston area (mm2) 0.7 0.6 0.5 0.4 0.3 0.2 71 61 51 40 30 20 101 R 4 8 53 45 38 30 23 15 75 L 158 136 113 90 68 45 226 R 6 12 119 102 85 68 51 34 170 L 281 241 201 161 121 80 402 R 8 16 211 181 151 121 91 60 302 L 440 377 314 251 188 126