U, D)-SSL1 Y VQ2000/4000/5000 EX123 (U, D)-SSL2 Y IP53 or NEMA12 comes as optional.
D + + MADE IN JAPAN MADE IN JAPAN SMC SMC Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22
) 2 2 3 3 4 READY 4 5 ALARM 5 6 6 7 7 0 0 8 8 9 9 A A () B B C C D D 1 E E 2 F F 0 1 F0 1 71 () F8 2 F0 2 F0 (1 )*2 (2 ) *1 3 F0 3 F0 ()*2 *1 RWw0,bit4F: 12 *2 RWw0,bit4F: 93 - (2)[IO] PLC PLC Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP
Body Size: 30 (Applicable AC Size: AC30), Handle Operation: Single Action, Thread Type: Rc, Port Size: 02 (1/4), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: 30 (Applicable AC Size: AC30), Handle Operation: Single Action, Thread Type: F (G), Port Size: 03 (3/8), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: 30 (Applicable AC Size: AC30), Handle Operation: Single Action, Thread Type: F (G), Port Size: 02 (1/4), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: Applicable AC Size: AC30, Handle Operation: Single Action, Thread Type: Rc, Port Size: 1/4, Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: Applicable AC Size: AC30, Handle Operation: Single Action, Thread Type: G, Port Size: 3/8, Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: Applicable AC Size: AC30, Handle Operation: Single Action, Thread Type: G, Port Size: 1/4, Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
*1) Procedures for resuming operation when alarm group D is generated 1.
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
Bore size (mm) Auto switch model 32 40 50 63 80 100 D-A9/A9V D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL BMB5-032 BMB5-032 BA7-040 BA7-040 BA7-063 BA7-063 D-A3/A44 D-G39/K39 BMB2-032 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 CLJ2 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F D-F5BAL D-F5NTL CLM2 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 CLG1 CL1 The above figure shows the mounting example of D-A9(V)/M9(V)/M9W
0040 0001 BB [CR][LF] :01 03 02 09E1 10 [CR][LF] Answer 25.29 deg.C. 0041 Reading external Sensor temperature 1 :01 03 0041 0001 BA [CR][LF] :01 03 02 09E1 10 [CR][LF] Answer 25.29 deg.C. 0043 Reading status 1 :01 03 0043 0001 B8 [CR][LF] :01 03 02 0005 F5 [CR][LF] Run with alarm 0044 Alarm flag 1 1 :01 03 0044 0001 B7 [CR][LF] :01 03 02 8000 7A [CR][LF] ERR15 :01 06 0050 0 A9 [CR][LF] :
A A B C D E F A B C D A B C D A B C D A B C D Tubing O.D. PA 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 2 3 4 1/8" 1/8" PAX 1/8" 1/8" PB 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" Note) For each body class, the second and later numbers or symbols indicate reducing.
Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3
D-M9N D-M9B D-M9P Auto switch part no.
CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B
Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
B K P C C C U K P O A A S H L to C U S O H L to B D !
Common exhaust: VV3P5-41Stations 1-03 (G) (E) (T) (D, Y) (X port) (M5 x 0.8) N.C.