SMC Corporation of America
Elite Part Number Search
Search Results "SY100-30-3A-50"

Caution Without light SY100-61-1 SY100-61-1-C With light Rated voltage Voltage symbol Part number Part number (For AV) (For AVL) DC24V 24V SY100-61-3-05 SY100-61-3-05-C DC12V 12V SY100-61-3-06 SY100-61-3-06-C AC100V 100V SY100-61-2-01 SY100-61-2-01-C AC200V 200V SY100-61-2-02 SY100-61-2-02-C AC110V 110V SY100-61-2-03 SY100-61-2-03-C AC220V 220V SY100-61-2-04 SY100-61-2-04-C

G Lead wire length 0.6m Grommet Coil voltage H Lead wire length 1.5m 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 1 2 3 4 5 6 220VAC (50/60Hz) 24VDC 12VDC 30 Base Mounted Type Series VQ5000 Manifold Specifications Piping specifications Port size Note) Max. applicable stations Series Base model Type of connection Applicable solenoid valve 5 station weight kg (lb) Ports A, B location

50 200 3 3 Communication CN4 cable PC (The PC should be obtained separately.)

30 31 30 33 42 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 34 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 41 34 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 39 34 4D HECR 5-6 MODBUS communication function 5.6 Function codes The table berow function codes to read or write register.

Bonnet assembly/construction part number:1 Valve size 25 40 50 XLDV25-30-1 XLDV40-30-1 XLDV50-30-1 Valve size 63 80 100 160 XLDV63-30-1 XLDV80-30-1 XLDV100-30-1 XLDV160-30-1 Note1) The magnet for auto switch is not provided. When the magnet for auto switch is necessary, add -M9// at the suffix of the part number.

Allowable load Size Allowable radial load(N) Allowable thrust load(N) Allowable moment (Nm) 1 20 15 0.3 3 40 30 0.7 7 50 60 0.9 20 60 80 2.9 Table rotation range Angle adjustment is possible as shown in the Fig. 2 below using adjustment bolts (A) and (B).

Model Position /No. of solenoid TYPe Port size (NPTR Cv factor Max.Ooerelino Response time (ms) Weight lbs (kst Plug-in Non Plug-in cycle CPM 2 position Single NVFF3l00 NVFR3110 Y1 300 30 or less 0.68 (0.31) 2.3 Double NVFB3200 NVFR3210 11 300 30 or less 0.90 (0.41) 2.3 Closed center NVFR3300 NVFRgtl0 k 1 . 9 180 50 or less 0.95 (0.43) 2.0 Exhaust center NVFF3400 NVFR3410 k 1 . 9 '180 50

Model Position /No. of solenoid TYPe Port size (NPTR Cv factor Max.Ooerelino Response time (ms) Weight lbs (kst Plug-in Non Plug-in cycle CPM 2 position Single NVFF3l00 NVFR3110 Y1 300 30 or less 0.68 (0.31) 2.3 Double NVFB3200 NVFR3210 11 300 30 or less 0.90 (0.41) 2.3 Closed center NVFR3300 NVFRgtl0 k 1 . 9 180 50 or less 0.95 (0.43) 2.0 Exhaust center NVFF3400 NVFR3410 k 1 . 9 '180 50

Note C6: With 6 One-touch fitting Supply/Exhaust block assembly C6 C8 SZ3000-50-2A1 C8: With 8 One-touch fitting For D side End block assembly SZ3000-53-3A SZ3000-53-4A SZ3000-114-3A SZ3000-114-1A VZ1000-11-12 For U side End block assembly 3 Bushing assembly 4 Bushing assembly 5 DIN rail Refer to page 7. 6 Manifold station expansion Station expansion is possible at any position. 1.

Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04 Without light SY100-82-1 Caution With light Rated voltage Voltage symbol Part number 24 VDC 24 VN SY100-82-3-05 12 VDC 12 VN SY100-82-3-06 100

Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04 Without light SY100-82-1 Caution With light Rated voltage Voltage symbol Part number 24 VDC 24 VN SY100-82-3-05 12 VDC 12 VN SY100-82-3-06 100

Lead wire length Nil 6 10 15 20 25 30 50 Positive common specifications : SX100-40-4S300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For single solenoid For double solenoid For 3 position type For 4 position type : SX100-40-4DElectric circuit diagram (With positive common and light/surge voltage suppressor) Negative common specifications : SX100-41-4SFor single solenoid For

center trunnion Auto switch model 40 50 63 80 100 Center trunnion 35 55 Different surfaces Same surface 80 90 75 2 35 + 30(n 2) (n = 2, 3, 4, ) 75 + 30(n 2) (n = 2, 4, 6, 8, ) 80 + 30(n 2) (n = 2, 4, 6, 8, ) 90 + 30(n 2) (n = 2, 4, 6, 8, ) n Different surfaces D-A44 55 + 50(n 2) (n = 2, 3, 4, ) 75 + 50(n 2) (n = 2, 4, 6, 8, ) 80 + 50(n 2) (n = 2, 4, 6, 8, ) 90 + 50(n 2) (n = 2, 4, 6, 8,

side 35 + 30(n2) n = 2, 3, 4 75 + 30 (n 2) n = 2, 4, 6, 8 80 + 30(n2) n = 2, 4, 6, 8 90 + 30(n2) n = 2, 4, 6, 8 90 + 50(n 2) n = 2, 4, 6, 8 55 + 50(n 2) n = 2, 3, 4 75 + 50(n 2) n = 2, 4, 6, 8 80 + 50(n 2) n = 2, 4, 6, 8 Different sides With n D-A44 Same side 10 20 100 75 80 90 75 80 90 100 100 100 1 Different sides With 2 Same side D-A3C D-G39C D-K39C 20 + 35(n 2) n = 2, 3, 4 75 +

30 31 35.5 43 43 D-C73C, D-C80C D-B5, D-B6 D-B59W Bore size (mm) B 28.5 28.5 29.5 32.5 40.5 40.5 Hs 24.5 27 30.5 35 40.5 47.5 A 30 30 31 35.5 43 43 B 28.5 28.5 29.5 32.5 40.5 40.5 B 22.5 22.5 23.5 26.5 34.5 34.5 B 25.5 25.5 26.5 29.5 37.5 37.5 Hs 27 29.5 33 37.5 43 50 A Hs 27 30 33.5 38 43.5 50.5 A 27 27 28 32.5 40 40 Hs 27.5 30 33.5 38 43.5 50.5 CS1 20 25 32 40 50 63 24 24 25 29.5 37 37

Lead wire length Nil 6 10 15 20 25 30 50 Positive common specifications : SX100-40-4S300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For single solenoid For double solenoid For 3 position type For 4 position type : SX100-40-4DElectric circuit diagram (With positive common and light/surge voltage suppressor) Negative common specifications : SX100-41-4SFor single solenoid For

(High pump head Rated current of leak voltage x size [Optional]) current (A) [mA] HRR012-A/W-101-phase AC100V (50/60Hz) 15 30 1-phase HRR018-A/W-10AC115V (60Hz) HRR012-A/W-2010 30 HRR018-A/W-203 cores x 14AWG HRR024-A/W-20(3 cores x HRR030-A/W-20HRR012-A/W-20-T 2.0mm2) 1-phase HRR018-A/W-20-T HRR024-A/W-20-T HRR030-A/W-20-T (including 200-230V AC ground) (50/60Hz) 15 30 HRR012-A/W-20-T1 HRR018

4) 2 n = 4, 8, 12, 16 100 + 50 (n 4) 2 n = 4, 8, 12, 16 110 + 50 (n 4) 2 Different sides D-B59W n 75 + 50 (n 2) n = 2, 3, 4 90 + 50 (n 2) n = 2, 4, 6, 8 100 + 50 (n 2) n = 2, 4, 6, 8 110 + 50 (n 2) n = 2, 4, 6, 8 Same side 15 90 100 110 35 100 100 110 100 1 Different sides 2 Same side 100 100 110 D-A3 D-G39 D-K39 35 + 30 (n 2) n = 2, 3, 4 100 + 30 (n 2) n = 2, 4, 6, 8 100 + 30 (n

E E H L L M Min. port size W M H LQ3U1A 1/8" 10 9 11 46.5 44.5 14 2 10 LQ3U2A 1/4" 17 16 16 57 55 20 4 14 LQ3U3A 3/8" 22.5 19.5 21 79 73 25 6.4 18 LQ3U4A 1/2" 24.5 22.5 24 88 84 29 9.5 22 LQ3U5A 3/4" 26.5 24 32 103 98 37 16 30 LQ3U6A 1" 30 26 41 122 113.5 49 22 36 LQ3U7A 1 1/4" 35 35 50 142 142 64 28.5 46 LQ3U8A 1 1/2" 39 60 152 77 36 55 Class 7, 8 924 A Union Reducing LQ3 Series How to

Please consult with SMC regarding other voltages. 30 Manifold Options Blanking plate assembly P Series 10, 20 VVCW20 3A P Series 30 VVDW 0 3A 2 Series Material 1 2 Material 10 20 Plate material Seal material NBR FKM EPDM Symbol G H J Plate material Seal material NBR FKM EPDM Symbol G H J Stainless steel Stainless steel Plate material is stainless steel only. 248 Series VDW10/20/30 Compact