-15 -20 A M3 x 27l M3 x 29l M3 x 31l M3 x 33l M3 x 38l M3 x 27l M3 x 29l M3 x 31l M3 x 33l M3 x 38l M3 x 43l M3 x 27l M3 x 29l M3 x 31l M3 x 33l M3 x 38l M3 x 43l 5 18 5 M3 x 18l 5 18 5 M3 x 18l 5 18 5 M3 x 18l 7-2-6 6 Mini-free Mount Cylinder Series CUJ Clean Series How to Order Double acting 10 6 8 D C D UJB F8N Number of auto switches Nil 2 pcs. 1 pc.
Tightening of M3, M5, and M6 screws 1) M3 After tightening by hand, tighten an additional 1/4 rotation with a tool. 2) M5 and M6 After tightening by hand, tighten an additional 1/6 rotation with a tool. Over tightening can cause damage to the threads and/or air leakage due to deformation of the gasket. Under tightening can cause loose threads and air leakage, etc. 1.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mounting screw (M4) Terminal block cover M3 screw Gasket 6 mm Electrical entry 2-G3/4 Step 3.
Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" l/min (ANR) {Nl/min} 38 7 Flow rate 12 Controlled flow Effective area mm 0.6 0.2 0.1 l/min (ANR) {Nl/min} 230 Flow rate
Corrected air flow capacity = Air flow rate (Correction factor A x B x C x D) 4 Corrected air flow capacity = 0.3 m3/min (0.82 x 0.96 x 1 x 0.88) = 0.43 m3/min Corrected air flow capacity = 0.4 m3/min (0.95 x 0.93 x 1 x 0.88) = 0.51 m3/min 5 Select the model.
How to Order Needle Valve/Flow Rate Characteristics 0 2 F A 1 AS 1 M3 X790 06 AS1201F-M350 45 40 35 30 25 20 15 10 5 0 0.5 0 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 Inlet pressure: 0.5 MPa Port size Push-lock type Body size Flow rate [L/min (ANR)] 1 M3 x 0.5 M3 M3 x 0.5 Applicable tubing O.D.
Nil P NPN specification PNP specification Cable full length 1 m 2 m Symbol 01 02 Individual Special Order (Please contact an SMC sales representative.) Note 1) 11 m or longer power supply cables are not CE Marking-compliant. Note 2) Use standard power supply cables for 3 m and 10 m lengths.
(Tightening torque of M3 screw should be 0.5 to 0.7Nm.) tModification of the detecting position should be made in the condition of e.
(Example) For M3: L1 = 6 mm Applicable shaft types: S, W, Y Q1 = M L1 + (3 x P) L1 = (mm) Q1 M3 M4, M5, M6 M4, M5, M6 M4, M5, M6, M8 M5, M6, M8, M10 Size 30 50 63 80 100 100 Symbol: A2 Machine female threads into the short shaft.
(Example) For M3: L1 = 6 mm Applicable shaft types: X, Z The maximum dimension L2 is, as a rule, twice the thread size.
(mm) Applicable fitting size Model KJY02-M3 KJY02-M5 2 M3 x 0.5 M5 x 0.8 KJR02-04 4 2 KJU02-00 2 KJU02-23 KJU02-04 2 Bulkhead union KJE Plug KJP Applicable tubing O.D. (mm) Model Applicable fitting size Model KJE02-00 2 KJP-02 2 2 Polyurethane tubing Series TU 2 Miniature fittings Series M
How to order SFD 1 1 0 C08 Option Symbol Option Nil None B Bracket Port size Symbol C04 4 C06 6 C08 8 02 N02 F02 Connection size Clean One-touch fittings (KP series) Rc1/4 NPT1/4 G1/4 7 Document No.DOC1018377 4. Construction and Replacement parts SFD110-C** SFD110-*02* Component Parts No.
Example) G36-P4-01-X30 Regulator 2 Port Solenoid Valve AR 20 E 02 1 VCA27A S 5 DL 02 4 Q Port size Thread type Voltage CE marked 02 02N 02F Rc 1/4 NPT 1/4 G 1/4 Rc NPT G Nil N F 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Throttle Option (The shape of pressure gauge) Note 2) Nil S B K Without throttle and manual lock With throttle With manual lock With manual lock
mark shows the dimensions of the solenoid valve VF3120K-1G1-02-X14. Drawing shows the auto switch mounted on the port side.
Tightening torque for round head Phillips screws for tie-rods of the regulator manifold. 0.32 0.03N.m M3 thread Square nut (M3) Square nut (M3) Note) M3 threads and square nuts are not included. End block 0.32 0.03 N.m Round head Phillips screw (with SW) (M3) 3. Tightening torque for hexagon socket set screws for DIN rail of the regulator manifold DIN rail 2.
MLU ML1C DMounting of Auto Switch -X Except D-P5DWL D-P5DWL 20Data Auto switch mounting screw Hexagon socket head cap bolt With SW M3 x 0.5 x 5l M3 x 0.5 x 6l Auto switch Switch mounting bracket With SW, M3 x 0.5 x 14l Round head Phillips screw 8 x 3.3 x t0.8 Flat washer Auto switch Auto switch mounting nut Auto switch mounting nut Tightening torque of auto switch mounting screws should
Width across flats 3.5 23 9 4.5 4.5 6.5 3.5 2-M3 x 0.5 (Port size) 2-M3 x 0.5 (Port size for axial piping type MTS8-P) 9 2-M3 x 0.5, effective length 5 0.2 5 +0.035 +0.025 4 16 0.2 22 12 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 41 + Stroke M2.5 x 0.45 12 53
T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 M Model 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Controller Connectors
x 0.5 (port size) 2-M3 x 0.5 (port size for axial piping type MTS8-P) 9 2-M3 x 0.5 Effective length 5 0.2 5 +0.035 +0.025 4 16 0.2 22 12 M2.5 x 0.45 12 41 + Stroke 53 + Stroke 9 15 0.2 9 4-M3 x 0.5, effective length 5 10 15 0.2 Rod end male threads Width across flats 3.5 +0.035 +0.025 4 M3 x 0.5 3.9 M3 x 0.5 6.4 7 8 4 24 5.5 2.4 Stud bolt part number: MT-S8 Rod end nut part number: NTJ-006A