Dimensions: Without Buffer ZP2-R W-A5 04 06 ZP2-R 20 W-A5 04 06 ZP2-R 30 W-A5 04 06 Width across flat 8 (Hexagon) Width across flat 8 (Hexagon) Width across flat 8 (Hexagon) Width across flat 10 (Hexagon) Q Q Q Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) 4 4 4 4 4 4 21 21 21 M5 x 0.8 M5 x 0.8 M5 x 0.8 P P P (60) (60) (60) S S 31 8 31 S 31 14.9 A 14.9 14.9 R R R 6 6 6 M5
Q = m x C x (Tt T0) t Q = m x C x (Tt T0) t x 860 = x V x C x T t = x V x 60 x C x T t x 860 = 1 x 60 x 4.2 x 12 900 = 3.36 [kJ/s] 3.4 [kW] = 1 x 60 x 60 x 1.0 x 12 15 x 860 Cooling capacity = Considering a safety factor of 20%, 3.4 [kW] x 1.2 = 4.08 [kW] = 3.4 [kW] 2880 [kcal/h] 860 Thermo-cooler Q x t: Heat volume [kJ] Cooling capacity = Considering a safety factor of 20%, 3.4 [kW
8 40 60 10 (Connection: 1/4) 30 45 10 (Connection: 3/8, 1/2) 35 50 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 15 kg/h is P1 0.55 MPa for a 2 orifice and P1 0.28 MPa for a 3 orifice.
Pressure gauge unit 2) w q w q w q Unit psig/bar MPa Code No code MPA Sample Order Number Port AP1001S e q FV4 FV4 FV4 FV4 w FV4 FV4 FV4 FV4 r 2PW 3PW 2PW 3PW 3PW 4PW 2) Pressure gauge unit MPa or psig/bar selectable.
Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Body Option Pilot type 0 1 Standard Direct manual override R Internal pilot External pilot Nil Option How to Order Pilot Valve Assembly Option SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC
Q = qm x C x (T2 T1) r x qv x C x iT 60 = 1 x 10 x 4.2 x 103 x 2.0 60 = Q = qm x C x (T2 T1) 860 = 1400 [J/s] 1400 [W] g x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 1400 [W] x 1.2 = 1680 [W] 1 x 10 x 60 x 1.0 x 103 x 2.0 860 = qv: Circulating fluid flow rate Q: Heat generation amount Users equipment T2: Return temperature 120 [cal/h] 860 = 1400 [W]
VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option 3-5-94 95 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR6000 Cylinder Speed Chart Use as a guide for selection.
Q[l/min(ANR)] = X X 60 X C X D2 X W 4 X 106 (P2 + 0.101) 0.101 Q[l/min(ANR)] = X X 60 X 1 = 841 X 1002 X 200 4 X 106 (0.8 + 0.101) 0.101 Refer to p.1.13-2 for flow rate characteristics table. Select booster regulator size from flow characteristic stable.
0 i q JSXD 3 1 C N R 5 G D B 02 q Size w Valve type e Body material Symbol Size 3 30 4 40 5 50 6 60 7 70 8 80 9 90 Symbol Valve type Symbol Body material Size 30 40, 50, 60 70, 80, 90 C Brass V V S Stainless steel V V B Bronze V A Aluminum V 2(OUT) 1 N.C. 1(IN) r Seal material t Port size i Electrical entry Symbol Seal material N NBR F FKM E*1 EPDM Symbol Connection Port size Size
16 B CJ2 A M9BW B Z 60 16 B CDJ2 A With auto switch q w e r t y u i o !
Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz Refer to Table (3) shown below for availability.
q END w END q END w END q Switch for end of rotation q Switch for end of rotation w Switch for end of rotation q Switch for end of rotation w Solid-lined curves indicate the rotation range of the output key (keyway).
6 Q: 8 Model A B C D F H I J K P Q: 6 Q: 8 Y K P K P ZPT20F10-0-A14 ZPT40F10-0-A14 18.5 39 51.5 118 136.5 13 140 5 12.5 20 22 40 43 13 15.5 36 48.5 50 115 13 133.5 13 137 12.5 52.5 50 ZPT25F10-0-A14 ZPT50F10-0-A14 19.5 40 119 137.5 141 6 13.5 25 28 50 53 ZPT32F10-0-A14 16 36.5 49 115.5 134 135.5 13 32 35 Additional Dimensions by Stroke (mm) Additional Dimensions by Stroke (mm) K P Q: 6 Q
Q = qm x C x (T2 T1) x qv x C x iT 60 1 x 35 x 4.186 x 103 x 3.0 60 = = qm x C x (T2 T1) 860 Q = = 7325 [J/s] 7325 [W] = 7.3 [kW] x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 7.3 [kW] x 1.2 = 8.8 [kW] 1 x 35 x 60 x 1.0 x 103 x 3.0 860 = Thermo-chiller qv: Circulating fluid flow rate Q: Heat generation amount T2: Return temperature Users equipment 7325
VAC, 50/60 Hz XLA 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz U XL XL 5 24 VDC 6 12 VDC S type: Not available for AC.