SMC Corporation of America
Elite Part Number Search
Search Results "SGH233B-30G15Y-5V-B1"

Size: 2 (200), Valve Type: 0 (3-port), Seal Material: B (FKM), Pressure Range: 30 (0 to 3MPa), Thread: G (ISO1179-1), Port Size: 15 (1/2, SGH200), Voltage: 5 (24VDC), Electrical Entry: W (M12 Connector, 4-Pin Type), Light/Surge Suppressor: Z (Light/Surge Suppressor, Non-polar)

Size: 2 (200), Valve Type: 0 (3-port), Seal Material: A (NBR), Pressure Range: 30 (0 to 3MPa), Thread: G (ISO1179-1), Port Size: 15 (1/2, SGH200), Voltage: 6 (12VDC), Electrical Entry: D (DIN Terminal)

Size: 200, Valve Type: 3-port, Seal Material: NBR, Pressure Range: 0 to 3MPa, Thread: ISO1179-1, Port Size: 1/2, SGH200, Voltage: 24VDC, Electrical Entry: DIN Terminal, Light/Surge Suppressor: -, Manual Override: -, Bracket: -

Size: 200, Valve Type: 3-port, Seal Material: FKM, Pressure Range: 0 to 3MPa, Thread: ISO1179-1, Port Size: 1/2, SGH200, Voltage: 24VDC, Electrical Entry: M12 Connector, 4-Pin Type, Light/Surge Suppressor: Light/Surge Suppressor, Non-polar, Manual Override: -, Bracket: -

Size: 200, Valve Type: 3-port, Seal Material: NBR, Pressure Range: 0 to 3MPa, Thread: ISO1179-1, Port Size: 1/2, SGH200, Voltage: 12VDC, Electrical Entry: DIN Terminal, Light/Surge Suppressor: -, Manual Override: -, Bracket: -

Model: SGC200, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1.6 MPa, Thread: NPT, Port Size: 3/8, Pilot Valve: 0.35 W Type, V116, Voltage: 24 VDC, Electrical Entry: M-12 Connector, 5-pin Type, Surge Suppressor: None, Manual Override: Non-locking Push Type, Bracket Mounting Position: Without Bracket, Auto Switch: M [Without Autoswitch (With Built-in Magnet)], Lead

Model: SGC200, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1.6 MPa, Thread: NPT, Port Size: 1/2, Pilot Valve: 0.35 W Type, V116, Voltage: 24 VDC, Electrical Entry: M-12 Connector, 5-pin Type, Surge Suppressor: None, Manual Override: Non-locking Push Type, Bracket Mounting Position: Bracket on the Right Side, Auto Switch: -, Lead Wire: -, Number: -

Model: 2 (SGC200), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 16 (0 to 1.6 MPa), Thread: N (NPT), Port Size: 10 (3/8), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: V (M-12 Connector, 5-pin Type), Surge Suppressor: None, Manual Override: Non-locking Push Type, Bracket Mounting Position: Without Bracket, Auto Switch: M [Without Autoswitch

Model: 2 (SGC200), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 16 (0 to 1.6 MPa), Thread: N (NPT), Port Size: 15 (1/2), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: V (M-12 Connector, 5-pin Type), Surge Suppressor: None, Manual Override: Non-locking Push Type, Bracket Mounting Position: B2 (Bracket on the Right Side)

Part Number Description: SEAL GASKET   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 139   Family Description: FLOW CONTROL W/FITTING   Class Code: B1   Part Code: 2   Reference Code:  J   Click here to report information errorImage shown may not match exact part number

Brackets Accessary i Symbol Contents B1 EXW1-NT1 For the following EX600-W models EX600-WEN1/2 EX600-WPN1/2 EX600-WSV1/2 EXW1-AB1 B2 EXW1-NT1 For the EXW1 series EXW1-AB2 As the brackets and the NFC Reader/Writer worsen the performance of wireless communication in the 2.4 GHz band, use them only during configuration and remove them during normal operation.

1650518510 Advanced Configuration 3 HART PCB Serial Number 1647317020 4 Device Serial Number PH17100205 5 HART Board HW revision H033592-1.20 6 Software rev 193 7 HART Board Dac SW revision UNKNOWN Configuration Position Control 1 Position Control Performance Level Aggressive (A);Fast (b); Optimum (C);Stable (d); Maximum Stability (E); Capacity Booster, Aggressive (A1); Capacity Booster, Fast (b1

CR ,, (EE ) 2ROM E 2ROM (100 ,E ), 2ROM E (3) : # : ASCII ,, 30H ) # 0 0 V R 23H 30H 30H 56H 52H 23H+30H+30H+56H+52H=12BH 2B ,30H 32H 3BH : # 0 0 V R 2 ; [CR] 23H 30H 30H 56H 52H 32H 3BH 0DH )ASCII ASCII 09 A B C D E F ASCII 30H39H 41H 42H 43H 44H 45H 46H 30H39H 3AH 3BH 3CH 3DH 3EH 3FH 27 - (4) 1bit () bit (ON 1) b7 b6 b5 b4 b3 b2 b1 1 0 () ON () (5) VR # 0 0 V R [CR] No. #

Select cable type and len gth surely. e xamp le S2S2Standard c able 2m+ d river LEC SS2 S2 Standard c able2m Nil Witho ut cab le and driver 100 to 120 LECSB1S B1 200 to 230 LECSB2S B2 100 to 120 LECSC1-S C1 *5 Mo tor cable and enc o der cable are included as a ccessories.

LECP,LECA LECPA Output pin Output pin0 B1 12 Output pin0 Output pin1 B2 13 keykey Output pin2 B3 14 Output pin1 Output pin3 B4 15 Output pin4 B5 16 Output pin5 B6 17 Output pin6 B7 18 Output pin7 B8 19 Output pin8 B9 20 Last output pin Output pin9 B10 Output pin10 B11 Output pin11 B12 Output pin12 B13 (6-3-5) Input pin monitor It is possible to monitor the input pin of the controller with

solenoid valve status OFF and ON (0: OFF, 1: ON), and the output number starts at zero from LSB (least significant bit). (3) Fuse disconnection details The power supply fuse disconnection for the SI unit solenoid valves can be monitored by the link special register of the master station. 0: Normal 1: Fuse disconnected Buffer area of master station Example: QJ61BT11N b15 b14 b13 b12 b3 b2 b1

Meaning of each bit (ON: 1) b7 b6 b5 b4 b3 b2 b1 in HOLD inputting Indication overflow 1 : fixed Indication underflow Counter overflow (reset is required) 0 : fixed Output of cylinder stop (Count Mode) (5) Communication format details Reading counts VR Command Block # 0 0 V R [CR] Unit No. Command Check sum code Response Block # 0 0 V R [CR] Unit No.

Power supply cable AC adapter AC cord Bracket IZF10-B1 Note) 4 retaining bolts are included. 7 - Doc. no. IZ*-OMT0002 1-3. Maintenance parts Cartridge case IZF10R-A1 1-4. Option Cleaning kit IZS30M2 IZS30-A0201 IZS30-A0202 Adjustment screwdriver (10 replacement felt pads) (1 replacement rubber grindstone) (With 1 felt pad, 1 rubber grindstone, and 2 replacement felt pads) IZS30M1 2.

The pressure is set (output) or is monitored (input) by the data of [b15,b1,b0]. Subordinate position 12bit [b11b0] corresponds to 100%FS of pressure. The pressure setting is assumed that data 1332h of 120%FS is a limit value. The accuracy guarantee is to 100%FS. It might response to PLC a very high numerical value such as Fh in around outlet pressure 0.

CRJB1 CRJU1 0 Angle is adjustable: 5 at each rotation end Variations Series Rotation angle Auto switch Port location 90 100 190 180 CRJB05 CRJB 1 CRJU05 CRJU 1 Basic type D-F8 Front port D-F9 Side port With external stopper Features 2 Series CRJ Model Selection Procedure Calculation Example Operating conditions 1 List all possible operating conditions according to the mounting position. b1