collector Max 30 VDC, 50 mA NPN open collector Max 30 VDC, 50 mA 3 PNP open collector Max 30 VDC, 50 mA PNP open collector Max 30 VDC, 50 mA 3 Output transistor mode Power supply voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less
collector Max 30 VDC, 50 mA NPN open collector Max 30 VDC, 50 mA 3 PNP open collector Max 30 VDC, 50 mA PNP open collector Max 30 VDC, 50 mA 3 Output transistor mode Power supply voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less
Use 24 VDC or 12 VDC for the power source of COM. Connect DC when PNP is applied, and DC+ when NPN is applied.
(Red Green Red) 3-wire 2-wire Wiring type NPN PNP Output type IC circuit, Relay IC, PLC 24 VDC relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 VDC) Power supply voltage 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage 28 VDC or less 40 mA or less 2.5 to 40 mA Load current 4 V or less Internal voltage drop 0.8 V or less at 10 mA load current (2 V or less at 40
SYJ312-5LOZ-M3 SY100-68-A-20 Ex2 Lead wire length of 300mm (standard) SYJ312-5LPZ-M3 Symbol for connector assembly with cover Ex. 1) Cable length: 300 mm In this case, the part number for the connector assembly with cover is not required.
to +24 VDC (Voltage: Between 19 VDC and power supply voltage, Current consumption: 5 mA or less) Input signal Static electricity removal completion signal Maintenance detection signal Error signal Sensor monitor output Note 3) Max. load current: 100 mA Residual voltage: 1 V or less (Load current at 100 mA) Max. applied voltage: 28 VDC Max. load current: 100 mA Residual voltage: 1 V or less
(Example) For M3: L1 = 6 Applicable shaft types: S, Y L2 + (3 x P) L1 + ( 3 x P) Q1 = M Y axis S axis (mm) (mm) Q1 Q2 L1 = Shaft type Shaft type S Y S Y Size Size L2 + (3 x P) L2 = 50 50 M3, M4, M5, M6 M3, M4, M5 M3, M4, M5 L2= 63 63 M4, M5, M6 M4, M5, M6 M4, M5, M6 Q2 = M 80 80 M4, M5, M6, M8 M4, M5, M6 Q2 = M M4, M5, M6 100 100 M5, M6, M8, M10 M5, M6, M8 M5, M6, M8 Symbol: A33 Machine
24 VDC (Option) 100 VAC 200 VAC 110 VAC 220 VAC 1 (P) 3 (R) L-type plug connector (L) N.C.
Round head screw (M3 x 8) 4 pcs. EX600-ZMV2 (Specialized for the SY series) Enclosed parts: Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 2 pcs. -114No.EX-OMW0006-D 3.
steel/NBR POM/Stainless steel NBR NBR ASV Note) M3 type is made of stainless steel.
Part number Description Remarks ZS-28-A Power and output lead wire and connector Length: 2 m ZS-28-B Bracket Mounting screw (M3 x 5 L) 2 pcs. ZS-28-C Sensor connector 1 pc. ZS-27-C Panel mount adapter Mounting screw (M3 x 8 L) 2 pcs. ZS-27-D Panel mount adapter + Front protective cover Mounting screw (M3 x 8 L) 2 pcs.
How To Order ZSMl Port thread Electrical Specifications zsMl-T115 Power supply voltaoe10-26 VDC Operating voltage 30 VDC or less Current consumption 24 VDC; 16mA or less Internalvollage drop 100mAi 0.8V or less 15OmA; 1.5V or less -Special order Connecting with Sequencer (ZSMI -T1 1 5/ Non-Contact type 24 VDC) zsMl-T121 Operating voltage 11sVAC Current 5.-17m4 Red wire: Power source for operating
How To Order ZSMl Port thread Electrical Specifications zsMl-T115 Power supply voltaoe10-26 VDC Operating voltage 30 VDC or less Current consumption 24 VDC; 16mA or less Internalvollage drop 100mAi 0.8V or less 15OmA; 1.5V or less -Special order Connecting with Sequencer (ZSMI -T1 1 5/ Non-Contact type 24 VDC) zsMl-T121 Operating voltage 11sVAC Current 5.-17m4 Red wire: Power source for operating
Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDC For power supply status, flow rate indicator (Blinking speed changes in response to flow rate), and other error indicator Indicator light Power supply voltage Current consumption 12 to 24 VDC p10% 30 mA or less Note 3) The response time until the Enclosure IP65 set value reaches 90% in relation to the step
PLC Note 1) P4DWZ 5 m 2-wire (14) 2-color display DP79WSE 24 VDC Pre-wired connector 0.3 m Reed auto switch DC / AC magnetic field Series CKP1 P74L -X 3 m 1-color display 24 VDC 100 VAC Grommet 2-wire P74Z Individual -X 5 m Note 1) PLC: Programmable Logic Controller Note 2) There are other applicable auto switches other than the listed above.
2-color indicator 5 m 2-wire (34) Relay, PLC Pre-wired connector 0.3 m 2-wire (14) 3 m Grommet 2-wire 5 m 2-color indicator Pre-wired connector 24 VDC 2-wire (14) 0.3 m Reed auto switch DC/AC magnetic field CKP1 3 m 24 VDC 100 VAC 1-color indicator Grommet 2-wire 5 m DNote 1) Refer to page 433 when ordering the auto switch mounting bracket or switch mounting rod assembly.
Product Specifications -> 5.1Connector specifications Check that 24 VDC is supplied to the EMG Stop terminal. Supply 24 VDC to the EMG terminal. command If it is not energized, the servo will be OFF and does not operate.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Body Style: Base Mounted w/Screws, Coil Voltage: 6 VDC, Flow Rate: Power Consumption: 0.35W, Operating Press: 0.1MPa, Cv: 0.016, Electrical Entry: Grommet, Port Size: Base Mounted, w/Sub-plate, Made to Order: Universal Type, Lead Wire Length: -
Body Style: Base Mounted w/Screws, Coil Voltage: 24VDC, Flow Rate: Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011, Electrical Entry: Grommet, Port Size: Base Mounted, w/Sub-plate, Made to Order: Universal Type, Lead Wire Length: -