VEX5511-062EZ-BG Body size 5, Select, External pilot solenoid Port size 3/4 200 VAC, Grommet terminal, with light/surge voltage suppressor OptionBracket, with pressure gauge 5 3 4 200 VAC 50/60 Hz 1 1 1 110 VAC 50/60 Hz 4 7 220 VAC 50/60 Hz 24 VDC 12 VDC 11 4 11 4 5 6 11 2 9 2 2 7 240 VAC 50/60 Hz Other 9 Option Thread type Nil F N T Rc G(1) NPT NPTF Note 1) Not conforming to ISO1179-1.
[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.
AC (50/60 Hz) Bracket CE-compliant 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Nil : Without bracket F : With bracket 3 port For type W, only DC voltage is available. Note) CE-compliant: For DC only. Actuation type Bracket 1 2 Normally closed Normally open Bracket is mounted. Brackets cannot be retrofitted. External pilot type is not available.
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications
DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Bracket Nil: Without bracket F: With bracket AC (50/60 Hz) 3 port 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available. Type of actuation Bracket 1 2 Normally closed Normally open (For manifold type 20, 20R) Bracket is mounted.
IFW5 10 03 N 1 1 PSE Z I SE3 Diaphragm style flow switch PS Light 0 None Z I SE1 2 1 With neon light (110 VAC, Red) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 With neon light (110 VAC, Green) Flow range ZSP 3 With neon light (220 VAC, Red) Low flow setting
[115 VAC] 220 VAC [230 VAC] Lead wire length 0.6 m Connector type Lead wire length 3 m Connector type Note) The connector box type and serial transmission type are only available with 5 (24 VDC).
Electrical entry Rated voltage G Grommet 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz C Conduit D DIN terminal 3 110 VAC 50/60 Hz T Conduit terminal 4 220 VAC 50/60 Hz 7 240 VAC 50/60 Hz Refer to the table (1) given below for availability. 8 48 VAC 50/60 Hz 9 Other (Only AC) Table (1) Rated VoltageElectrical Entry-Electrical Option Caution Insulation type Electrical entry Electrical option 1 (100
(50/60 Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.
Specifications CD-P12 CD-P11 100 VAC Part No. 200 VAC 24 VDC Load voltage 25 mA 12.5 mA 50 mA Maximum load current Lead wire length Switch conneciton side 0.5 m Load connection side 0.5 m (Example) D-F9PWVL61 Flexible specification Auto Switch Hysteresis Internal Circuit The hysteresis is the difference between the position of the auto switch as it turns on and as it turns off.
(50/60 Hz), 200 to 230 VAC (50/60 Hz) Reference page Page 607 * Copper and zinc materials are used for the motors, cables, controllers/drivers. 545 25A-LEm Series Specific Product Precautions Be sure to read this before handling the products.
, (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC, (7) Piping length: Minimum 5 With the pressure control mode that controls the pressure automatically with the inverter.If the pressure control mode is not necessary,use the flow control function or the pump output setting function. 6 Required flow rate to maintain the cooling capacity.
) EXH (ATM) OUT x z c Symbol L bracket Metric size (light gray) 4 Nil PWR ERR Inch size (orange) C 5/32" U For manifolds SUP (VAC) EXH (ATM) OUT x z c Symbol Base type Metric size (light gray) For single unit For manifold Nil M 6 4 6 Nil Inch size (orange) 1/4" 5/32" 1/4" How to Order Manifold Assemblies (Example) U Indicate the part numbers of electro-pneumatic regulators and options to
VAC, 50/60 Hz 02 1 4 4 AC: Can be attached to Grommet, Conduit, Conduit terminal.
U C S O H L 1 Series IRV Dimensions IRV1000 IRV2000 53 55 41 30 50 SMC 35 P K U C SMC S O H L P K U C S O H L 40 34 8 x 6.5 15.4 x 5.4 Approx. 106 Approx. 50.6 18 Approx. 79 Atmosphere Atmosphere 45.5 13 SET VAC SET G SET G 30 SET VAC 43 Pad side Vacuum pump side Pad side Vacuum pump side Approx. 43 35 2-Rc 1/8 Connection port 2-Rc 1/8 Vacuum gauge port 2-Rc 1/4 Connection port Approx. 60
Rated, 24 VDC: 20.4 VDC to 26.4 VDC
Rated, 100 VAC: 85 VAC to 110 VAC
Rated, 200 VAC: 170 VAC to 220 VAC
The 100 VAC, 200 VAC, and 24 VDC voltage types have no polarity.
VS4120, VS4130, and VS3135 series valves with a grommet have 2 lead wires.
Connections: For 100 VAC, there are 2 blue wires. For 200 VAC, there are 2 red wires. And for 24 VDC, there is 1 white wire and 1 pink wire.
Wiring (Including insulating material) Power pair 1.4 mm 1.5 mm Data pair 2.05 mm 1.9 mm Connection type Spring-cage connection Rated current 4 A Power supply/3 A Communication/1 A 4 A Rating/Performance Rated voltage 48 VAC/60 VDC 125 V 48 V Contact resistance 10 m or less 30 m or less 5 m or less Insulation resistance 100 M or more 1000 M or more 100 M or more Withstand voltage 1.0
HOLD BANK1 BANK2 MULTI COUNTER:CEU5 UP Nil D 100 to 240 VAC 24 VDC Output transistor mode COUNT PRESET FUNC. LEFT RIGHT DOWN Nil P NPN open collector output SEL.