MPa Load weight: 200 kg 300 Load weight m (kg) 250 63 200 Since the conditions are horizontal extension with a speed of 500 mm/s, use graph (5).
Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
Hz) Class B NBR 200 VAC (50/60 Hz) VDW FKM Stainless steel 110 VAC (50/60 Hz) EPDM 220 VAC (50/60 Hz) VQ FKM 24 VDC Note) The armature assembly is a corrosion resistant construction. 12 VDC LVM 6 VDC 5 VDC VCA Nil Thread type 3 VDC Rc Please consult with SMC regarding other voltages.
Fig. 9-26 Pump capacity(HRL100/200/300-A/W-40 CH2) HRL Series 9.5 Pump Capacity 9-21 HRX-OM-X037 Chapter 9 Documents 9.5.5 HRL100/200/300-A/W-40-T2 CH1 0.6 60 0.5 50 0.4 Usable flow rate 40 Lifting head [m] Pressure[MPa] 0.3 30 Circulating fluid outlet 0.2 20 Circulating fluid return 0.1 10 0 0 0 5 10 15 20 25 30 35 Circulating fluid flow[L/min] Fig. 9-27 Pump capacity(HRL100/200/300-A/W-
Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.
Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.
300 0 100 200 300 100 200 300 Load (N) Load (N) Load (N) 25 25 25 Lr = 200 mm 0.08 MXQ25-150 MXQ25-150 MXQ25-150 MXQ25-10 MXQ25-10 MXQ25-20 MXQ25-20 MXQ25-30 MXQ25-30 MXQ25-40 MXQ25-40 MXQ25-100 MXQ25-125 MXQ25-150 MXQ25-50 MXQ25-75 MXQ25-10 MXQ25-20 MXQ25-30 MXQ25-40 MXQ25-50 MXQ25-50 MXQ25-75 MXQ25-75 0.12 0.10 MXQ25-75 MXQ25-75 MXQ25-75 MXQ25-40 MXQ25-40 MXQ25-40 Table displacement amount
Fingers synchronized by a rack and pinion mechanism Model/Stroke Max operating frequency (c.p.m) Opening/closing stroke (L2L1)(mm) Weight (g) Width at closing (mm) (L1) Width at opening (mm) (L2) Bore size (mm) Model Built-in dust proofing mechanism 60 20 40 60 30 60 80 40 80 100 50 100 120 70 120 160 100 160 200 56 78 96 68 110 130 82 142 162 100 182 200 150 198 242 188 246 286 76 118 156
) [Current mA] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Refer to pages 3-3-60 to 3-3-65 for manifold use.
M plug connector Rated voltage 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 2 3 4 5 6 7 9 Solenoid valve configuration Single solenoid Double solenoid Closed center Exhaust center Pressure center Manual override 1 2 3 4 5 24 VDC 12 VDC None Locking B type Locking C type Nil B C 240 VAC, 50/60 Hz Other Without auto switch B S 50 90 1 1 G CVRA1 B S 50 90 1
24 24 40 44 44 44 110 110 120 120 200 200 200 200 300 300 15 17 29 29 25 27 39 39 60 60 77 77 105 105 117 117 167 167 23 24 28 34 3 3 3 4 3.5 3.5 3.5 4.5 10 10 12 12 5 5 17 17 (mm) MGPL (Ball bushing) MGPA (High precision ball bushing) A, DB, E Dimensions (mm) MGPM (Slide bearing) A, DB, E Dimensions A E DB Bore size (mm) A E DB Bore size (mm) 50 st or less 60.5 64.5 77.5 77.5 Over 50
F G H E Stroke range 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 4 60 75 13 8 18 15.5 34 26 13 10 41 150 to 700 FX 20 25 4 60 75 17 10 22 19.5 40 32 13 10 45 150 to 700 26 20, 25, 32 32 4 60 75 17 12 22 19.5 40 32 13 11 45 150 to 1000 26 36 40 5 66 82 22 14 24 21 52 41 16 12.5 50 200 to 1000 32 S Z ZZ NN P H1 H2 I K MM N NA Bore size Stroke range 1 8 M20 X 1.5 20 146 191 200 150 to 700 M8 X 1.25
M plug connector Rated voltage Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 2 3 4 5 6 7 9 Solenoid valve configuration Single solenoid Double solenoid Closed center Exhaust center Pressure
Bore size CJ2 series Pressure 0.5 MPa Load ratio 50% Stroke 60 mm CM2 series Pressure 0.5 MPa Load ratio 50% Stroke 300 mm CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] 6 10 16 125 140 160 180 200 250 20 25 32 40 40 50 63 80 100 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
) [Current mA] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Refer to pages 3-3-60 to 3-3-65 for manifold use.
Igm: Leakage current of the servo motor (Found from Table 11.4.) 120 120 100 100 Leakage current Leakage current 80 80 60 60 40 40 [mA] [mA] 20 20 0 2 0 14 100 5.5 38 2 3.5 8 1422 38 80 150 5.5 30 60 100 3.5 8 22 60 150 30 80 Cable size[mm2] Cable size[mm2] a. 200V class b. 400V class Fig. 11.3 Leakage current example (lg1, lg2) for CV cable run in metal conduit 11 30 11.
Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.
Model C D 30 35 40 45 50 55 30 35 40 45 50 55 35 40 45 50 55 60 65 70 75 80 40 45 50 55 60 65 70 75 80 85 C' D' 35 40 45 50 55 60 35 40 45 50 55 60 40 45 50 55 60 65 70 75 80 85 45 50 55 60 65 70 75 80 85 90 Mounting bolt Mounting bolt CDQSKB12-5D -10D -15D -20D -25D -30D CDQSKB16-5D -10D -15D -20D -25D -30D CDQSKB20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQSKB25-5D -10D -15D -20D