SMC Corporation of America
Elite Part Number Search
Search Results "RZQF50-250-110"

Bracket cannot be mounted onto the 250 L/min type. Replacement part Element Part number Remarks Vinyl chloride piping tube (25 A) ZS-40-U25 25 A Vinyl chloride piping tube 1 pc.

Servo motor Graph of overload protection characteristics LE-T5 T6 Characteristics a T7 T8 T9 Characteristics b The following graphs show overload protection characteristics. 1000 1000 Operating Operating Operating 100 100 Operation time [s] Operation time [s] Servo-lock Servo-lock 10 10 1 1 0.1 0.1 100 200 300 350 0 50 150 250 350 100 200 300 400 0 50 150 250 350 (Note 1, 2) Load ratio [%

Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150

, 300 12-CY3B15 15 1000 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 12-CY3B25 25 (Both sides) Non-lube 12-CY3B32 32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63 Note 1) Stroke exceeding the standard stroke but

Standard Stroke Standard stroke (mm) Note) Bore size (mm) Symbol Specifications 25, 50, 75, 100, 125, 150 20 -XA Change of rod end shape 25, 50, 75, 100, 125, 150 25 25, 50, 75, 100, 125, 150, 200 32 25, 50, 75, 100, 125, 150, 200, 250 40 Note 1) Intermediate stroke except mentioned above is produced upon receipt of order.

Therefore, use a contact protection box with the switch for any of the above cases: The contact life may be shortened (due to permanent energizing conditions). r Where the load voltage is 110 VAC.

Station n L1 L2 L3 L1 L2 L3 Station 2 62 53 47 63 54 48 3 78 69 63 80 71 65 Station 20 350 341 335 369 360 354 4 94 85 79 97 88 82 5 110 101 95 114 105 99 6 126 117 111 131 122 116 7 142 133 127 148 139 133 8 158 149 143 165 156 150 9 174 165 159 182 173 167 10 190 181 175 199 190 184 11 206 197 191 216 207 201 12 222 213 207 233 224 218 13 238 229 223 250 241 235 14 254 245 239 267 258 252

Standard stroke (mm) 45 stroke 59 114 Mountable (Band mounting style) Auto switch Bottom mounting style Mounting 60 stroke 67 135 Weight 75 stroke 154 100 stroke 192 125 stroke 226 150 stroke 250 Rod end nut is included in the weight. Construction (Not able to disassemble.) Component Parts No. q w e r t y u No. i o !0 !1 !2 !3 !

(The value will be 7 s for the temperature sensor output.) 7: When the temperature sensor is used, it will be 250 VAC. 8: The Device ID varies depending on the product No.

(Including insulating material) 1.27 mm 2.35 mm Connection type Screw tightening Rated current 4 A 8 A 9 A Rated voltage 60 V 600 V 250 V Contact resistance 5 mW or less Insulation resistance 100 MW or more Withstand voltage 1.0 kV 1.4 kV 4 kV Rating/Performance temperature Connector 25 to +90C 25 to +80C 25 to +85C Cable 25 to +80C 10 to +105C Ambient Min. bending radius (Fixed) 59 mm

Station n L1 L2 Station 2 78 50 Station 20 438 410 3 98 70 4 118 90 5 138 110 6 158 130 7 178 150 8 198 170 9 218 190 10 238 210 11 258 230 12 278 250 13 298 270 14 318 290 15 338 310 16 358 330 17 378 350 18 398 370 19 418 390 1-5-68 5 Port Solenoid Valve Rubber Seal Series SYJ7000 Type 42: Side Ported/SS5YJ7-42Stations C6,N7 C8,N9 [ ]: AC Grommet (G) 122 [126.4] Approx. 300 (Lead wire length

, 300, 350 12 13 107 44 20 16 47 64 148 M8 35 64 19 50 11 7 14 115 49 20 16 50 78 162 M10 38 77 19 63 16.5 16.5 13.5 6.5 16.5 Bore size (mm) J K L MM ML NN OA OB OL P PA PB PW Q R S T U VA 18 M8 x 1.25 7.5 M8 x 1.25 27 27 40 20 6.6 11 1/8 38 30 104 44 118 86 106 40 13 21.5 9 M10 x 1.5 9 32 32 46 22 8.6 14 1/4 47 40 130 60 146 110 130 50 M10 x 1.5 14 28 39 39 58 22 8.6 14 1/4 55 50 130 70

198 225 235.5 169.5 209 237.5 248 180.5 220 250 260.5 57 Manifold Specification Sheet Series VQ1000/Flip, Plug-in Unit 1.

A B ZP3EB-Y2JB10 65 125 ZP3EB-Y2JB30 90 150 ZP3EB-Y2JB50 110 170 486 B ZP3E Series Ball Joint Assembly/Unit Part No. Ball Joint Assembly Part no. ZP3EA-F1-AL6 [Weight: 27.3 g] Part no.

209 250 E Note 1) A 40 50 65 70 88 90 J 26 28 36 38 45 56 Model XLC-16 XLC-25 XLC-40 XLC-50 XLC-63 XLC-80 12 11 11 11 11 39 63 68 69 96 95 110 Note 1) Dimension E applies when heater option is included.

36 45 63 35.5 40 57 VXF2150 VXF2160 VXF2280 32.5 38 49 20 20 23 30 30 35 23 23 25 113 127 162 103 118 152 33 37 28 1 1 1 2 4.1-94 VXF Conduit: C VXF2150, 2160 VXF2280 Conduit K 39 N 96 39 41 Model VXF2150 110 144.5 VXF2160 VXF2280 DIN connector: D VXF2150, 2160 VXF2280 DIN connector K 59 N 96 59 60 Q 45 110 144.5 Model VXF2150 45 48 VXF2160 VXF2280 VX VNl VQ Conduit terminal: T VXF2150,

209 250 E Note 1) A 40 50 65 70 88 90 J 26 28 36 38 45 56 Model XLC-16 XLC-25 XLC-40 XLC-50 XLC-63 XLC-80 12 11 11 11 11 39 63 68 69 96 95 110 Note 1) Dimension E applies when heater option is included.

DIHerMI 15 90 ,00 11 0 With 2 surface D-85 sWitches Same 75 90 '00 surface 110 D-B6 DiHerem jS+5~ go+l ~ D-GS l DO+'~r" 110... 10~ D-KS With n surface .1'1::1 .2,3,4 ... nz4.8.12. n= ...,e.l :t: n=o4,a .I 2..18. swifches Same 75..SO(~) 90+50/11-2) HlOo..so;.21 110+50 (n-2) I surface n",2,3,4, .. ~, "' .S.8 1"O:2.4,6.L n--2,4 ,6.8 ...

Operating air pressure Air discharge if no drainage 6 l (ANR) each time 0.3MPa Model Air flow capacity (l/min (ANR)) 50/60Hz IDF2D 120 140 IDF1D 85 100 IDF4D 215 250 IDF3D 180 210 10 l (ANR each time 0.5MPa 50Hz 60Hz 14 l (ANR) each time 0.7MPa Operation cycle: 1 cycle/min. Operation time: 2 sec./min. IDF220B to 370B standard.

0.8 0.7 100 2.6 2 1.6 1.4 1.2 1 0.9 110 3.5 2.6 2 1.7 1.4 1.2 1.1 www.poweraire.com 1-800-526-7661 27 Section IV: Charts Vacuum Flow Trough Orifices The chart below approximates flow that would be expected thorugh a practical orifice.