S, Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% Operating pressure (MPa) Operating direction 0.5 Bore size (mm) 0.3 0.7 181 IN 302 422 32 Standard Stroke 241 OUT 402 563 317 IN 528 739 40 (mm) Bore size (mm) Standard stroke 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 377 OUT 628 880 495 IN 825 1150 32 1 50 589 OUT 982 1370 40 50 2 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15,
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to
Note 1) C 5 to 35 Cooling capacity 50/60 Hz Note 3) kW 9.0/9.5 13.0/14.5 Heating capacity 50/60 Hz Note 4) kW 1.7/2.2 2.5/3.0 Temperature stability Note 5) C 1.0 Circulating fluid system Rated flow 50/60 Hz (Outlet) Note 6) L/min 42/56 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50/60 Hz Note 7) L/min 28/42 Tank capacity L 18 Circulating fluid
CHKGB50 CHKGB20 -5 (M) -10 (M) -15 (M) -20 (M) -25 (M) -30 (M) -35 (M) -40 (M) -45 (M) -50 (M) -75 (M) -100 (M) -5 (M) -10 (M) -15 (M) -20 (M) -25 (M) -30 (M) -35 (M) -40 (M) -45 (M) -50 (M) -75 (M) -100 (M) -5 (M) -10 (M) -15 (M) -20 (M) -25 (M) -30 (M) -35 (M) -40 (M) -45 (M) -50 (M) -75 (M) -100 (M) -125 (M) -150 (M) -5 (M) -10 (M) -15 (M) -20 (M) -25 (M) -30 (M) -35 (M) -40 (M) -45 (M
D -DIN DS -DIN with surge voltage suppressor DL -DIN with light DZ -DIN with surge voltage suppressor and light DO-For DIN (without connector) Connector 1 2 3 4 5 6 7 8 J 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz Refer to the table (3) shown below for availability.
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 42 50 54 64 63 K 5.5 5.5 6 7 7 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Standard stroke (mm) 5, 10 5, 10 5, 10, 15, 20 5, 10, 15, 20 5, 10, 15, 20 M5 x 0.8
/Y7PV D-Y7W/Y7WV D-Y7BA D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA 5 5 5 5.5 5.5 5 5 5 5.5 5.5 Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63.
Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC [115 VAC] (50/60 Hz) 220 VAC [230 VAC] (50/60 Hz) 24 VDC 12 VDC 8 Series VQZ100/200/300 Made to Order (For details, refer to page 34.)
8 and @7 20 P523030-5 50 P523040-5 70 P391050-5 100 P391060-5 200 P523010-5 Seal kit P391070-5 17 Rotary Table Series MSQ Dimensions/Size 10, 20, 30, 50 WB effective depth WC XB effective depth XC Basic type/MSQBA 8-WD depth WE (Circumference: 8 equivalents) XA 2 WA 2 4-JJ depth 8 45 2-J through JA depth of counter bore JB 22.5 BE WF 2-M5 x 0.8 Piping port (Plugged) BD Effective depth FB
100 VAC, 50/60 Hz 200 VAC, 50/60 Hz Nil N T F Standard Rc Nil Z None With light/surge voltage suppressor NPT 1 110 VAC, 50/60 Hz Option NPTF S With surge voltage suppressor 220 VAC, 50/60 Hz G 2 position double 5 6 9 24 VDC 12 VDC Note) Indicator light is not available for grommet type.
force [%] Duty ratio [%] Continuous pushing time [minute] 70 100 LEY -X5 80 70 10 11LEFS 100 50 5 11LEJS LEPY10 (Basic) LEPY10L (Compact) 25A50 60 LEC 50 LEC S 40 Lead 5 (LEPY10K) Lead 5 (LEPY10LK) LEC SS-T 40 30 Force [N] Force [N] LEC Y 30 20 Motorless Lead 10 (LEPY10J) Lead 10 (LEPY10LJ) 20 10 LAT 10 LZ 0 0 60% 70% 80% 90% 100% 50% 60% 70% 80% 90% 100% LC3F2 Set value of pushing force
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to
5 100 5 100 1 10 150 10 150 10 150 10 150 2 15 200 15 200 15 200 15 200 3 20 300 20 300 20 300 20 300 4 25 400 25 400 25 400 25 400 5 30 500 30 500 30 500 30 500 6 35 600 35 600 35 600 35 600 7 40 700 40 700 40 700 40 700 8 45 800 45 800 45 800 45 800 9 50 900 50 900 50 900 50 900 10 55 1000 55 1000 55 1000 55 1000 11 60 1200 60 1200 60 1200 60 1200 12 65 1400 65 1400 70 1400 70 1400 13 70
AC/Class B coil (Built-in full-wave rectifier type) DC 1 5 G N 1 1 G N R VX02 VX02 Series Series Rated voltage Note) 1 2 3 1 2 3 VX31 VX32 VX33 VX31 VX32 VX33 1 2 3 4 7 8 J 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz Rated voltage Note) 5 6 24 VDC 12 VDC Note 1) Refer to Table (1) for available combinations.
H I J K Stroke 5 5 D C 20 +38 +10 +28 I 30 +48 +20 40 +84 +30 +54 50 +94 +40 J H F Width across flats 7 Hexagon width across flats 12 M8 x 1.25 Y 2.5 A B Stroke 20 to 50 mm Dimensions: 10 mm Stroke (mm) A B C D F H I J Y Model ZPT40F10-B01-A14 40 43 12.5 18.5 39 51.5 118 5 50 ZPT50F10-B01-A14 50 53 13.5 19.5 40 52.5 119 6 Additional Dimensions by Stroke (mm) I J H Stroke 20 +10 +5.5 0 30
8 and @7 20 P523030-5 50 P523040-5 70 P391050-5 100 P391060-5 200 P523010-5 Seal kit P391070-5 11-9-20 21 Rotary Table Series MSQ Dimensions: Size 10, 20, 30, 50 WB effective depth WC XB effective depth XC Basic type: MSQBA 8-WD depth WE (Circumference: 8 equivalents) XA 2 WA 2 4-JJ depth 8 45 2-J through JA counterbore depth JB 22.5 CRB2 BE CRBU2 CRB1 WF 2-M5 x 0.8 Piping port (Plugged)
Straight connector type Angle connector type 15 Series SV EX500 Decentralized Serial Wiring Options 1in = 25.4mm Power cable with connector EX500 AP S 050 Cable length (l) Connector specifications 1m (3.24ft) 5m (16.2ft) Straight Angle 010 050 S A M12 M12 6 6 28.3 18 30 5 50 l 31.3 14.9 30 5 34 50 48 l 5 1 2 1 2 5 4 3 4 3 Socket connector pin arrangement Socket connector pin arrangement