Table 3.1-1 Weight of the product Model Weight kg Option increase HRL100-A-40 Approx.240 Option-D1:+1kg HRL200-A-40 Approx.260 Option-T2:+1kg HRL300-A-40 Approx.330 Option-T3:+18kg* HRL100-W-40 Approx.250 HRL200-W-40 Approx.250 *Applicable only to HRL300-A*-40. 3.1 Transport HRL Series 3-2 HRX-OM-X037 Chapter 3 Transport and Setting Up 3.1.2 Transportation using casters This is a heavy product
N.O. 140 (80) 1/8 Base mounted (with sub-plate) 135 (75) 136 (76) 157 (97) V100 1/4 Note) Value for DC. Add 3 g for AC. ( ): Without sub-plate.
(For DZ) Manual override (Non-locking push type) E Pilot port 12(P1), 10(P2) Port size: refer to table below C K (External pilot solenoid) P1 P2 J J B (Air operated) D 4 x 2 x 18 mouting hole 32 H F A Applicable flange Port 1, 2 Pilot port 12(P1), 10(P2) A Model B C D E F H J K Note) VNC5-32F VNC6-40F VNC7-50F 1 8 1 4 1 4 32 40 50 292.5 (294.5) 308 (310) 332 (334) 130 150 180 210.5 226 250
Series CQ2 Compact Cylinder: Large Bore Size Type Double Acting, Single Rod 125, 140, 160, 180, 200. How to Order . Precautions. Specifications. Construction. Dimensions . Series CQ2W Compact Cylinder: Large Bore Size Type Double Acting, Double Rod 125, 140, 160, 180, 200 . How to Order . Precautions. Specifications. Construction. Dimensions .
FH FH 140 70 HOW 215 42 20 Hexagon socket head cap screw (M6 x 10) 4 pcs. Handling Precautions Mounting q The flat portion of the stainless steel cover functions as the contaminant adsorption surface.
Less Than 0.64 SCFM (18 Nl/min) at 70 psi (5 kgf/cm'Z) Supply Output Flow Rate 8.8 SCFM (250 Nl/min) at 70 psi (5 kgf/cm':) Supply Ambient Temperature and Temperature of Working Air 14" 140"F (-10 60"C) Range of Angular Adjustment 0'-90'CW or 0"-90" CCW (adjustable range 0 -60 to 0q95') Port Size 1/4" (all ports) Raw lvlaterial of l\4ain Parts Aluminum Die-cast, Stainless Steel, Brass, Nitrile
Supp Output Flow Rate 8.8 SCFM (250 Nl/min)at 70 psi (5 kgf/cm'?)
Supp Output Flow Rate 8.8 SCFM (250 Nl/min)at 70 psi (5 kgf/cm'?)
0.94 340 1/8 90 0.7 250 0.94 340 1/4 115 2.3 810 2.3 810 1/4 130 2.3 810 2.3 810 3/8 124 0.2 4.6 1,670 4.6 1,670 1/4 221 0.35 4.6 1,670 4.6 1,670 3/8 214 4.6 1,670 4.6 1,670 1/2 205 7.9 2,840 7.9 2,840 1/4 242 11.9 4,270 11.9 4,270 3/8 233 11.9 4,270 11.9 4,270 1/2 224 Note) Flow rate values are measured at 0.5 Mpa and 20C.
Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.
Multistage Ejector (N)ZL112 with Valve and (N)ZL212 Large Flow Type (N)ZL Series 3 Stage Construction Optional Supply & Release Valves Optional Pressure Sensors Series (N)ZL Multistage Ejector Energy saving, high flow, 3 stage diffuser construction Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, single stage model) 1 stage
248 203 220.5 250 260.5 213.5 231 262.5 273 65 5 Port Solenoid Valve Series VQ1000/2000 VQ2000/Flat Cable Kit with Terminal Block Stations VV5Q21GU0-(D) Broken lines and dimensions inside ( ) indicate type [-D] (with DIN rail mounting bracket).
1 EJECTOR MULTISTAGE Multistage Ejector Series ZL112/212 Energy-saving, large flow rate, 3 stage diffuser construction ZX Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage perf stage perfor ormance mance 1 stage performance Vacuum pressure ZR Q1 Q2 Q3 ZM Q1 Q2 Q3 Maximum suction flow rate (l/min (ANR))
135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 251.1 266.6 290.6 292.5 308 332 32 40 50 573 A VNB Series Specific Product Precautions Be sure to read this before handling the products.
588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.5 1 Point of application L Workpiece weight m kg 0.1 Transfer speed V m/min 30 20 10 5 5 30 20 10 Transfer speed V (m/min) Transfer speed V (m/min) MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 30 20 100 L = 120 mm L = 100 mm L = 80 mm L = 60 mm L = 40 mm 40 L = 240 mm L = 200 mm L = 160 mm L = 120 mm L = 80 mm L = 180 mm L = 140
151 162 176 193 212 178 204 63 MGTL 199 212 226 243 170 186 127 143 MGTM 199 213 228 246 267 291 221 250 80 MGTL 180 192 205 220 237 255 154 62 MGTM 271 288 307 328 353 382 321 356 100 F MGTL 242 257 274 292 313 335 153 114 8-24-5 6 Series MGT Construction o !
Mounting pitch A Fig. 1 Recommended piping Unit: mm R20 or less Tubing size Mounting pitch A Straight line length Nylon tubing Soft nylon tubing Polyurethane tubing 1/8" 44 or more 29 or more 25 or more 16 or more 6 84 or more 39 or more 39 or more 30 or more 1/4" 89 or more 56 or more 57 or more 32 or more 8 112 or more 58 or more 52 or more 40 or more 10 140 or more 70 or more 69 or more
140 115 218 150 60 90 77.8 42.9 42.9 77.8 21.5 10 21.5 2B 2 1/2B M16 x 2 Thread depth 34 M16 x 2 Thread depth 34 300 170 150 268 180 80 120 106.4 61.9 61.9 106.4 21.5 10 21.5 3B 3 1/2B M16 x 2 Thread depth 30 M16 x 2 Thread depth 30 280 145 140 273 210 80 120 130 78 78 130 20 5 20 4B Weight (kg) S T U V W X Model Threaded without flange With flange FH990-04 FH990-06 FH990-08 FH990-10 FH990
100 Pressure 0.6 MPa Pressure 0.6 MPa 30 0.5 0.5 80 25 Gripping force (N) External grip Gripping force (N) 0.4 0.4 60 20 0.3 0.3 15 40 0.2 0.2 10 20 0.1 0.1 5 L L 0 20 30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 700 180 Angular Type Air Gripper MHY2/MHW2 Series MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 250
20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 MHR 200 0.5 0.5 0.5 60 15 0.4 0.3 150 0.4 0.4 MHK 40 10 0.3 0.3 100 0.2 0.2 0.2 MHS 5 20 50 MHC 0 0 40 Gripping point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHT MHW2-25D MHW2-40D 160 50 MHY Pressure 0.7 MPa Pressure 0.7 MPa 140 0.6 0.6 40 Gripping force