Metric sizes Type 4 6 8 10 12 04 06 08 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 x 0.8 1/8 1/4 3/8 1/2 M5 01 02 03 04 With One-touch fitting Clean specification Metal part material Q G Brass (electoless nickel plated) Stainless steel (SUS304) Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06
Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15
How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.
8 for details. 711 AS-FPQ/FPG Series How to Order AS 2 1 1 2 F P Q 01 06 Lock nut option Nil J Body size Hexagon lock nut Round lock nut 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.
8 for details. 711 AS-FPQ/FPG Series How to Order AS 2 1 1 2 F P Q 01 06 Lock nut option Nil J Body size Hexagon lock nut Round lock nut 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: S (Bracket (mounting position: Stream side)), Operation Manual/Calibration Certificate: K
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with Operation
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: S (Bracket (mounting position: Stream side))
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only), Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with Operation
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: T (
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: C6 (6mm), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: C6 (6mm), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with Operation
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: M (SI units only)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with Operation Manual
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side)), Operation Manual/Calibration Certificate: K (with
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: K (with Operation Manual and Calibration Certificate
Metric sizes Type 4 6 8 10 12 04 06 08 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 x 0.8 1/8 1/4 3/8 1/2 M5 01 02 03 04 With One-touch fitting Clean specification Metal part material Q G Brass (electoless nickel plated) Stainless steel (SUS304) Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06