SMC Corporation of America
Elite Part Number Search
Search Results "NCA1B150-1000+1200-XC10"

Water bath Q = T x V x x C h x 60 x 1000 10 x 2 x 1 x 103 x 4.2 x 103 20C V = 15 x 60 x 1000 After 15 min, = 93.3 W cool 30C down to 20C.

CN1IF (CONT) 19 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SW OFF RWw(n+1)b0 ON(1) (LEC) (LEC)(LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB ) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.CN2TB/PC () 20 - .CN4 6.1 1 EMG+ EMG 2 EMGEMG 3 24V 5 4 3 2 1 () 4 0V 5 FG FG (LEC)(0V)

VCHC ASR ASQ ASD230F ASD330F ASD430F 100 200 400 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 07,08,09,10,11 300 06 200 50 100 100 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530F ASD630F 1500 1000 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 12 10,11 10,11,12 08,09 1000 500 06,07 500 0 5 10 0 5 10

VCHC ASD230FG ASD330FG ASD430FG ASR ASQ 100 200 400 07,08,09,10,11 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 300 06 200 50 100 100 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530FG ASD630FG ASD530FG ASD630FG 1500 1000 10,11 12 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 10,11,12 08,09 1000 500 06,07

The maximum detectable piston speed is: Auto switch operating range (mm) _ Time load applied (ms) Operating current of load (OFF condition) > Leakage current V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.

Flow Direction Symbols on Body Meter-out type Meter-in type Flow Rate and Effective Area Symbol JIS Symbol ASD230F ASD330F ASD430F ASD530F ASD630F Model 6 8 10, 12 10 12 Metric size 4, 6 8, 10 1/8" 5/32" 3/16" 1/4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min}

14 Effective area (mm2) Effective area (mm2) 20 12 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-85 12 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F02 Component Parts No.

Effective area (mm2) Effective area (mm2) 14 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 20 12 12 10,11 10, 11, 12 08, 09 1000 10 15 8 500 06, 07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-53 12 Series ASD-FG Construction ASD230FG ASD330FG/430FG ASD530FG/630FG ASD530FG-02 @1 !

Effective area (mm2) Effective area (mm2) 14 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 20 12 12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-101 11 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F-02 !

1200 Exhaust flow rate l/min (ANR) 1MPa = 145 psi 1 l/min = 0.035 SCFM Viewing the graph: When using AMP320 at a flow rate of 500l/min, the upstream pressure is 0.037MPa. 1m = 3.28 ft. 6 Safety Instructions Series AMP These safety instructions are intended to prevent a hazardous situation and/or equipment damage.

Symbol indication of flow direction on the body Meter-out Meter-in Air Flow/Effective Area Symbol JIS Symbol ASD230F ASD330F ASD430F ASD530F ASD630F Model 6 8 10, 12 10 12 Metric 4, 6 6 8, 10 6, 8 1/4" 5/16" 3/8" 1/8" 5/32" 3/16" 1/4" Tube O.D. 1/4" 5/16" 3/8" 3/8" Inch 500 600 700 1200 1300 175 295 350 75 Air flow (l/min(ANR)) Controlled (free)/Flow 7.6 9.1 10.7 18.3 19.8 1.1 2.7 4.5 Eff

Flow direction symbols on body Meter-out type Meter-in type Flow Rate and Effective Area Symbol JIS symbol ASD230FG ASD330FG ASD430FG ASD530FG ASD630FG 4, 6 Model 6 8 10, 12 10 12 8, 10 6 6, 8 Metric size 1/4" 5/16" 3/8" Tube O.D. 1/8" 5/32" 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size l/min (ANR) Flow rate Controlled (Free) flow 295 350 75 175 500 600 700 1200 1300 4.5 5.3 2.7 1.1 7.6 9.1

1200 Exhaust flow rate l/min (ANR) Viewing the graph: When using AMP320 at a flow rate of 500l/min, the upstream pressure is 0.037MPa. 4 Series AMP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS VS4 VQ7 EVS Large capacity EVS7-6 (Size 1) 1200 l/min (ANR) EVS7-8 (Size 2) 3000 l/min (ANR) EVS7-10 (Size 3) 5500 l/min (ANR) VFN Cylinder driving size Flow rate 100 160 200 Rubber seal, single type Lightweight Size 1 (3 position): 0.55 kg Size

Piston Note 3) speed H (High speed/ High frequency type) 5 to 3000 mm/s (Refer to page 20.) 250 cm3/min or less 300 cm3/min or less 150 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 1000 cm3/min or less 1200 cm3/min or less 800 cm3/min or less Supply pressure 0.3 MPa 2500 cm3/min or less 3000 cm3/min or less 1500 cm3/min or less Supply pressure 0.5 MPa Note 1) Value when

1000 400 200 100 Transmission rate [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Lower-level bus Core cross-section 0.34mm2 or more Wire diameter 0.64mm or more 10 11 The wirings are described in the following order.

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Long stroke option: up to 3000 mm (XB11); Auto switch capable

Bore sizes: 25, 32, 40 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 5000 mm; Minimum operating pressure: 0.10 MPa (15 psi); Speed: 100~1000 mm/sec (air cushion), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 5000 mm (XB11); RoHS compliant; Auto switch capable

Bore sizes: 25, 32, 40 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 5000 mm; Minimum operating pressure: 0.10 MPa (15 psi); Speed: 100~1000 mm/sec (air cushion); Long stroke option: up to 5000 mm (XB11); RoHS compliant; Auto switch capable