Liquid dripping: 0.02 to 0.77 cm3 at each removal Aeration: 0.1 to 2.7 cm3 at each removal DM KDM KB Socket valve Plug valve KR KA KQG2 KG KFG2 MS KKA KKA KP LQ MQR T Non-greased specification (standard) Allows smooth installation and removal even without grease O-ring: Fluorine coated Sliding parts of plug and socket: Fluorine coated is used.
37 AN20-02 AV3000-mS-A 49 AN30-03 AV4000-mS-A 56 AN40-04 AV5000-mS-A 92 AN500-06 Silencer (Built-in) Space saving Energy saving When switching the main valve (exhaust R low speed air supply), the flow passage to port 3 (R) is closed with the main valve.
Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) Note 3) q Facility water temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20C, r Circulating fluid flow rate: Rated flow, t Power supply: 200 VAC Note 4) q Facility water temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated flow
Applicable model HRS-DI007 HRSH090-ll-l HRS 090 (Flying-out size) (314) Measurement range of electric conductivity 2.0 to 48.0 mS/cm HRS 100/150 Circulating fluid return port (263) Set range of electric conductivity target 5.0 to 45.0 mS/cm To circulating fluid return port o i Set range of electric conductivity hysteresis 2.0 to 10.0 mS/cm HRSH 090 HRSH 090 Operating temperature range (Circulating
The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications.Stainless steel material (SUS316), Simple connection/disconnection, Compact size for tight piping areas, Accepts many styles of plastic tubing, FITTINGS, STAINLESS STEEL, CONNECTORS, MS SS MINI FITTING, PX, MS THREADS ONLY, .01732 lb, ModelDescriptionApplicationNoteMS-5ULUniversal
The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications.Stainless steel material (SUS316), Simple connection/disconnection, Compact size for tight piping areas, Accepts many styles of plastic tubing, FITTINGS, STAINLESS STEEL, CONNECTORS, MS SS MINI FITTING, BX, MS 1/8INCH, .01225 lb, ModelDescriptionApplicationNoteMS-5ATHU-3Barb
Press the button to set. 5 ms [Default setting] 20 ms 160 ms 640 ms Error Name Error Display Error Type Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Auto Switch Specifications PLC: Programmable Logic Controller Auto switch model Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Response time D-Y7BW(V)L-900 24 VDC relay, PLC 10 VDC to 28 VDC 2.5 mA to 40 mA 4 V or less 0.8 mA or less 1 ms or less Operating positionRed light is ON.
In the case of cylinders with built-in magnets, unassembled auto switch mounting brackets are packed together when shipped. 11 Series CQM Auto Switch Specifications Auto Switch Common Specifications Reed switch Type Leakage current Solid state switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less None 1 ms or less Note 2) Operating time 1.2 ms Impact resistance 300 m/s2 1000 m/s2 Note1) Connector
or above (Pulse input) Counting Speed 20 Kcps External Power Supply 12V10%, 60mA Control Output CEU1-D: NPN (30VDC, 50mA) CEU1P-D: PNP (30VDC, 50mA) Output Mode Comparison/hold/one-shot (100 ms fixed) Supply Voltage 24VDC 10% Output Delay Time 5 ms max Power Consumption 10VA Weight 250g H O W T O O R D E R S E E N E X T P A G E A P P L I C A T I O N S S E E N E X T P A G E Courtesy of
. = b contact) state auto switches such as D-F9G and D-F9H. 14 Series CXSJ Auto Switch Common Specifications Auto Switch Common Specifications Type Reed switch Solid state switch Leakage current 3-wire: 100 A or less; 2-wire: 0.8 mA or less None Operating time 1.2 ms 1 ms or less Impact resistance 300 m/s2 1000 m/s2 Insulation resistance 50 M or more at 500 VDC (between lead wire and case
MS-DOS is a registered trade mark of Microsoft Corporation. Pentium is a trade mark of Intel Corporation.
VZ
Outstanding response times and long service life
Pressure Momentary change P1 P2 Set values t (ms) t (ms) Time Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.
rate range Rated flow range Minimum set unit Water 1.7 to 17.0 l/min 0.35 to 4.5 l/min 3.5 to 45 l/min 7 to 110 l/min 1.7 to 17.0 l/min 0.35 to 4.5 l/min 3.5 to 45 l/min 7 to 110 l/min 2 to 16 l/min 0.5 to 4 l/min 5 to 40 l/min 10 to 100 l/min 0.1 l/min 0.05 l/min 0.5 l/min 1 l/min 0.1 l/pulse 0.05 l/pulse 0.5 l/pulse 1 l/pulse Accumulated pulse flow rate exchange value (Pulse width: 50 ms
or less 2) 1.2 ms Operating time Note 1) Electrical entry: Connector type (A73C/A80C) and A9/A9V type: 1000 VAC/min.
4E)-Ms, B3r Stationsn ) 2 6 a 9 '10 ll 13 14 16 t8 19 20 L-l 1.47 (47.5)2.24 2.70 (58) (68.5)(79) (89.5)3.94 000) 4.35 (n0.5) 4.76 \121) 5.18 03I.5) 5.59 (142) 6.00 (152.5) 6.42 0631 6.A3 (173.5) 7 .24 (184) 7.66 (194.5) 4.07 (205) 4.48 (215.5) 8.90 \2?6) 9.31 (236.s) u 1.56 (39.5)1.97 (50) 2.38 (60.5)2.& (?
Prassuro 1s0 PSIG (9.9 Kgflcm ) Prool Pr333ure 225 PSIG (15 Kgr cm ) Amblnl Temp. 40 120"F (5 50"C) Responsg Tlme 30 ms Max. 50 ms Max. 30 ms Max. 50 ms Max, Hysteresls 3% F.S. Repeatablllty 3/. Sensitivity o.5/.