Cable specifications are the examples when using the product at a continuous allowable operating temperature of 70 oC, with an operating voltage of 600 V and two kinds of plastic insulated wires at an ambient temperature of 30 oC. Please select the proper size cables according to the actual condition.
-color display) 5 V,12 V 2-wire 12 V Water resistant (2-color display) . . .
NPN) Z76 5 V Reed switch Solid state switch IC Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V 12 V Relay, PLC 100 V, 200 V 2-wire 24 V Diagnostic indication (2-color) Grommet 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC Grommet 100 V, 200 V 12 V 2-wire 3-wire (NPN) 3-wire (PNP) IC Relay, PLC 5 V, 12 V Diagnostic indication (2-color) 12 V 2-wire 24 V Water
NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) Reed switch Solid state switch A96V A96 5 V IC Yes Yes Grommet A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 100 V 24 V 12 V Relay, PLC 5 V, 12 V IC 12 V 5 V, 12 V IC Relay, PLC 24 V Grommet 12 V Diagnostic indication (2-color) 5 V, 12 V IC 12 V 2-wire
NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) Reed switch Solid state switch A96V A96 5 V IC Yes Yes Grommet A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 100 V 24 V 12 V Relay, PLC 5 V, 12 V IC 12 V 5 V, 12 V IC Relay, PLC 24 V Grommet 12 V Diagnostic indication (2-color) 5 V, 12 V IC 12 V 2-wire
-color display) 5 V,12 V 2-wire 12 V Water resistant (2-color display) . . .
Examplet compressor delivery 600 cfm (free air) and an output pressure of 100 psi, What size reciver is rquired? v=l t P"p1 + 147 Where V = capacity of rceiver Q = compressor outpul (clm) Pa = atmosphric plsssurc P1 = compressor outsul pressure V = (600'14.7y(10O+14.7) =77lf as a minimum number, a prudent suggestion might begin with 120 ft".
V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 195 Thermo-chiller Basic Type HRSE Series
DC(+) DC(+) OUT1 OUT1 DC(-) DC(-) / / Max.80 mA 1.5 V E 15 V 1 k F420 mA 12 V 300 24 V 600 Max.28 V80 mA 1 V C 15 V 1 k D420 mA 12 V 300 24 V 600 -18No.PF-OMN0011CN-C NPN PF3W30G PNP PF3W30H DC(+) DC(+) OUT1 OUT1 DC(-) DC(-) / / Max.80 mA 1.5 V 30 ms Max.28 V80 mA 1 V 30 ms 2 PF3W30J/PF3W30K DC(+) DC(-) / J15 V 1 k K420 mA 12 V 300 24 V 600 -19No.PF-OMN0011CN-C
type PF3W30D PF3W30F Max. 28 V, 80 mA Internal voltage drop 1 V or less C: Analogue output 1 to 5 V Max. 80 mA Internal voltage drop 1.5 V or less E: Analogue output 1 to 5 V Output impedance 1 k Output impedance 1 k D: Analogue output 4 to 20 mA F: Analogue output 4 to 20 mA Max. load impedance Max. load impedance When power supply is 12 V: 300 When power supply is 24 V: 600 When power
Cooling tower 127 P Compliant with safety standard for medical equipment IEC 60601-1 (Air-cooled/HEC002-A series) P Power supply: Applicable to 100 V to 240 V (Air-cooled/HEC-A series,Water-cooled/HEC001-W, HEC003-W) P Suitable to fluorinated fluids (Fluorinert TM FC-3283, GALDEN HT135) (Water-cooled/HEC006-W, HEC012-W) P Compatible with ethylene glycol 20% (Water-cooled/HEC001-W, HEC003-
V: 600 Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 NPN + External input type PNP + External input type PF3W7--GPF3W7--HMaximum 28 V, 80 mA Internal voltage drop 1 V or less External input: Voltage free contact Maximum 80 mA Internal voltage drop 1.5 V or less External input: Voltage free contact Reed or solid state input 30 ms minimum duration Reed or solid state input
IDX-OM-V022-H Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V This manual is intended to explain the installation and operation of the product.
Max.80 mA 1.5 V NPN PF3W7--C(T)NPN PF3W7--D(T)PNP PF3W7--E(T)PNP PF3W7--F(T)Max.80 mA 1.5 V E15 V 1 k F420 mA 12 V 300 24 V 600 Max.28 V80 mA 1 V C15 V 1 k D420 mA 12 V 300 24 V 600 NPN PF3W7--GPNP PF3W7--HMax.28 V80 mA 1 V 30 ms Max.80 mA 1.5 V 30 ms -22No.PF-OMM0004-D NPN2 PF3W7--A(T)NPN PF3W7--C(T)PF3W7--D(T)NPN PF3W7--GPNP2 PF3W7--B(T)PNP PF3W7--E(T)PF3W7--F(T)PNP PF3W7
mA Internal voltage drop 1 V or less Max. 80 mA Internal voltage drop 1.5 V or less NPN + Analog output type LFElClll NPN + Analog output type LFElDlll Brown DC (+) Load Black OUT1 Main circuit 24 VDC White Analog output Load Blue DC () Max. 28 V, 80 mA Internal voltage drop 1 V or less C: Analog output 1 to 5 V Output impedance 1 k D: Analog output 4 to 20 mA Load impedance 50 to 600 Accumulated
Start time of circulating fluid temperature monitor 600 0 to 9 TEMPOUTSTART SEC No.24 circulating fluid temperature monitor is outside of the time range 5 0 to 600 TEMPOUTOVER SEC screen No.25 screen Dust filter replacement time*2 5000 1 to 9 FLTRTIME H No.26 screen DI filter replacement time*1 5000 1 to 9 DITIME H No.27 screen Temperature control speed 0 -10 to 10 CTRLSPEED DI water piping
Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical
Y69B Y7NWV Y7PWV Y7BWV IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Relay, PLC Diagnostic indication (2-color indication) 5 V, 12 V Grommet 24 V 2-wire 12 V Water resistant (2-color indication) Y7BA Solid state switches marked with are produced upon receipt of order.
X B 5 S T D.R O D T H R E A D S T D.R O D B O R E S I Z E 3/4-16 1-14 1-14 1 1-3/8 1-3/8 500 5 600 6 800 8 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please contact P/A Customer Service for larger sizes R E F E R TO PAG E 22 F O R O P T I O N A L RO D T H R E A D S 3 Dimensional Drawings Expanded Series NCA1 MF1 1.5 ~ 6 WITH FRONT RECTANGULAR FLANGE BORE ROD KK A B V W Y ADD STROKE MM SM
Load impedance Maximum load impedance at power supply voltage of 12 V: 300 at power supply voltage of 24 V: 600 Minimum load impedance: 50 Input type Non-voltage input: 0.4 V or less Input mode Select from Auto-shift or Auto-shift zero.