SMC Corporation of America
Elite Part Number Search
Search Results "LMU200-53"

GA H2 NN NN GB H1 MM I ND D NB NE C Effective Thread E E NF N JC 10 10 N JD A K F NA S+Stroke F H B WH ZZ+Stroke (mm) Stroke range (mm) 200 to 700 200 to 700 200 to 1000 200 to 1000 Bore (mm) 20 25 32 40 Eff. thread length 15.5 19.5 19.5 21 H1 5 6 6 8 H 44 48 51 54.5 GB 47.5 49.5 51.5 51.5 GA 53.5 56.5 55 56 F 16 16 19 21 E 14.5 18 18 20.5 D 10 12 12 16 C 40.5 45.5 51.5 61.5 B 32 36 44 53

No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.

5.19.1 Communication function . 5-53 5.19.2 Communication function setting and checking . 5-53 Chapter 6 OptionOptional Accessories . 6-1 6.1 Option J [Automatic fluid filling] . 6-1 6.1.1 Option J [Automatic fluid filling] . 6-1 6.2 Option M [DI water (Pure water) piping] . 6-2 6.2.1 Option M [DI water (Pure water) piping] . 6-2 HRS Series HRX-OM-R016 Contents 6.3 Option T [High-pressure

5.19.1 Communication function . 5-53 5.19.2 Communication function setting and checking . 5-53 Chapter 6 OptionOptional Accessories . 6-1 6.1 Option J [Automatic fluid filling] . 6-1 6.1.1 Option J [Automatic fluid filling] . 6-1 6.2 Option M [DI water (Pure water) piping] . 6-2 HRS Series HRX-OM-O021 Contents 6.2.1 Option M [DI water (Pure water) piping] . 6-2 6.3 Optional Accessories [

5.19.1 Communication function . 5-53 5.19.2 Communication function setting and checking . 5-53 Chapter 6 OptionOptional Accessories . 6-1 6.1 Option J [Automatic fluid filling] . 6-1 6.1.1 Option J [Automatic fluid filling] . 6-1 6.2 Option M [DI water (Pure water) piping] . 6-2 HRS Series HRX-OM-R005 Contents 6.2.1 Option M [DI water (Pure water) piping] . 6-2 6.3 Optional Accessories [

(Unit:mm/s2) Refer to (1) to (5) on page 53 for acceleration speed setting for movement mode. Acceleration 1 to Max ACC/DEC in the basic parameters Set the deceleration from travel speed to stop. (Unit:mm/s2) Refer to (1) to (5) on page 53 for deceleration speed setting for movement mode.

Electric actuators/Common precautions .49 15.1 Design and selection .49 15.2 Mounting.50 15.3 Handling.51 15.4 Operating environment .52 2 - 15.5 Maintenance .53 15.6 Precautions for actuator with lock.53 16.

JXC-OMT0002-C Description Input range Explanation Stroke (-) to Stroke (+) in the basic parameters Set the target position (Unit: mm) Refer to (1) to (5) on page 53 for position setting for movement mode. Position Set the acceleration to reach to travel speed. (Unit:mm/s2) Refer to (1) to (5) on page 53 for acceleration speed setting for movement mode.

Bore size [mm] B DA DB DL DU DC DX DE DO DR DT DS DH Z DD H10 Bore size [mm] Z MB-B03 32 46 42 32 22 10 44 14 62 9 6.6 15 7 33 154 10+0.058 0 40 52 42 32 22 10 44 14 62 9 6.6 15 7 33 158 10+0.058 0 32 160 40 164 50 190 63 190 80 238 100 238 125 279 MB-B05 50 65 53 43 30 11.5 60 20 81 10.5 9 18 8 45 182 14+0.070 0 63 75 53 43 30 11.5 60 20 81 10.5 9 18 8 45 182 14+0.070 0 MB-B08 80 95 73 64

Bore size B DA DB DL DU DC DX DE DO DR DT DS DH Z DD H10 32 219 40 237 50 268 63 280 80 351 100 371 MB-B03 32 46 42 32 22 10 44 14 62 9 6.6 15 7 33 213 10+0.058 0 40 52 42 32 22 10 44 14 62 9 6.6 15 7 33 231 10+0.058 0 MB-B05 50 65 53 43 30 11.5 60 20 81 10.5 9 18 8 45 260 14+0.070 0 63 75 53 43 30 11.5 60 20 81 10.5 9 18 8 45 272 14+0.070 0 MB-B08 80 95 73 64 45 14 86 30 111 12.5 11 22 10

Replacement part type L shows the parts for LQ-GL and LQ-GM. 33 High Purity Fluoropolymer Fittings & Tubing Series LQ1 2 Dimensions LQ-GJ LQ-GK LQ-GJ 36 30 45 (adjustable) 117 76 24 LQ-GK 36 SET POS. 53 127 43 63 (Max. 50) 114 53 43 63 LQ-GM LQ-GL 50 50 207 85 342 85 LQ-GL 40 28 SET POS. 40 28 LQ-GM 4-R3 SET POS. 6 6 4-R3 6 6 4-R3 4-R3 (Max. 91) 325 (Max. 91) 191 87 60 87 60 112 112 34 Series

Applicable Applicable Model D1 L1 L2 P Q A M Minimum Tube OD Fitting Size Hole Applicable Applicable Model D1 L1 L2 P Q A M Effective Tube OD mm Fitting Size Orifice (mm2) Inch d Diameter d Nylon/Urethane 1/8 3.2(1/8) KQU01-99 9.6 52 17.5 9.6 9 36.5 15.5 2 3.2 3.2 KQU23-99 9.6 52 17.5 9.6 9 36.5 15.5 3.4/2.9 5/32 4(5/32) KQU03-99 10.4 53 18 10.4 9.7 37 16 2.5 4 4 KQU04-99 10.4 53 18 10.4

32 135 35 60 80 50 32 75, 100, 125, 150 200, 250, 300 MGT 125 107 19 16 160 176 110 125 9 12 85 165 M8 37 160 40 70 95 60 38 150 142 25 19 190 210 115 135 11 12 95 200 M10 42 194 45 82.5 115 75 50 Bore size (mm) P Note 2) Q R S T U V W WH X Y Z O 20 25 32 40 50 86 80 M6 x 1 M5 x 0.8 21 12 26 12 40 36 30 140 23 M6 x 1 M5 x 0.8 21 12 31 13 98 47 44 37 80 153 25 M6 x 1 1/8 21 12 38 16 112 53

53 77 114.5 125 Use a thin wrench when tightening the piston rod.

D E Note) DIN rail mounting style Direct mounting style Option Nil 02 to 16 (1) B (2) K (3) N R S None DIN rail length specified Back pressure check valve Note) Refer to page 53 for details.

Suction flow rate Suction flow rate When obtaining the suction flow rate at a vacuum pressure of 53 kPa from the ZH07DS flow-rate characteristics graph, the suction flow rate is 5 L/min (ANR).

Suction flow rate Suction flow rate When obtaining the suction flow rate at a vacuum pressure of 53 kPa from the ZH07DS flow-rate characteristics graph, the suction flow rate is 5 L/min (ANR).

MGG MGC (mm) MGF Stroke range Bore size (mm) D1 J K M B D C E KA GA GB H MGZ 11 12 22 25 25 25 25 51 57 66 78 92 110 144 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 M12 x 1.75 8 8 10 10 14 14 20 39 43 49 59 71 82 106 29 33 38 46 55 66 86 25 30 36 45 55 68 87 11 12 16 21 26 32 36 21 24 30 36 46 53 65 16 26 28.5 34.5 40 46.5 54 20 21 35 40 45 50 50 20 25 32 40 50 63 80 12.5 18 19.5

22.5 23 22 28 26.5 22 30 33.5 29 27 34.5 30 30 Reference dimensions after R thread installation. 15.5 17 1 4 17 10.4 14 27 21 19 26 19 14 17 6 5.6 Applicable tubing 3 8 1 8 KRH06-03S 24 26.1 KRH08-01S KRH08-02S KRH08-03S KRH10-01S KRH10-02S KRH10-03S 14 1 4 3 8 1 8 1 4 3 8 20.5 15.5 26 27.5 22.5 8 18.5 18.0 17 26.1 26.1 17 30 10 21 Connection thread (With seal) 41.5 29.5 1 2 KRH10-04S 19 53

Bracket B Bracket assembly 16-2-53 10 Series ISE70/75/75H Specific Product Precautions 2 Be sure to read before handling. Set pressure range and rated pressure range Caution 1. Set the pressure within the rated pressure range. The set pressure range is the range of pressure that is possible in setting.