, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal

actuation VFN VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 Bore size Series CA1 Pressure 0.5 MPa Load factor 50% Stroke 400 mm Average speed (mm/s) Series 100 40 50 63 80 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 800 700 600 500 400 300 200

actuation VFN VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 Bore size Series CA1 Pressure 0.5 MPa Load factor 50% Stroke 400 mm Average speed (mm/s) Series 100 40 50 63 80 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 800 700 600 500 400 300 200

VDC Mega) between external terminal and case. 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal HRSH 090 HRSH To the thermo-chiller Users equipment side HRSE 7 24 VDC 6 24 VDC output (500 mA MAX) 5 HRZ 15 14 HRZD 24 VCOM output 13 24 VCOM HRW Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k HECR 11 Run/stop

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal

mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Circuit diagram Contact input signal 2 4 1 k 11 Run/stop signal input Contact input

D20Weight Rotating angle Flange (g) Basic weight (g) Add'l stroke weight (g/mm) Size 80 to 100 1400 4 500 32 170 to 190 1500 80 to 100 2100 40 5 500 170 to 190 2300 Calculation: (Example) MRQBS32-50CA Basic weight 1400 g 4 x 50 = 200 g Stroke additional weight Total 1600 g For the weight of auto switch alone, refer to page 11-11-1.

The vacuum aspiration fluence shows the fluence immediately before piping in the actuator. 5 - 3.How to Order 11LEJS 40 A 500 S2 1 10 9 8 7 4 5 3 2 6 *1 (2) Motor type (3) Lead [mm] (1) Size 40 LEJS40 LEJS63 Output [W] Actuator size Compatible controller Type 63 16 A 20 AC servo motor (incremental encoder) S2 10 8 B LECSA-S1 40 100 (5) Motor option AC servo motor (incremental encoder) S3

Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.

Insulation resistance 50 M or more under the test voltage 500 VDC (between case and cable) Withstand voltage 1000 VAC 1 min.

(between FE and all accessible terminals) Insulation resistance 10 M ohm or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z (complies

The unit conversion between SI and conventional units are as follows: Oscillation acceleration 100m/s2 = 10.1972G Pressure 1MPa = 10.1972kgf/cm2 Cylinder thrust/load 100N = 10.1972kgf Standard air: Symbol (ANR) Torque 1Nm = 10.1972kgfcm Temperature 20C {293K}, Air with Moment of inertia 1kgm2 = 10.1972kgcm/s2 an absolute pressure of 760 mmHg Kinetic energy 1J = 10.1972kgcm {101.3kPa}, and

Electrical entry Grommet Power supply voltage 12 to 24 VDC Current consumption 40 mA or less Output specification NPN open collector 2 outputs PNP open collector 2 outputs Load voltage 28 VDC or less Impact resistance 980 m/s2 Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between lead wire and case Withstand voltage 1000 VAC for 1 minute (between lead wire and case

(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).

VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized

VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized

) 49 m/s2 2 hours in each direction X, Y and Z Vibration resistance Impact resistance 147 m/s2 is applied 3 times in each direction X, Y and Z EN 60068-2-27/29 Operating environment No corrosive gas Certifications EMC directive Yes, 2014/30/EU, IEC61326-3-1 Machinery directive Yes, 2006/42/EC, EN 62061, EN ISO 13849 TUV Certification Yes, EN 61508, EN 62061, EN ISO 13849 PROFINET & PROFIsafe