SMC Corporation of America
Elite Part Number Search
Search Results "IDK04-100-C1"

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / -100 to 100 kPa / NPN 2 Outputs, Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 09 [ø5/16 One-touch Fitting (Inch)], Bracket: -, Individual Release Pressure Supply: -, Vacuum Break Flow Adjustment: -, Manifold

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / -100 to 100 kPa / NPN 2 Outputs, Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 09 [ø5/16 One-touch Fitting (Inch)], Bracket: -, Individual Release Pressure Supply: -, Vacuum Break Flow Adjustment: -, Manifold

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only, Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: -, Individual Release Pressure Supply: -, Vacuum Break Flow Adjustment

. / None, Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only, Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: -, Individual Release Pressure Supply: -, Vacuum Break Flow Adjustment

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only, Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: -, Individual Release Pressure Supply: -, Vacuum Break Flow Adjustment

Type: Straight, Material: Fluororesin, Cutting Service: Presence, Color: [Transparent (Including Non-Whites)] Translucent, Outer Diameter Class: ~4, Compatible Fluid: Air, Outer Diameter D(Ø): 4, Inner Diameter Class: ~3, Inner Diameter d(Ø): 2.5, Number of Cables(per piece): -, Material: Fluororesin: [Standard Fluororesin] Standard Fluoropolymer, Minimum Bending Radius(mm): 20, Operating

This series is available in four body sizes with piping from M5 to 3/4 in Rc, NPT or G thread types.Modular type filter regulator , Rated filtration ( m): 2, 10, 20, 40 , 70 or 100 , Optional embedded pressure gauge , Available with built-in backflow mechanism , Rc, G(PF) or NPT threads, F/R MAINTENANCE KIT, AIRLINE EQUIPMENT, AW MASS PRO, C1, AW MASS PRO 1/8 PART, .02200 lb

Model Allowable pressing load (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 5. Do not apply impact load to the center of the magnetic attraction surface. Otherwise, it may result in a breakage or malfunction. 6. The head cap is magnetized during the release of workpiece. Iron particles may be attracted. 7 - 2-3 Environment Warning 1.

Operating compressor: 0.75 kW or more, Discharged flow rate: 100 L/min (ANR) or more When using 2 or more auto drains, multiply the value above by the number of auto drains to find the capacity of the compressors you will need. For example, when using 2 auto drains, 1.5 kW (200 L/min (ANR)) of the compressor capacity is required.

Operating compressor: 0.75 kW or more, Discharged flow rate: 100 L/min (ANR) or more When using 2 or more auto drains, multiply the value above by the number of auto drains to find the capacity of the compressors you will need. For example, when using 2 auto drains, 1.5 kW (200 L/min (ANR)) of the compressor capacity is required.

This series is available in four body sizes with piping from M5 to 3/4 in Rc, NPT or G thread types.Modular type filter regulator , Rated filtration ( m): 2, 10, 20, 40 , 70 or 100 , Optional embedded pressure gauge , Available with built-in backflow mechanism , Rc, G(PF) or NPT threads, F/R MAINTENANCE KIT, AIRLINE EQUIPMENT, AW MASS PRO, C1, AW MASS PRO 1/8 PART, .02200 lb

Symbol 46 42.5 Outside diameter Indicator light Max. display pressure Symbol 10 1.0 Unit: MPa Without indicator light Nil L2 Neon light (100 VAC/220 VAC) Attachment (Cover ring assembly) L5 LED/24 VDC Connection thread Without cover ring assembly Symbol Specifications Symbol Size Nil 01 R 1 8 Clear cover has no protrusion. (Clear cover is irremovable.)

This series is available in four body sizes with piping from M5 to 3/4 in Rc, NPT or G thread types.Modular type filter regulator , Rated filtration ( m): 2, 10, 20, 40 , 70 or 100 , Optional embedded pressure gauge , Available with built-in backflow mechanism , Rc, G(PF) or NPT threads, PUSH NUT (AW20*A), AIRLINE EQUIPMENT, AW MASS PRO, C1, AW MASS PRO 1/8 PART, 0.04409 lb

This series is available in four body sizes with piping from M5 to 3/4 in Rc, NPT or G thread types.Modular type filter regulator , Rated filtration ( m): 2, 10, 20, 40 , 70 or 100 , Optional embedded pressure gauge , Available with built-in backflow mechanism , Rc, G(PF) or NPT threads, F/R MAINTENANCE KIT, AIRLINE EQUIPMENT, AW MASS PRO, C1, AW MASS PRO 1/8 PART, .02772 lb

(Nm) L(mm) MHM-16D M3x0.5 0.63 6 MHM-25D M4x0.7 1.5 8 MHM-32D M5x0.8 3 10 MHM-50D M6x1 5.2 12 (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 -7- 2-3. 40 2-4. () 5 5 P-01-11 -8- 2-5. 1.52 2-6. 1 ()ISO VG320 (SDS) -9- 2-7. 1) 1) 2) 3) 12mm -10- 2 C3 C1 C2: C3 D-M9V D-M9WV D-M9AV D-M9 D-M9W D-M9A D-P3DWA A B E G A B E G L A B E G L D F H MHM-16D 9.1 9.1 5.6 4.6 8.1 12.8 11

Operating compressor: 0.75 kW or more, Discharged flow rate: 100 L/min (ANR) or more When using 2 or more auto drains, multiply the value above by the number of auto drains to find the capacity of the compressors you will need. For example, when using 2 auto drains, 1.5 kW (200 L/min (ANR)) of the compressor capacity is required.

|vF3l3O (B) (A) ' 0 1 c 2 Clo6td C.l49r rd d#{Ft ffi# E I S E 2 {R2XPXB1) Low power consumption -1.8WDc (F2)(P)(F1l NVF3S3O Exh.Bt C.ii.. i{VF3,(3O (B) (A) c1 c2 ryffTfl-TTrl,* Er\llt'lll/'Es) EI SE2 Pr.aqa ConL. NVF353O f l Operating prs6sur range 2 pGiEon singb 20 -129 PSI S(1.5 -gkgF) 2 pssition double-15-128 P$l (1 -gkgflcm'?)

Symbol Description C1 N.C. (Normally closed) Drain port is closed when pressure is not applied. D2 N.O. (Normally open) Drain port is open when pressure is not applied. 1 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl.

C1> The power supply of input device has a short circuit. C1> The power supply of either input device of adjoined LED has a short circuit. Red LEDs are ON Either of the following conditions: The input device ON/OFF count has exceeded the set value. The input device is open circuit. (Only for EX600-DX C1).