Do not use the product with flammable fluid Fire or an explosion may result. Only air is an applicable fluid. Do not use the product in a place where static electricity is a problem. Otherwise failure or malfunction of the system can result. If using the product in an interlocking circuit Provide a double interlocking system, for example a mechanical system.

switch (Lm) Operating angle m: The value of the individual switchs movement range Lm as represented by an angle.

plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer to page 646 for dimensions with connector cable.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.

is an inductive load. w In a case where the wiring load is greater than 5 m.

The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount the switch in a location where there is no vibration (Display: greater than 98 m/s2, Sensor: 4.9 m/s2 or less), or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

JS20, 32, 40, 63 Center of sphere M M U U D J F B E G P A R H (mm) Max. thread depth P Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) Weight (kg) M A B C D E F G H J Model JS10-4-070 JS16-5-080 8.5 0.5 17 0.01 14.4 M4 x 0.7 9.5 12 4 7 4.7 80 4 1.5 26 12 0.5 23 19 0.02 M5 x 0.8 13.5 16 6 10 5.8 210 5 2 34.5 JS20-8-125 JS32-10-125 15.5 0.5 29.9

52 46 55 63 69 S 33 36 40 46 50 52 Z 46 52 56 65 73 79 6 10 16 20 25 32 7 9 12 16 20 24 6 depth 4.8 6 depth 5 7.6 depth 6.5 9.3 depth 8 9.3 depth 9 11 depth 11.5 5 7 Free Mount Cylinder Double Acting, Single Rod Series CU Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A9 D-M9 D-F9W 22 (24.5) ( ): Denotes the values of D-A93.

(The switch will stay ON all the time.) 1) For an auto switch without a connect protection circuit, use a contact protection box when the wire length is 5 m or longer. 2) Even if an auto switch has a built-in contact protection circuit, when the wiring is more than 30 m long, it is not able to adequately absorb the rush current and its life may be reduced.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. However, please contact SMC for water-resistant products of 12 and 16. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.

and case) Withstand voltage 10 to 60C Ambient temperature Enclosure IEC60529 Standard IP67 Lead Wire Lead wire length indication (Example) D-M9BW L Lead wire length Nil M L Z 0.5 m 1 m 3 m 5 m Note 1) Lead wire length Z: 5 m Applicable auto switches Solid state auto switch: Manufactured upon receipt of order as standard.

Symbol Specifications -X12 Lubricant: Vaseline -X21 Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X214 Restrictor (Without check valve) 10Clean Series 565 A AS Series Needle Valve/Flow Rate Characteristics AS2201F-G02-m, AS2211F-G02-m AS2301F-G02-m, AS2311F-G02-m AS2201F-02-mPA, AS2211F-02-mPA AS2201F-G01-m, AS2211F-G01-m AS2301F-G01-m, AS2311F-G01-m AS2201F-01-mPA

The drawing shows with an auto switch. Eliminate the unnecessary parts.

Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].

Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude For the product operation at an altitude of 1800 meters, the cooling capacity at an altitude of 1800 meters = Cooling capacity 8.4 x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.

Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.

With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the voltage is 24 VDC. kit (Serial transmission unit) kit (Lead wire cable) The dust-protected type SI unit is applicable

Mounting orientation and static moment Mounting orientation Static load Horizontal mounting Ceiling mounting Wall mounting Vertical mounting Bore size (mm) A [mm] 6 10 15 20 25 32 40 m m x g x x m x g x y 19 21 25 27 33 40 49 m x g x x m x g x y m x g x (z + A) m x g x x m x g x (z + A) m x g x y M1 M2 M3 Static moment A: Distance between the center of the guide shaft and the upper surface