In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.
Vacuum switch Series ZS 13-1-6 Model Selection Single Unit System Equipment such as an ejector is configured as an individual unit. Thus, it is possible to create a flexible system configuration in which the circuit composition and the mounting locations can be selected as desired.
Use an auxiliary pipe or the like and apply force evenly when tightening the cap screws on the cover and case.
If an accurate stopping position is required at the stroke end or midstroke, use an external stopper to secure accurate positioning.
/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.
Note 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation. In this case, an intermediate stop can be performed only by using an external stopper, etc. Note 2) Made-to-order products should be considered, too, depending on an operating environment, etc.
J 70C Nylon tarpaulin K 110C* Neoprene cloth * Maximum ambient temperature for the rod boot only. Mounting Bracket Part No.
Cannot be used as an emergency shutdown valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutdown valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2.
When disassembling a cylinder with a bore of 20 to 40, use a vise or the like to hold the wrench flats portion of the tube cover or the rod cover on one side, while placing a wrench or an adjustable wrench on the other side to loosen and remove the cover. To replace, tighten it an additional 28 from the installed position.
Description Body class Symbol Bracket assembly LQ-GBL J K 1, 2 J type K type 1, 2, 3, 4, 5, 6 L M L type M type (for short piping) Table 1 Tubing size symbols Replacement parts Tubing O.D. Metric sizes Tubing outside diameter Part No.
An approximate plate-end deflection X without a load is shown in the graph below.
Refer to page 120 for an order example.
Port plug K Refer to page 516.
Grommet: G Conduit: C 2-M 2-M L L K Approx. 300 K Q F D Approx. 280 D Q F C R C G (PF) 1/2 R E B A H E 2-P Port size A H 2-P Port size B DIN connector: D Conduit terminal: T 2-M 2-M L L K Cable 6.8 to 10 K 27.5 F F Q (Q) 34 S 25 U R C R C G (PF) 1/2 (44) E B A H D (S) E G (PF) 1/2 B A H D 2-P Port size 2-P Port size N.C.
AW-OMX0057-A PRODUCT NAME Filter Regulator MODEL / Series / Product Number AW20(K)-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AW30(K)-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)06(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW60(K)-(F,N)06(F,N)10(B,C,
If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.
To operate the cylinder at these values, prevent dust from entering by installing an AN120-M5 silencer on the EXH port.
Cylinder suffix Built-in Magnet Cylinder Model Rod boot Nil J K Without rod boot Nylon tarpaulin Heat resistant tarpaulin Bore size 40 50 63 80 100 40 mm 50 mm 63 mm 80 mm 100 mm If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
If there is no buffer mechanism, an excessive impact force is generated. As a result, the tensile compression force of the floating joint may exceed its maximum level.