Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
A large digital display provides a clear view of the current and set values.
A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?
A large digital display provides a clear view of the current and set values.
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: -
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: -
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: -
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: -
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 3 (PF2W511: 10~100), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)