SMC Corporation of America
Elite Part Number Search
Search Results "HRL100-AN-20-D1"

When system performance declines due to filter element clogging, worn vacuum pads, piping leakage, etc., the switch can detect and indicate an oncoming problem before failure occurs.

Therefore, do not operate it in an environment that is exposed to chemicals such as thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, or water-soluble cutting oil (alkalinic). 2. Operate it away from direct sunlight.

In-line type AS1001F AS2001F AS2051F AS3001F AS4001F 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 Dual speed controller ASD230F ASD330F ASD430F ASD530F ASD530F ASD630F 6 to 20 20 to 32 20 to 40 20 to 40 40 to 63 63 to 100 M5 1/8 1/4 1/4 3/8 1/2 Applicable cylinder bore size (mm) Piping side port size Cylinder side port size Model AS1200 AS2200 AS3200 AS4200 M5 1 2 1/8 1/4 3/8 1/2 3/4 1 1

-02 KPGT06-M5 KPGT06-01 KPGT06-02 KPGT08-01 KPGT08-02 KPGT10-02 KPGT10-03 KPGT12-03 KPGT12-04 M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 8 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 6 13 19 7 14 20 14 22 29 39 41 38 17 21 25 18.5 23.5 27.5 26 30 33 34.5 37 39.5 4 4 4 D1 18 10.4 20.7 10 D1 8 A L2 6 10 10 19.5 12.8 22.8 D2 H Connection threads 10 (R) 8 26 18 15.2 21.5 26.3 12

Inch Size Model Applicable tubing O.D. d T H D1 D2 D3 L1 L2 L3 A1 A2 Max. Max. Min. Min. Max. Min.

Refer to CAT.E824A "Pressure Switch" Series ZR How to Order Ejector Systems ZR1 20 S 25 M Z 1 5 K1 D1 Ejector unit nozzle size 1.0mm 10 Digital vacuum switch specifications (D1, D2, D3) 1.3mm 13 Symbol Lead wire length 1.5mm 15 Applicable switch Output specifications 25 (L) Lead wire length 0.6 (3.0) m 1.8mm NPN output 18 D1 D2 26 (L) Lead wire length 0.6 (3.0) m Analog output 2.0mm 20 65

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 20 L/min, CH2 Optical Head

Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiation heat. 4. Do not use in environments which exceed the ambient temperature specifications of the product. Caution 1.

An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.

Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8"1/2" 2.5, 4, 6 AS121F-M3 AS131F-M3 M3 x 0.5 6, 10, 16, 20 AS121F-M5 AS131F-M5 M5 x 0.8 6, 10, 16, 20 AS121F-U10/32 AS131F-U10/32 10-32 UNF Tube swivels 360 Universal type permits 360 piping swivel. (1) 20, 25, 32 AS221F-01 AS231F-01 R 1/8 20, 25, 32,