Magnet: Built-in, Mounting: Axial Foot, Bore Size: 10mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 10mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: A--With Switch Rail, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 10mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 10mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 10mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Cushion: Air cushion, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(m): N/
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.08~0.7, Port thread type: M5 × 0.8, Auto
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product, and replaced byCDM2B40TN-60AZ
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Clean Series: Vacuum Suction Type, Magnet: Built-in, Mounting: Basic Style, Stroke: 60mm, Cushion: Air Cushion, Except Ø6, Head Cover Port: 90° to Axis, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, Lead Wire or Prewired Connector: 3m, Number: -, Bore Size: 10mm
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, Cushion: Air cushion, Specification: Built-in magnet, Auto Switches: J79C, Lead Wire Length(m): 3, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, Cushion: Air cushion, Specification: Built-in magnet, Auto Switches: J79C, Lead Wire Length(m): 3, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, Cushion: Air cushion, Specification: Built-in magnet, Auto Switches: J79C, Lead Wire Length(m): 3, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, Cushion: Air cushion, Specification: Built-in magnet, Auto Switches: J79C, Lead Wire Length(m): 3, The number of the switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CU COMPACT CYLINDER, LD, 32MM CU DOUBLE-ACTING, 1.45791 lb
The series CU free mount cylinder saves space and allows direct and precise mounting. It is available in 6mm to 32mm bore sizes with stroke lengths up to 50mm. Options include auto-switch capabilities, free mount choices, recessed switch mounting grooves, non-rotating rod, double rod, single and double acting, and rubber bumpers standard. Bore sizes from 6mm to 32mm available, Stroke lengths