AFJ40-04-80-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 80 m Large flow type Nominal filtration rating: 80 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min(ANR)] 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min (ANR)] 783 AFJ20 to AFJ40 Series Construction AFJ20 AFJ30, AFJ40 OUT IN OUT IN q q r r w w (y) e (y) t e t Component Parts No.
D-sub Connector. Series SV D-sub Connector. How to Order . Manifold Electrical Wiring. Dimensions . Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV3000 for D-sub Connector. Series SV4000 for D-sub Connector. Flat Ribbon Cable Connector . Series SV Flat Ribbon Cable Connector.
F Inlet air pressure 102psi (0.7 MPa) D F Inlet air pressure 145psi (1 MPa) Outlet air set temperature 86F (30C) Outlet air set temperature 68F (20C) E Air flow 24.7 scfm (700 L/min [ANR]) E Air flow 2.8 scfm (80 L/min [ANR]) IDH6 is selected from Data .
P When mounted on the manifold, the common exhaust discharges the pilot and main valve exhaust through a common exhaust port to enable simple exhausting. 700 B 600 Max.operating speed (mm/s) Piping length1m JIS Symbol B A 500 Piping length5m A D SY (Single) 400 R P SYJ C 300 SX How to order valve with built-in speed controller SYJ5l 5l--lll l--l 200 VK Port size VZ 100 Config.
Prefix it to the part nos. of the solenoid valve, etc. 5-4-6 3 Port Air Operated Valve Series SYJA500/700 Specifications Fluid Operating pressure range (MPa) Pilot pressure range (MPa) Note 1) Air 0.15 to 0.7 (0.4 x P + 0.1) to 0.7 P: Operating pressure range Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note 2) 10 to 50 (No freezing
WO Edition D Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
To find the stroke time (t), follow arrow from your stroke length ("L") to the solid line representing the load ratio (d%) for the application then up to the stroke time (t). To find the ending cylinder speed (u), follow arrow from your stroke length ("L") to the dotted line representing the load ratio (d%) then down to the ending cylinder speed (u).
YX Edition B Edition D The HRR010 (air-cooled type, water-cooled type) has been added. Number of pages has been increased from 36 to 44. YV Edition C Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
Data A Volume of cylinder/Capacity of converter 180 160 140 125 100 300 250 800 700 600 How to Select 200 10,000 8,000 6,000 5,000 4,000 3,000 500 400 qSelect the bore size of air-hydro cylinder 80 First of all, select a bore size from data
*Refer to the table of Applicable stroke 6mm 6mm 8mm 8mm 10mm 10mm B B Cable type *Applicable stroke Standard produced upon receipt of order Without cable Nil Without cable Nil 100 100 200 200 300 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 Robotic type cable R Robotic type cable R 11-LEFS25 11-LEFS25 Standard cable S Standard cable S 11-LEFS32 11-LEFS32 Motor cable
BBA1: D-A5/A6/F5/J5 types *"D-F5BAL" switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, "BBA1" screws are attached.
BBA1: D-A5/A6/F5/J5 types *"D-F5BAL" switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, "BBA1" screws are attached.
Reduced outgassing o u Resin materials eliminated Laser marking is employed for the model designation. d t g e a c 2 s u s d i e Reduction of outgassing due to surface treatment n o u d t R g g e a c 1 s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.
30 37 47.3 d M6 x 1.0 M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 Part no.
t o o g e a n L c 2 s u s d Particulate generation has been reduced at the stroke ends by reducing impact using a sine cushion and by stopping the stroke using an internal stopper. i e Reduction of outgassing due to surface treatment n Impact acceleration [m/s2] o u d t R g g e a c 1 s u s d 5 i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless
Auto Switch Mounting Height (mm) Auto switch model D-A9 D-M9 D-M9W D-M9A D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G59F D-F5 D-J59 D-F5W D-J59W D-F59F D-F5NT Note 2) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-A3C D-G39C D-K39C D-A44C D-Y69 D-Y7PV D-Y7WV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A9V D-M9V D-M9WV D-M9AV Note 2) D-P4DW D-P3DW Hs Ht Hs Ht Hs Hw Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Hs
Auto Switch Mounting Height (mm) D-B5m D-B64 D-B59W D-G5m D-K59 D-G5NT D-G5mW D-K59W D-G5BA D-G59F Auto switch model D-F5m D-J59 D-F5mW D-J59W D-F5BA D-F59F D-F5NT D-Z7m D-Z80 D-Y59m D-Y7P D-Y7BA D-Y7mW D-M9m D-M9mW D-M9mA D-A9m D-A3mC D-G39C D-K39C D-A44C D-A3m D-G39 D-K39 D-A44 D-A5m D-A6m D-A59W D-M9mV D-M9mWV D-M9mAV D-A9mV D-Y69m D-Y7PV D-Y7mWV D-P3DWA D-P4DW Bore size Hs Ht Hs Ht Hs
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
position U U side D D side Stations SS5Y3-45FD-05U-C6-Q .1 set (Type 45F, D-sub connector 5 station manifold base part no.)