, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Band mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
Wire Length(m): 0.5, The number of the switches: 1, Type of Auto Switch Mounting: Band mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
Wire Length(m): 3, The number of the switches: 1, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
voltage Indicator light Electrical entry direction Wiring (output) Special function Pre-wired connector Applicable load None (N) Type 3 (L) 5 (Z) DC AC Perpendicular In-line Perpendicular In-line 3-wire (NPN equiv.) 5 V A96 A96V A76H IC circuit Reed switch Grommet 200 V A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A93 M9N
Magnet: D (Built-in Magnet), Mounting: B (Basic), Shaft: W (Double), Size: 40, Rotating Angle: 90 (Single/Double Vane), Vane Type: D (Double), Connecting Port: Non (Side Ported), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry_Lead Wire: L (3m)
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Indicator light Wiring (Output) Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V
Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 15 mm, Rotating Angle: 90 (90°), Vane Type: D (Double Vane), Connecting Port Location: Side Ported, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m)
Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 20 mm, Rotating Angle: 90 (90°), Vane Type: D (Double Vane), Connecting Port Location: Side Ported, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: MDPC (1.0m Cord Length, M12-4 Pin Connector)
Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 10 mm, Rotating Angle: 90 (90°), Vane Type: D (Double Vane), Connecting Port Location: Side Ported, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m)
Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 40 mm, Rotating Angle: 90 (90°), Vane Type: S (Single Vane), Connecting Port Location: Side Ported, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m)
Magnet: D (Built-in Magnet), Size: 20, Rotating Angle: 90 (90°), Vane Type: D (Double Vane), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m)
strength (cm) Pressure Symbol and sketch (MPa) Symbol of bracket Rod side Frang e F Head side flange 103 92 113 Foot: 79 70 86 L G 66 58 72 45 38 47 33 27 34 26 22 27 96 83 106 Center Clevis trunnion 71 61 76 CD T 59 50 62 135 119 147 101 89 111 84 74 91 Rod side Frang e F Head side flange 301 267 330 Foot: 231 207 253 L G 193 172 212 144 126 156 109 94 118 90
Lead wire length (m) Auto switch model MHC Electrical entry direction Load voltage Pre-wired connector Applicable load 5 (Z) Type Electrical entry Special function Indicator light Wiring (Output) 0.5 (Nil) 1 (M) 3 (L) DC AC Perpendicular In-line MHT M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire(NPN) IC circuit 5 V, 12 V 12 V 3-wire(PNP) Solid state auto switch MHY
Smooth Cylinder Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure 0.04 Minimum operating pressure MPa 12 16 0.03 20 25 32 40 0.02 50 63 80 100 0.01 0 0 10 20 30 40 60 50 70 80 90 100 Bore size mm (Measurement based on JIS B8377) Series CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 Stable operation possible even at a
, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: APC, Pivot Bracket: Shipped together, Rod End Bracket: Single knuckle joint, Type of Mount Support: Integrated clevis type (90°), Rod Tip Shape: Male thread, Rod Boot: None, Custom-made Specifications: None, Type: Pneumatic type
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9N, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9N, Lead Wire