Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 325, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 615, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 725, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 750, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

AFJ40-04-80-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 80 m Large flow type Nominal filtration rating: 80 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min(ANR)] 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min (ANR)] 783 AFJ20 to AFJ40 Series Construction AFJ20 AFJ30, AFJ40 OUT IN OUT IN q q r r w w (y) e (y) t e t Component Parts No.

D-sub Connector. Series SV D-sub Connector. How to Order . Manifold Electrical Wiring. Dimensions . Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV3000 for D-sub Connector. Series SV4000 for D-sub Connector. Flat Ribbon Cable Connector . Series SV Flat Ribbon Cable Connector.

F Inlet air pressure 102psi (0.7 MPa) D F Inlet air pressure 145psi (1 MPa) Outlet air set temperature 86F (30C) Outlet air set temperature 68F (20C) E Air flow 24.7 scfm (700 L/min [ANR]) E Air flow 2.8 scfm (80 L/min [ANR]) IDH6 is selected from Data .

P When mounted on the manifold, the common exhaust discharges the pilot and main valve exhaust through a common exhaust port to enable simple exhausting. 700 B 600 Max.operating speed (mm/s) Piping length1m JIS Symbol B A 500 Piping length5m A D SY (Single) 400 R P SYJ C 300 SX How to order valve with built-in speed controller SYJ5l 5l--lll l--l 200 VK Port size VZ 100 Config.

Prefix it to the part nos. of the solenoid valve, etc. 5-4-6 3 Port Air Operated Valve Series SYJA500/700 Specifications Fluid Operating pressure range (MPa) Pilot pressure range (MPa) Note 1) Air 0.15 to 0.7 (0.4 x P + 0.1) to 0.7 P: Operating pressure range Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note 2) 10 to 50 (No freezing

WO Edition D Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.

, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.

To find the stroke time (t), follow arrow from your stroke length ("L") to the solid line representing the load ratio (d%) for the application then up to the stroke time (t). To find the ending cylinder speed (u), follow arrow from your stroke length ("L") to the dotted line representing the load ratio (d%) then down to the ending cylinder speed (u).

YX Edition B Edition D The HRR010 (air-cooled type, water-cooled type) has been added. Number of pages has been increased from 36 to 44. YV Edition C Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.