SMC Corporation of America
Elite Part Number Search
Search Results "CDLSD160TN-1200-M9PSDPC"

(mm) Maximum stroke Cushion Piping directions Bore size (mm) Model Height Overall length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750 Concentrated piping on left -X 25 1200

If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range Bore

1 3/4 5 1/8 NI-1200 2 1/4 4 2 1/2 1 3/4 2 1 1/2 -12 NCA1-1400 2 5 1/8 NI-1400 3 5 2 1/2 2 2 1/2 1 7/8 -12 NCA1-1401 2.5 6.19 NI-1401 3 1/2 5 13/16 3 2 1/2 2 13/16 2 1/4-12 NCA1-1402 3 6.25 Note) Retainer Rings are included NI-1402 3 1/2 6 1/8 3 3 3 1/4 2 1/2-12 42 Medium Duty Air Cylinder Series NCA1 How to Order Auto Switches Wire Lead Type Connector Type D D PC Lead wire length 0.5 (m)

If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range

C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.

Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: TN (NPT), Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: A96--Reed, DC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: 2 pcs. (Or None in the Case of No

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: TN (NPT), Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: TN (NPT), Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: Z (5m Lead Wire), Number: 2 pcs. (Or None

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: A96--Reed, DC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 5m Lead Wire, Number: 2 pcs. (Or None in the Case of

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: A34--Reed, DC Volt >5 <24, AC Volt <200, LED, Terminal, None, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: A64--Reed, DC Volt >5<24, AC Volt <200, 0.5M, Lead Wire or Pre-wired Connector: 5m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Lock

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: A64--Reed, DC Volt >5<24, AC Volt <200, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: A64--Reed, DC Volt >5<24, AC Volt <200, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: A64--Reed, DC Volt >5<24, AC Volt <200, 0.5M, Lead Wire or Pre-wired Connector: 5m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Lock

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized