SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2D10-30Z-V-M9P-B"

U CU T1 CQS F B E CQM Joint And Mounting Bracket (Type A, Type B) Part No.

Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes

D-P4DWL D-P4DW32100 16100 5080 18-3 30% 16100 20100 5080 18-4./ 18-4/ D-A9(V)/M9(V)/ M8W(V)/M9A(V)L 16100 20100 5080 20

Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes

Applicable load Type 2-wire 3-wire Solid state auto switch Auto switch model D-M9B(V) D-M9N(V) Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 40 mA 40 mA or less Load current range Indicator light Yes Yes 24 VDC relay, PLC PLC: Programmable Logic Controller Refer to page 946 for the applicable auto switches list.

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead

Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 10mm, Stroke: 30mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead

B B For D-F8 Operating range at proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch (Lm) 11-6-10

Lead wire length (m) 0.5 (Nil) 3 (L) Load voltage Auto switch model Electrical entry direction Perpendicular In-line Indicator light Wiring (Output) Special function Type Electrical entry 5 (Z) AC DC F8N F8P F8B M9N M9P M9B F9NW F9PW F9BW 3-wire (NPN) Solid state switch 3-wire (PNP) 12 V 24 V Grommet Yes 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire Diagnosis indication (2-color) Lead

Relay, PLC Yes Grommet 24 V 3-wire (NPN) Diagnostic indication 2-color indication 5 V, 12V IC circuit 3-wire (PNP) 12 V 2-wire A96 A93 A90 A96V A93V A90V 5 V IC circuit 3-wire (NPN equivalent) Yes 100 V 12 V Grommet Relay, PLC 24 V 2-wire 5 V, 12 V IC circuit 100 V or less Solid state auto switches marked with are produced upon receipt of order.

Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 10mm, Stroke: 45mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: V (Single Knuckle Joint), Auto Switch: M9P--Solid State, Gen.

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs.

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting,

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 30mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: 2 pcs.

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead Wire