Supplied regenerative resistors or regenerative option is used with the servo amplifier of 11k to 22kW. 01: FR-BU2-(H) FR-RC-(H) FR-CV-(H) 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50(Cooling fan is required) 08: MR-RB31 09: MR-RB51(Cooling fan is required) 80: MR-RB1H-4 81: MR-RB3M-4(Cooling fan is required) 82: MR-RB3G-4(Cooling fan is required) 83: MR-RB5G-4(Cooling fan
-01-06 VZM550-01-06S Toggle lever VZM550-01-08 PAT.
-01-06 VZM450-01-06S Toggle lever VZM450-01-08 VZM450-01-30R VM-30CR Red VM-30CB Black VZM450-01-30B Push button (Mushroom) VM-30CG Green VZM450-01-30G VM-30CY Yellow VZM450-01-30Y VZM450-01-32R VM-32CR Red VM-32CB Black VZM450-01-32B Push button (Extended) VM-32CG Green VZM450-01-32G VM-32CY Yellow VZM450-01-32Y With a set of red, black, green, yellow VM-33C Push button (Flush) VZM450-01
Arrangement example: Paddle set for IF300-06-00 (Part number are not existed.)
Type Type Elbow type straight type In-line type REA25 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REA32 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REA40 AS2201F-02-06-X214 AS2301F-02-06-X214 AS2001F-06-X214 REA50 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 REA63 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Table.
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
How to Order VR 12 1 06 0 F Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 2 1/8 standard 1/4 standard 23 04 06 08 10 01 03 07 09 11 3.2 4 6 8 10 1/8" 5/32" 1/4" 5/16" 3/8" With One-touch fitting Use 1/8" tubing for 3.2. 1 Series VR120F Application Circuit Examples Self holding circuit 1. When "A" is turned ON, output goes ON. 2.
Conditions Body ported Tube bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 Series MB 6 x 1 m AS2301F-06 AN110-01 VZ5120-01 3-3-55 Series VZ5000 Construction 2 position single 2 position double De-energized De-energized 3 position closed center/exhaust center/pressure center 3 position closed center De-energized De-energized 3
0ol2,oV fiHz 11 = ilSOV 60Hz 49 = 12 VAC 50Hz 51 = 12 Y96 52 = 24 VDC 53 = ,r8 VDC Portlng m = Valve Only w/casket Set) NVS S24 01 = Mounted on Indivldual Subplate l/4'NPTF Slde Ports (5) 02 = Mounted on Indivldual Subplate 3/8' Hetf diae eorts 1q 03 = Mounted on Individual Subplate l/4" NFrF Bottom Ports (5) 06= Mounted on Indlvldual Subplale 1i4" NPTF Bottom Ports (5) & Side Ports (1) 21
Note) When ordering ejector without valve, select Nil for mounting. 04 KJH C2 Port size 04 06 03 07 !
AF10 AF20 AF30 AF40 AF40-06 AF50 AF60 No.
Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Symbol 01 02 01 02 02 03 03 04 04 06 10 Body class LQ3 Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.
Refer to Specific Product Precautions on page 1006. 990 E-P HYREG VY1 Series R Standard Specifications 0 1 0 1 0 1 VY110 01 02 0 1 0 1 VY140 0 1 VY150 0 1 VY170 0 1 20 VY190 0 1 VY1D00 M5 VY1A0 VY1B0 M5 VY120 01 02 VY130 02 03 Model 10 12 10 04 02 03 04 04 06 14 M5 01 Port 1(P) 11 2 Port size 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 1 M5 M5 2 2 M5 2(A) 1 4 3(R) Weight
ASS AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 ASR ASQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG
Port size N M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 Needle Valve/Flow Characteristics AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) Effective
AK AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 VCHC Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa ASR ASQ 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG
Interface Speed Controls Cylinder speed can be controlled by throttling exhaust air. 20 Comforming to ISO 15407-2 Series VSR/VSS8-4 How to Order Manifold (ISO15407-2) 03 SDQ VV8 01 N 1 1 N 5 W1 Option Note 1) Size Nil None 01 Size 01 Special wiring specifications (Except double wiring) K Number of stations External pilot R 1 1 station Direct exhaust with built in silencer S 16 16 stations
actuation VFN VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 Bore size Series CA1 Pressure 0.5 MPa Load factor 50% Stroke 400 mm Average speed (mm/s) Series 100 40 50 63 80 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 800 700 600 500 400 300 200
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Clip Circuit with light PR plate qChanging the piping direction from in-line to perpendicular (port on the valve) is possible on the VQZ100 series. Follow the steps below to change piping direction: Remove the fitting clips that hold the fitting and port plug in place.
Setting range: MT.01 to MT.05 (Initial value: MT.01) Contact output signal 3 Select function 16. Press the [] key.