Voltage symbol 24 VDC V100-61-3-05 DC 24 VZ 12 VDC V100-61-3-06 DC 12 VZ 100 VAC V100-61-2-01 100/110 VZ 200 VAC V100-61-2-02 200/220 VZ 110 VAC V100-61-2-01 100/110 VZ 220 VAC V100-61-2-02 200/220 VZ 240 VAC V100-61-2-07 240 VZ If an AC specification without DIN Terminal (DO) is selected, always use a DIN connector with surge voltage suppressor as the connector.
How to Order Hexagon Socket Head Cap Screw ZQSTB 05 Fitting assembly Number of stations Clip (ZK1-CP-A) 10 pcs. in one set 01 02 1 station 2 stations Applicable tubing O.D.
Rating symbol DC 24 VS V100-61-5-05 24 VDC DC 12 VS V100-61-5-06 12 VDC 100/110 VS V100-61-4-01 100 VAC 200/220 VS V100-61-4-02 200 VAC 100/110 VS V100-61-4-01 110 VAC 200/220 VS V100-61-4-02 220 VAC 240 VS V100-61-4-07 240 VAC With Light/Surge Voltage Suppressor Rated voltage Part no.
(Default) Spare Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 3 36 4. STARTUP 4.
-33S KV2Y03-34S KV2Y03-35S KV2Y07-11-35S KV2Y07-34S KV2Y07-35S KV2Y07-36S KV2Y11-07-35S KV2Y11-07-36S KV2Y11-35S KV2Y11-36S KV2Y11-37S KV2Y13-07-37S KV2Y13-11-36S KV2Y13-11-37S KV2Y13-35S KV2Y13-36S KV2Y13-37S KV2Y15-37S 14.29 14.29 14.29 14.29 19.00 14.29 14.29 17.46 19.00 19.00 19.00 19.00 22.23 23.80 23.80 22.23 19.00 19.00 22.23 23.80 13.2 13.2 13.2 13.2 17.9 13.2 13.2 13.2 17.9 17.9
ALARM01 Water Leak Detect FLT 01 ALARM03 RFGT High Press FLT 03 ALARM04 CPRSR Overheat FLT 04 ALARM05 Reservoir Low Level FLT 05 ALARM06 Reservoir Low Level WRN 06 ALARM07 Reservoir High Level WRN 07 ALARM08 Temp. Fuse Cutout FLT 08 ALARM09 Reservoir High Temp. FLT 09 ALARM10 Return High TempWRN 10 ALARM11 Reservoir High Temp.
Alarm1 Water Leak Detect FLT 01 Alarm2 Incorrect Phase Error FLT 02 Alarm3 RFGT High Press FLT 03 Alarm4 CPRSR Overheat FLT 04 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10*1 10 Alarm11 Reservoir High Temp.
Alarm1 Water Leak Detect FLT 01 Alarm2 Incorrect Phase Error FLT 02 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10 Return High Temp WRN 10 Alarm11 Reservoir High Temp.
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 Flow
ZQ-OM01301-A 1.How to Order Vacuum Ejector System (without energy saving function) Model of a single unit ZQ 05 1U A-K15L B-EA M G -3 3-N (1) (2) (3) (4)(5) (6) (7) (8)(9)(10)(11)(12) (7) Vacuum pressure switch unit specifications NilNote 3) With unit selection function (1) Nozzle nominal size M Fixed SI unit (kPa) 05 0.5 P Note 3) With unit selection function 07 0.7 (Initial value psi) 10
ZQ 05 1U A-K15L B-EA M G -3 3-N (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)(11)(12) (1) (7) 05 0.5 5) 07 0.7 M SI (kPa) 10 1.0 5) (:psi) P 5) (99 10 ) (2) (8) 1U 3M G (2m) (9) (10) (V ) 6) (3) 0 (M5x0.8) 7) K1 N.C. N.C. K 1 3.2 () K2 N.O. N.C. 6) 2 4 () J1 N.C. 3 6 () J2 N.O. 4 3.2 () 1) ()(N.C.)
(Example) VV5Z3-43P-07-C41 pc. (Manifold base) VZ3143-5MOZ 3 pcs. (Valve) VZ3243-5MOZ 3 pcs. (Valve) DXT192-13-3A1 pc. (Blanking plate assembly) DXT192-52-1-4A3 pcs. (Connector assembly) DXT192-52-2-4A3 pcs. (Connector assembly) The asterisk denotes the symbol for assembly.
LVD LVQ How to Order Manifold Base LQ1 LLH 2 A 05 11 S LVN Body class TL/TIL Tubing size for port P and L side connection Tubing size for port P and R side connection Body class 2 3 4 Symbol 2 3 4 Body class 2 to 4 Symbol 00 06 07 08 10 11 10 11 12 13 12 13 19 Tubing size Plug Symbol 00 06 07 08 10 11 10 11 12 13 12 13 19 Body class 2 to 4 Tubing size Plug LQ3 6 1/4" 6 1/4" Base type 2 8
L plug connector Closed center: VFR2310-LExhaust center: VFR2410-LPressure center: VFR2510-LM plug connector Closed center: VFR2310-MExhaust center: VFR2410-MPressure center: VFR2510-MDIN terminal Closed center: VFR2310Exhaust center: VFR2410Pressure center: VFR251001 02 01 02 01 02 01 02 01 02 01 02 01 02 D Y 01 02 D Y 01 02 D Y Applicable cable O.D. 6 to 8 [4.5 to 7] Light/Surge voltage
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
Sufx for actuator1 Inch size Metric size S Hard steel roller R Red Color of push button, selector B Black G Green Y Yellow 23 3.2 04 4 06 6 01 1/8" 03 5/32" 07 1/4" For selecting applicable tubing O.D., refer to the Model on page 2. Metric size and inch size types can be visually identied by color of the release button.
Mounting Screw Tightening Torques M3: 0.8 Nm 4-6-34 35 3 Port Solenoid Valve Rubber Seal, Body Ported/Base Mounted Series VZ500 Manifold for Internal Pilot How to Order Applicable solenoid valve VZ512--01 VZ512M--01 VZ522--01 Z522M--01 Applicable blanking plate assembly DXT201-15-4A Type 20/21 VV3Z5 20 05 1 A port A port P/R port thread type Manifold P port Stations 20 21 Type 20 Type 21
, N9 P R2 R1 28.3 1.6 18 27.2 1.6 (PE port) 1/8 (P, R1, R2 port) B A 17 One-touch fitting (A, B port) (4.9) 36 Applicable tubing O.D.: 6, 1/4" : 8, 5/16" (3.6) L plug connector (L): SYJ7120-L-01 (-F) M plug connector (M): SYJ7120-M-01 (-F) M8 connector (W0): SYJ7120-W0-01 (-F) DIN terminal (D): SYJ7120-D-01 (-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 65 31.5 [38.5]