SMC Corporation of America
Elite Part Number Search
Search Results "AL30-03-36-A"

Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.

Brown 2 A B-1 Red 1 A A-1 Cable length (L) Orange 6 B B-2 Yellow 5 B A-2 8m *1 8 Green 3 COM-A/COM B-3 10m *1 A Blue 4 COM-B/ A-3 Shield 15m *1 B Cable color Terminal no. Vcc B-4 Brown 12 *1) produced upon receipt of order. 20m *1 C GND A-4 Black 13 A B-5 Red 7 A A-5 Black 6 B B-6 Orange 9 Only Robotic type cable can be B A-6 Black 8 3 selected.

Seal guide B Slide plate Spacer Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !

CE-compliant Valve mounting direction Stations R port Nil Pilot valve is opposite the A port side. 02 2 stations A A M5 x 0.8 Nil R port P R Q CE-compliant : : A A M5 x 0.8 A port M3 x 0.5 P port M5 x 0.8 Pilot valve is on the A port side. 20 S 20 stations P port M5 x 0.8 A port M3 x 0.5 Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of

When a 3 port valve is mounted on a 5 port manifold, The "A" port is the working port. The "B"port can either be plugged or unplugged.

OUT2 NC Sensor 8 Load 41.8 4 40.3 OUT1 40 4.3 Black Main circuit 7 3 Load Brown 6 2 + SMC FLOW SWITCH Blue 5 1 35.8 36 12 to 24 VDC Series PF2W5 A 40 UNIT RESET PF2W30-A SET Panel fitting dimension 3 x 7.2 (= 21.6) 8-M3 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black 1 2 3 4 Main circuit 7 3 Load +0.5 0 Brown 19.4 6 2 + Blue 5 1 12 to 24 VDC 5 6 7 8 Series PF2W5 PF2W31-A View A The applicable

B A D-A5m/A6m D-A59W D-A44 Hs Auto switch Hs Auto switch Ht Ht B A B A Double Acting, Single Rod Double Acting, Double Rod D-F5m/J5m D-F5mW/J59W/F5BA D-F59F/F5NT Hs Auto switch Ht B A D-P3DWA Hs Auto switch Ht A B D-P4DW Hs Auto switch Ht B A 36 C96N Series Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height [mm] Auto Switch Proper Mounting Position

Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.

Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.

(A) 2 1 (P) 3 (R) Rubber seal type VQZ200 300 / Metal seal type 3 2 1 3 2 1 N.C. N.C. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) 3 2 1 3 2 1 N.O. (A) 2 N.O. (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Parts list No.

Never mount a switch in a place that will be used as a scaffold during piping work. Damage may occur if subjected to an excessive load. Especially when the switch supports piping, do not apply a load of 15Nm or more to the metal part of the switch. 11. Provide a section of straight pipe of at least 8 times the pipe diameter in the piping before and after a switch.

B C D E F G H P U Load (kn) Weight (g) M A MB JA30-10-125 JA40-12-125 JA50-16-150 JAH50-20-150 JA125-27-200 JA160-36-200 2.5 4.4 11 18 28 71 M10 X 1.25 M12 X 1.25 M16 X 1.5 M20 X 1.5 M27 X 2 M36 X 2 49.5 60 71.5 101 123 178 19.5 20 22 28 34 51 22 24 25 30 38 55 24 31 41 59,5 66 96 5 6 7.5 11.5 13 16 8 11 14 24 27 36 8 11 13.5 16 20 24 17 22 27 32 41 55 9 13 15 18 24 42 0.5 0.75 1.0 2.0 2.0

54.3 12 17 21.7 21.7 Screw-in connection S type: White color L type: Black color (Mounting hole) B C D E F G H Model A 3 8 Rc3 8 Rc3 8 Rc3 8 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL-03-04-04 Rc 133 52.45 42 19 3.5 19 20.95 20.95 133 52.45 42 19 3.5 19 151.1 60.95 47.7 19 3.5 24 26.75 151.1 60.95 47.7 19 3.5 24 26.75 I J K L M N O Model 3 8 Rc3 8 Rc3 8 Rc1 2 Rc1 2 ZH18DS-03-

Description POM Valve 19033 19014 19024 e Stainless steel Spring 19037 19015 19025 r NBR O-ring 20 x 17 x 1.5 t NBR Ring 19016 19026 y Brass, NBR Seat ring 19013 19023 u Dimensions Model Port size L1 H B AK2000-01/02 22 25 1/8, 1/4 50 AK4000-02/03/04 36 36 1/4, 3/8, 1/2 67 AK6000-06/10 50 50 3/4, 1 95 Caution Be sure to read before handling.

-02 KPGL08-01 KPGL08-02 KPGL10-02 KPGL10-03 KPGL12-03 KPGL12-04 KPQL04-M5 KPQL04-01 KPQL04-02 KPQL06-M5 KPQL06-01 KPQL06-02 KPQL08-01 KPQL08-02 KPQL10-02 KPQL10-03 KPQL12-03 KPQL12-04 17 21 25 18.5 23.5 27.5 26 30 33 34.5 37 39.5 8 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 8 10 14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 4 4 18 10.4 20.7 D1 10 L2 A D2 8 H 6 10 10 19.5

5 15-9-59 4 Series AS-FM Dimensions: Elbow Type M5 type U10/32 type Applicable tubing O.D. d Applicable tubing O.D. d H H (Hexagon width across flats) (Hexagon width across flats) A L4 A D1 L4 D1 L3 L3 M1 M1 T D2 L1 D2 L1 T L2 L2 Metric Size A L4 Weight (g) d T Model M1 D2 L2 L3 D1 L1 H Min. Min. Max. Max.

Single vane type Double vane type 90, 100 270 180 90 Chamfer 0 5 +4 0 o n ti o n ti a a 0 r r t t 9 a a o o n n R R e +4 0 g g g 0 e e n 0 a 2 1 0 1 r 7 8 9 n 0 0 e o e g ti +4 0 +4 0 g n a n a t a o r r R n n o o ti ti a a t o t o R R Chamfer A port B port Chamfer Chamfer B port A port A port B port A port B port For size 40 actuators, a parallel keyway will be used instead

141.1 99.2 99.2 19 42.9 (Lead wire length) 19 42.9 Polarity indication 13.6 13.6 A B A B B A A COM B + A B A B A B A Manual override (Push and turn for locking type) 42 31.4 Manual override (Press and turn for the locking type) 42 31.4 84.9 B: Green A: Orange 2-4.2 84.9 B: Green A: Orange 2-4.2 2-One-touch fittings (Mounting holes for manifold) (A, B port) (A, B port) 2-One-touch fittings

-A B310L B410L Y30 Y40 189 Y30L Y40L 133 Y40T For ITV10, use a modular adapter (Refer to page 585 for details). eL-bracket Accessories (Option)/Part No. 178 [Bracket] qAF30-A wAFM30-A Part No.