SMC Corporation of America
Elite Part Number Search
Search Results "56-PA5210-06"

Refer to the operation manual for the equipment used. -56- 8. Home position return (PLC) Home position returning in this operation manual is based on the MITSUBISHI ELECTRIC QD75MH positioning unit,. The original position returning parameter cannot be set at driver side.

Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included

A( ) A 24V 12V 100V SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 24V DC 12V DC 100V AC SOL SOL C(+) C ZNR Light DIN connector circuit with light AC circuit DC circuit 1 2 1 2 NL R R LED NL: Neon light R: Resistor LED: Emitting diode R: Resistor 4.3-2 Series VQ20/30 Manifold Caution Caution Valve Mounting How to Mount/Remove from DIN Rail After confirming the gasket is correctly placed under

Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting

VH410-02 to 06 3 (Closed center) 1 (P) 3 (R) Rc 1/4: 45 4 3 VH401-02 to 06 VH411-02 to 06 3 (Exhaust center) Rc 3/8: 49 Rc 1/2: 55 VH402-02 to 06 VH412-02 to 06 2 (Position) 1/4 to 3/4 2 1 1.28 VH4 Handle Operation Angle and Air Flow Direction VH420-02 to 06 VH430-02 to 06 3 (Closed center) (Refer to the figures of piping direction to the right.)

VH410-02 to 06 Rc1/4: 45(2.5) 4 3 3 (Exhaust center) VH401-02 to 06 VH411-02 to 06 Rc3/8: 49(2.7) Rc1/2: 55(3.1) 2 (Position) VH402-02 to 06 VH412-02 to 06 2 1 1.28 VH4 Handle operation angle and air flow direction 1/4 to 3/4 3 (Closed center) VH420-02 to 06 VH430-02 to 06 (Refer to figures of porting direction in the right.) 3 (Exhaust center) VH421-02 to 06 VH431-02 to 06 Rc3/4: 58(3.2

Model Description AL1000 AL2000 AL3000 AL4000 AL4000-06 AL5000 AL6000 B240A B340A B440A B540A B640A B640A Bracket assembly (1) Note 1) With bracket mounting screw (2 pcs.)

Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).

Clean One-touch fitting (for blow off) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Clean One-touch fitting (for blow off) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Clean One-touch fitting (for blowing) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 Thread connection Tubing (rod) connection R 1/8 R 1/4 R 3/8 R 1/2 Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Clean One-touch fitting (for blowing) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Blanking plug KQ2P23 04 06 Dimensions It is inserted into an unused cylinder port and SUP/EXH ports. Purchasing order is available in units of 10 pieces.

Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.

-196H-V 06 to 08 AL-197H-V 10 to 12 FKM-70 or EPDM-70 AL-198H-V Phosphoric ester 16 AL-199H-V 20 to 24 AL-200H-V 28 to 32 AL-201H-V Note) The material of seals (AL-196H-V to AL-201H-V) is EPDM-70.

Stainless steel and Brass available Hastelloy internals available for corrosion resistance How to Order Port Number q w e r t AK10 01 4PL 4 4 S 0 0 Delivery pressure Code Connections (Inletq, Outletw) Delivery pressure Code Delivery pressure 5 to 150 psig (0.034 to 1.0 MPa) 5 to 200 psig (0.034 to 1.4 MPa) 5 to 300 psig (0.034 to 2.1 MPa) 10 to 500 psig (0.07 to 3.4 MPa) Bonnet option 01 02 06

PA 02 200 VAC 50/60 Hz 01 100 VAC 50/60 Hz 08 48 VAC 50/60 Hz 01 02 03 04 07 08 05 06 002 Applicable valve model No. 13 24 VAC 50/60 Hz VXZ22 VXZ23 03 110 VAC 50/60 Hz 23 440 VAC 50/60 Hz PAX 003 AC 04 220 VAC 50/60 Hz 51 6 VDC Coil combination code 05 24 VDC 53 48 VDC PB 06 12 VDC 55 100 VDC 56 110 VDC (Refer to the table below.) 07 240 VAC 50/60 Hz DC Note) The voltage codes

Model AMR3000 AMR4000 AMR5000 AMR6000 Model name 1 4 3 8 1 2 : E4-02 : E4-03 : E4-04 1 4 1 2 : E6-06 : E6-10 3 4 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (7) 3 8 3 4 1 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float type auto drain (AMR 100) (8) IS10-01 (0.4 MPa setting) Compact pressure switch 135510 135613 Elbow (R x Rc) (9) Note 5) in the gauge part number (e.g.

Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 AS2301F-06 AN110-01 Series MB/CA2 Series CJ2 Series CM2 Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AN200-02 AN3301F-06 AS1301F-06 6 x 1 m AS3001F-06 SYJ7120-01

L-04 L-06 N-04 N-06 LL-04 LL-06 S-04 S-06 4 6 L-08 8 L-10 10 L-12 12 4 6 N-08 8 N-10 10 N-12 12 4 6 LL-08 8 LL-10 10 LL-12 12 4 6 S-08 8 S-10 10 S-12 12 0.7 1.1 1.4 1.7 2.0 Precautions Be sure to read before handling. Refer to Air Fittings & Tubing Precautions for other details. Installation Caution Cut the tube to the required length.