4 128 59 53 74 53 Width across flats 36 52 AV5000-m06, 10-5 to 6G(Z)m-A Model [mm] Optional specifications With bracket With built-in silencer Model K L M N P Q R S T U V W X Y AV2000-m02-1 to 4G(Z)m-A 30 50 51.5 44 5.5 10 66 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 14 AV2000-m02-5 to 6G(Z)m-A AV3000-m03-1 to 4G(Z)m-A 41 50 53.5 46 5.5 15 70 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width
= St/To = 1000 mm/s Maximum speed Vmax = 1.5 Vm = 1500 mm/s RHC20 7J RHC MK(2) 100 Model selection by graph RS Q G 50 Load weight M = 1000 N Max. speed Vmax = 1500 mm/s RS H A Graph 1-1 RZQ 10 RHC80 MI W S 50 100 500 1000 2000 3000 Maximum speed Vmax (mm/s) CEP1 Graph (1)-2 Vertical Drive Supply Pressure 0.5 MPa Selection Example: 2 CE1 10 Operating conditions CE2 Vertical drive Graph (
size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Read the operation manual completely before operation, and keep this manual where it can be referred to as necessary. 14) In locations where strong impacts or vibrations occur 15)
VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil assembly with terminal part no. Coil no.
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30L IDG50L 0 m 40 1 m 39 3 m 38 5 m Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. 14-19-25 22 Series IDG Single Unit/Standard Dew Point 60C Specifications How to Order 03 B IDG 60 S Option Flow rate by size None (Standard) With
Symbol Description Nil None S Lead wire with M12 connector (Straight, 5 m) L Lead wire with M12 connector (Right-angled, 5 m) Unit specification Symbol Description Nil Unit selection function*1 M SI unit only*2 *1 Under the New Measurement Act, switches with the unit selection function are not permitted for use in Japan. *2 Fixed unit: MPa, kPa Options/Part Nos.
Inlet pressure 0.5 MPa Total stroke time (t) (1) Piping length SV1000: 1 m, SV2000/3000: 2 m, SV4000: 3 m Stroke (L) Speed d% d% Stroke (mm) Speed at the end Cylinder direction Vertical upward Stroke Speed controller Meter-out, Directly connected to cylinder, Needle fully open (2) Load ratio {(Load weight x 9.8) Theoretical output} x 100% Speed at the end (u) Time (s) SOL: ON(OFF) 1-2-6
Power dissipation (W): For AC , W=V/A cos. For DC, W=V/A (Note) cos (Note) cos shows power factor. w Surge voltage The surge voltage is a high voltage generated momentarily when cutting the power supply. e Hum sound The hum sound is a noise generated through repeated adsorption and releasing on an armature adsorption surface.
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
S = 6mm 5. S = 15mm 4. S = 10mm 7. S = 27mm 5. S = 15mm 7. S = 27mm 10. S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1.
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked "" are produced upon receipt of order.
Connections 1/4 NPT (S, C1, C2), converts also ND91_ connections to1/4 NPT. RC03 H127093 Cable assembly remote mount sensor cable 30 m, angle connector D3 D3B As D3 but two pressure gauges with connections 1/4 NPT (S, C2).
HRS040--20-T/MT Note1) Applicable model Rated flow50/60HzNote 2) 3) 23(0.18MPa)/28(0.23MPa) Maximum flow rate (50/60 Hz) L/min 30/35 Pump Maximum pump head (50/60 Hz) m 50 Output W 550 Recommended earth leakage breaker capacity A 20 Cooling capacity Note 4) W The cooling capacity reduces about 300 W from the value in the catalog.
M Replacement of filter element M Replacement of filter case M Replacement of sound absorbing material 2 steps 2 steps 3 steps e q q q w w w Filter case Filter element Silencer cover Sound absorbing material Transparent filter case allows visual check of the contamination. If there is dirt inside the case, it is possible to remove the case and clean it.
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R005 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
(Applicable to all models) (Ex.)A731 D-A731 Ac ces s sorie sl Part s Li st 056 (e^6) 075 (3/4) 106 0n/16) 150 (1-1/2') 2OO (2') 25O (2-1t2',) 300 (3') 400 (4"' Jam Nd JM.O1 JM-02 JM-03 JM.O4 JM.O5 JM-05 JM-08 JM-10 Single Rod Clevis RCS-015 BCS-02 RCS-03 RCS-04 HCS-o5 RCS-05 RCS-08 RCS-10 Double Rod Clevis RDS-o15 RDS-02 RDS-03 RDS-04 RDS-05 RDS{5 RDS.08 RDS-10 w/ dn(l). rcteinino rin6{21
Bore size (mm) Bore size (mm) AS2000-01/02 AS600-10 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) No load No load No load No load Load ratio Load ratio Bore size (mm) Bore size (mm) AS4000-02/03/04 AS3000-02/03 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Circuit diagram No load No load No load No load Load ratio
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-O021 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.