70 40 160 37 M8 165 85 12 9 125 110 176 160 16 18 107 50 75 150 115 82.5 45 194 42 M10 200 95 12 11 135 115 210 190 19 23 142 Bore size (mm) W WH W V U T S Z R Y Q X O P 20 25 32 40 50 30 23 36 40 86 12 26 140 12 80 21 30 M6 x 1 M5 x 0.8 30 25 44 47 98 13 31 153 12 80 21 37 M6 x 1 M5 x 0.8 25 28.5 50 53 112 16 38 161 12 82 21 37 M6 x 1 Rc 1/8 20 33 60 63 132 20 47 188 12 92 25 44 M8 x 1.25
Standard Strokes Bore size (mm) Standard stroke (mm) 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 12, 16 20, 25 32 to 100 Manufacture of Intermediate Strokes Spacer installation Spacers are installed in the standard stroke cylinder. 12 to 32: Available by the 1
Heater assembly quantity 200/40 200/50 400/100 600/150 800/220 1200/350 100V H4 100C Heater assembly quantity used Heater power W (Nominal value) In-rush/Power consumption (Option symbolOperating voltage) 800/40 800/50 1600/100 2400/150 3200/220 4800/350 200V 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs. 3 pcs. 4 pcs.
LEHZ 3 5mm/s LEHZ10 LEHZ16 LEHZ2025 LEHZ LEHZ 32 40 6 2(3) 6 3(4) 16 11 52 84 10 4 10 5.5 28 19.5 91 147 [N] 14 6 14 8 40 28 130 210 *LEHZ1016 30%F.S.LEHZ2025 25%F.S.LEHZ32 40 20%F.S. * (LEHZJ ) 53 No.JXC-OMU0004-A LEHF LEHF10 LEHF20 LEHF32 LEHF40 2] 2] 2] 2] [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s 0 5 100 5 100 5 100 5 100 1 10 150 10 150 10 150 10 150 2 15 200 15 200 15
Bore size (mm) Maximum stroke Standard stroke (mm) 32 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 1400 25, 50, 75, 100, 125, 150, 175
A A1 E1 L1 MM R1 U1 ND NZ L NX M22 x 1.5 38 21 21 27 M26 x 1.5 44 21 24 31 Y-G02 Y-G03 Y-G04 Y-G05 Y-G08 Y-G10 16 20 +0.4 +0.2 +0.4 +0.2 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 A knuckle pin and retaining rings are included. 34 41 42 56 71 79 8.5 25 30 30 40 50 55 M8 x 1.25 10.3 11.5 8 10 10 14 18 22 16 20 36 44 56 64 21 8 10 18 22 28 32 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 Knuckle
Manifold: Common SUP/Individual EXH Type Applicable solenoid valve series VZ3000 VK Common SUP/Individual EXH type VV5Z3-21-3 VZ VF Model no.
/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.
ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.0 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.0 0.6 0.4 0.5 mm 0.5 0.25 mm Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4
Polyester band Forklift insertion side Cardboard box 800 mm Less than 150 mm 300 mm or more or more Wooden skid Forklift insertion side Less than 150 mm
45, 60, 75, 100, 125, 150, 175, 200 Standard Non-lube Double acting Single rod 15, 30, 45, 60 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.
Overhang direction:L3[mm] 250 250 600mm stroke L3 m 200 200 500mm or less 150 150 600mm stroke or less 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 300 300 250 250 Overhang direction:L4[mm] L4 m Overhang direction:L4[mm] 600mm stroke 200 200 600mm stroke or less 500mm stroke or less 150 150 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 500 500
, 200, 250, 300, 350 400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact SMC if the maximum stroke will be exceeded.
Valve open (horizontal slit) Valve closed (vertical slit) 16-8-21
SOL. 2 () 2 ( ) 21 Compact Direct Operated Series VDW 2/3 Port Solenoid Valve for Fluid Control Specific Product Precautions 1 Be sure to read before handling. Refer to pages 18 through 21 for safety instructions and precautions for 2/3 port solenoid valve for fluid control.
, 200, 250, 300, 350 400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact P/A if the maximum stroke will be exceeded.
Panel mounting hole Push button (Extended) VFM350-02-32R/B/G/Y (Pilot exhaust port) JIS Symbol 0.5 MPa supply 4.8 mm P.T. 21 N F.O.F. (EXH port) 2-4.2 mounting hole (SUP CYL port) 1.7 mm O.T. 6.5 mm T.T. Panel mounting hole Push button (Flush) VFM350-02-33 (Pilot exhaust port) JIS Symbol 0.5 MPa supply 4.8 mm P.T. 21 N F.O.F.
entry) n: Stations L Stations Formula 20n + 21 20n + 30 2 61 70 3 81 90 4 101 110 5 121 130 6 141 150 7 161 170 8 181 190 9 201 210 10 221 230 11 241 250 12 261 270 13 281 290 14 301 310 15 321 330 L1 L2 3-7-33 34 Series VZS3000 Manifold Non plug-in type VV5ZS3-51Station 1Port size Grommet (G) 2-4.5 mounting hole 2n-Rc 1/8, 1/4 Manual override U side (n) (2) (1) Stations D side Courtesy
psig (1.0 MPa) 100 0.69 80 0.55 Delivery pressure (MPa) Delivery pressure (psig) 60 0.41 40 0.28 20 0.14 0 0.00 0 50 100 150 200 250 300 350 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International.
to 1000 150 to 700 150 to 700 10 8 8 8 26.5 22 20 20 12.5 11 10 10 24 22 22 18 46.5 37.5 33.5 22 17 17 13 21 19.5 19.5 15.5 55.5 49.5 45.5 40 7 6.8 6.8 6.8 30 28 28 25 227 199 186 186 55 40 40 40 75 55 55 55 51 42.5 34.5 14 12 10 M10 x 1.25 M14 x 1.5 7 56.2 Bore size Y X NN 264 232 219 215 P 181 159 146 146 S 10 8 8 8 Z ZZ Stroke range 1/8 1/8 1/8 1/4 23 20 20 20 27 25 25 21 40 32 25 20