Electric shock can result. 11 - Install the electric actuator and its peripheral devices on a fire-proof material. Direct installation on or near a flammable material may cause a fire. Do not install the product in a place subject to vibrations and impacts. It will cause failure or malfunction.
Implement measures to prevent any danger from occurring when operating the actuator. 11. Ventilation 2. Actuator drive When an actuator, such as a cylinder, is to be driven Provide ventilation when using a valve in a confined area, such as in a closed control panel.
Surge voltage intrusion It is possible to operate a valve in extreme temperatures, as low as 10C. Take appropriate measures to avoid the freezing of drainage, moisture, etc., in low temperatures.
Therefore, if the valve is to be energized for periods of longer than 30 minutes at a time or if during the hours of operation the energized period per day is longer than the de-energized period, we advise using a power-saving circuit valve. 11. Do not disassemble the product or make any modifications, including additional machining.
G G H H 3.1-11 Controller PSE100 Error Codes Precautions Error codes Be sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.3.0-7 to 3.0-9 for precautions on every series. Display Cause Solution Sensor is not connected. Connect sensor.
Rc 1/8 7 to 9 Rc 1/4 12 to 14 Rc 3/8 22 to 24 Rc 1/2 28 to 30 Rc 3/4 28 to 30 Rc 1 36 to 38 Rc 11/4 40 to 42 Rc 11/2 48 to 50 Rc 2 48 to 50 Reference How to tighten M5 threads on the fittings After tightening by hand, use a tightening tool to add about 1/6 turn more. But when using miniature fittings, after tightening by hand, use a tightening tool to add 1/4 turn more.
4.5 60 45 35 55 45 35 55 60 50 60 Rated value 10 104 VXF 2150 83 LVC DC 6 VXF 2160 AC 50 20 11 4.5 60 6 DC Rated value 10 105 LVA 85 VXF 2280 AC 50 40 18 7.5 60 8 DC Rated value 10 108 LVH 85 LVD LVQ LQ LVN TI/ TIL PA PAX PB 17-3-73 4 The VX series will be revised shortly.
(2 x 3 ) 2 x 2.8 2.2 2.6 2.2 (7.4) Normally closed 4.5 2 (OUT) 1 (IN) Universal 2 (OUT) 1(P) port 2(A) port 1 (IN) 3-port SX090/Universal Base hole dimension q 10 2 x M2 x 0.4 9.8 Thread depth: 6 or more Tightening torque: 0.1 to 0.14 Nm 3 4 4 1.7 1.7 11.6 0.8 2.45 1.5 2.3 (Lead wire AWG#26) 300 54 3.4 10 5 3 3 1.7 10 Base hole dimension w Mounting screw (Included) M2 x 11 2 x M2 x 0.4
Note 4) q Ambient temperature: 25C, w Circulating fluid temperature: 20C, e Rated circulating fluid flow rate, r Circulating fluid: Clear water, t Facility water temperature: 25C Note 5) Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temperature is 10C or less.
2 3.5 5 KRP-10 KRP-12 8 35 16 10 39 18.5 12 43 20 14 46 22 VMG 8 10 12 Applicable fitting Spatter Cover 1: KR (Applicable tube: FR soft nylon) Applicable fitting size Model Weight (g) D L KR-08C KR-06C 6 0.9 1.0 1.5 1.6 KR-10C KR-12C 15.5 9 17 9 20.8 10.5 22.8 10.5 8 10 12 When tube insert parts are in line as KQU Union Y, use KRC1.
Low temperature operation 1) The valve can be used in an ambient temperature of between 20 to 10C.
Furthermore, when using at low friction, it is also recommended to use clean air (atmospheric pressure dew point temperature of 10C) and install mist separator series AM (filtration degree 0.3 micron or less) or series AM + AMD (filtration degree 0.01 micron or less). 3. Install an after-cooler, air dryer or water separator, etc.
MHR MHQJ2-25S 14 25 49 643 Single acting MHQJ2-10C 4 MHK 10 7.8 90 6 MHQJ2-16C 16 26 181 Normally closed MHS 10 MHQJ2-20C 20 33 342 14 MHQJ2-25C 25 49 643 MHC Note 1) Values at the pressure of 0.5 MPa.
Refrigerant R134a (HFC) Standard Inlet Air Temperature IDFlE Series 1E, 2E, 3E, 4E, 6E, 8E, 11E, 15E1 (Inlet air temperature: 35C, Outlet air pressure dew point: 10C) How to Order IDF 8E 10 Nil A C G K L M R S T Size Symbol Air compressor size 1 1E 0.75 kW 2E 1.5 kW 3E 2.2 kW 4E 3.7 kW 6E 5.5 kW 8E 7.5 kW 11E 11 kW 15E1 15 kW 1 Note that the above values are for reference only.
Operation in low temperature conditions It is possible to operate a valve in extreme temperatures, as low as 10C. Take appropriate measures to avoid the freezing of drainage, moisture, etc., in low temperatures. use a suitable wrench to tighten the hexagonal portion of the body an additional two or three turns. For the tightening torque, refer to the table below. 5.
Ambient temperature Pressure dew point Working fluid Inlet air pressure Inlet air temperature Ambient temperature Power source Power consumption Circuit breaker Electrical specifications Operating conditions Rated conditions MPa C C V W A 160 285 Condenser Note 3) Refrigerant Air connection Drain connection Auto drain Weight Coating color Applicable compressor (screw type) Rc kg 35 27 kW 5.5 11
(Stacking base) Dimensions / Single unit (Base Mounted) 7 11 28 3 Specifications Poppet Valve construction Air, Inert gas Fluid Vacuum (1.33 x 102Pa) to max. operating press. (Refer to flow characteristics table below.)
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., "Cylinder, MXJ,
Specification: Standard Type (Not Clean Room), Bore Size: 4.5 mm, Symmetric Type: L (Symmetric), Stroke: 10mm, Adjuster: C (Metal Stopper Both Ends), Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Specification: Standard Type (Not Clean Room), Bore Size: 4.5 mm, Symmetric Type: L (Symmetric), Stroke: 10mm, Adjuster: C (Metal Stopper Both Ends), Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal