3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23 132.5 67.5 26 73 75, 100 85 7
Bottom mounting Bottom mounting Application Example Assembly lines, inspection lines etc. with turning operations Front mounting Side mounting Series Variations Bearing type Bore size (mm) Standard stroke (mm) Model Slide bearing MGTM 63 80 25, 50, 75, 100, 125, 150, 175, 200 Ball bushing bearing MGTL 100 8-24-2 3 Cylinder with Turntable Series MGT 63, 80 100 How to Order MX MTS M 63 50 11
Fig. 11 Removal of rod seal and cushion seal Squeeze the seal from the external circumference to lift one part of the seal, and remove it. Fig 12 How to remove piston seal 3) Tube gasket Take out with the precision screwdriver. 26 - 4-4-3. Grease C a u t i o n Use a specified grease.
As shown in Fig. 11, hold the piston seal with one hand and push it into the groove so that the piston seal can be lifted off and pulled out without using a precision screwdriver. The groove of the rod cover is deep, so if the rod seal is removed with a precision screwdriver, it might be damaged. Fig 10. Remove rod seal Pinch and pull out Fig 11.
MHCM2-7S D8.3 205.2 2-M2 x 0.4 thread (Mounting thread) 2-M2 x 0.4 depth 4 (Mounting thread) 2.5 2 1.5 When open 20 When closed 7 10 6 4.5 15 11 7.7 1.8 16.5 6 100.05 (23) M3 x 0.5 (Finger closing port) 2-M2 x 0.4 thread (Attachment mounting thread) 4 0 0.03 3 12-8-23
M5 x 0.8 (Finger opening port) D3 O 20S 13 3 23 7 M5 x 0.8 (Finger closing port) 4 2 MHY2-10D2 Opening/Closing direction through-hole type 4-3.4 (Hole for mounting attachment) 6 0.005 0.025 3 6 12 (Limted area for mounting attachment) Do not extend the attachment from limited area for mounting to avoid interference with the attachment or main body. 12-10-11 11 Series MHY2 Dimensions MHY2
MHCM2-7S D8.3 205.2 2-M2 x 0.4 thread (Mounting thread) 2-M2 x 0.4 depth 4 (Mounting thread) 2.5 2 1.5 When open 20 When closed 7 10 6 4.5 15 11 7.7 1.8 16.5 6 100.05 (23) M3 x 0.5 (Finger closing port) 2-M2 x 0.4 thread (Attachment mounting thread) 4 0 0.03 3 12-8-23
M5 x 0.8 (Finger opening port) D3 O 20S 13 3 23 7 M5 x 0.8 (Finger closing port) 4 2 MHY2-10D2 Opening/Closing direction through-hole type 4-3.4 (Hole for mounting attachment) 6 0.005 0.025 3 6 12 (Limted area for mounting attachment) Do not extend the attachment from limited area for mounting to avoid interference with the attachment or main body. 12-10-11 11 Series MHY2 Dimensions MHY2
Refer to front matters 42 and 43 for Safety Instructions and pages 3 to 11 for Actuator and Auto Switch Precautions. Operation Caution Selection 1. When cylinders are moved from the retraction end to the extension end or from the extension end to the retraction end, they must stop in an intermediate position, even for a moment, and then move to the stroke end.
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
Mass (g) Auto Switch Internal Circuit D-M9N D-M9P D-M9B Auto switch model 0.5 8 8 7 D-M9N 1 14 14 13 Lead wire length (m) DC (+) Brown 3 41 41 38 5 68 68 63 Main circuit of switch OUT Black Dimensions (mm) DC () Blue D-M9l M2.5 x 4 l Slotted set screw D-M9P DC (+) Brown Indicator light 2.6 Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC () Blue VNA D-M9B VNB 3.2 OUT
Tightening torque of the hexagon socket head set screw (M4 x 0.7) shall be 1 to 1.2Nm. 21 - < Applicable Auto switches > Solid state switch D-P3DWA How to mount and move the auto switch Fig. 11 Mount the auto switch mounting bracket 2 to the tie rod.
Gripping point . 11 3-5. Dimensions . 12 3-5-1. JMHZ2-16D-X7400B-DTP-(N/P) . 12 3-5-2. JMHZ2-16D-X7400B-HC10DT-(N/P) . 13 3-5-3. JMHZ2-16D-X7400B-HC10-(N/P) . 14 3-6. Connector and pin layout . 15 3-6-1. JMHZ2-16D-X7400B-DTP-(N/P) . 15 3-6-2. JMHZ2-16D-X7400B-(HC10DT/HC10)-(N/P) . 16 3-7. Center of gravity . 17 4Product Specifications . 18 4-1.
Air Cylinder Speed controller Solenoid valve Regulator Air source Air filter Fig. 11 Basic Circuit 28 6.
Order for tightening mounting screws 11 2-9-2. Auto switches When an auto switch is mounted or its set position is changed, refer to Fig. 4 to 11. C a u t i o n Use a specific mounting bracket (Page 19, Table 2) . Tighten mounting screws to the appropriate torque. The auto switch can only be used for cylinders with a built-in magnet for auto switch (e.g. CDA).
Lead wire length (m) Auto switch model MHC Electrical entry direction Load voltage Pre-wired connector Applicable load 5 (Z) Type Electrical entry Special function Indicator light Wiring (Output) 0.5 (Nil) 1 (M) 3 (L) DC AC Perpendicular In-line MHT M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire(NPN) IC circuit 5 V, 12 V 12 V 3-wire(PNP) Solid state auto switch MHY
Refer to front matters 42 and 43 for Safety Instructions and pages 3 to 11 for Actuator and Auto Switch Precautions. Selection Caution Mounting Caution Operate loads within the range of the operating limits. Select a model taking into consideration the allowable horizontal loads, rotational torque and eccentric loads that will apply.
(s P. 11 ) (2) The weight of a transferred object and transfer speed should be within the allowable range as shown in the graphs. (3) Overhang L3 should be 30 mm or less. V m L3 30 mm Caution (1) If a load is applied in the direction as shown on the right side, an eccentric load will be applied to the guide.