38(53) 50(63) 32(42) 5 3 1 23(30) 38(53) 32(42) 1 23(30) 2-3/8, 1/2, 3/4 30(42) 30(42) X(PE) port 1/8 2-3/8, 1/2, 3/4 3/8, 1/2, 3/4 R1, R2 port X(PE) port 1/8 30(42) 30(42) 3/8, 1/2, 3/4 R1, R2 port P port P port ( ): 3/4 Dimensions inside are for rubber seals. ( ): 3/4 3-10-25 Series VQ7-8 Construction DIN Terminal Type Metal seal Rubber seal type VQ7-8-FG-SVQ7-8-FG-S-R !
A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield (3) Cable color Terminal No.
Connection thread NPT H Effective area (mm) Weight g A L M Model (Width across flats) Applicable tubing AKH03-U10/32 AKH03-N01S AKH07-U10/32 AKH07-N01S AKH07-N02S AKH09-N01S AKH09-N02S AKH09-N03S AKH11-N02S AKH11-N03S AKH11-N04S AKH13-N03S AKH13-N04S 8 11.11 10-32 UNF 1/8 10-32 UNF 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 3/8 1/2 24.3 24.6 25.8 26.9 31 31.7 21.2 20.6 22.7 22.9 25 27.7 36 35.5 48.3
Metric size ZFC7 ZFC5 Symbol Applicable tubing O.D. 4 6 8 10 12 3 4 5 6 7 Option Nil B None With bracket Inch size B D E F 5/32" 1/4" 5/16" 3/8" Max.
(Example) CDLSL140-100 3 wire (NPN equiv.)
Combinations Converter nominal size Control valve Valve unit size Combined valve 2 0, 1, 2, 3 0, 1, 2, 3 0, 1, 2, 3 2 0, 1, 2, 3 0, 1, 2, 3 0, 1, 2, 3 2 0, 1, 2, 3 0, 1, 2, 3 2 0, 1, 2, 3 0, 1, 2, 3 0 1 2 3 0 1 2 3 0 1 2 0 1 2 S 63 Speed controller Combined valve (Stop valve, Skip valve) The stop valve for intermediate stopping and the skip valve for last-forwarding are compound integrated
33 33 34 36 54 55 57 54 55 57 94 96 14.5 5 32" 1 8 14.2 36.1 31.1 30.5 25.5 14.3 3 16" 16.5 17 18.5 14.5 16.5 17 18.5 21 17 18.5 21 17 18.5 21 21 22 12 1 4" 5 16" 5 32" 3 16" 17.2 17 1 4 1 4" 18.5 39.4 34.4 32.0 26.6 5 16" 3 8" 19 1 4" 1 4 45.9 40.9 38.1 33.1 23.0 19 20.3 5 16" 3 8" 1 4" 5 16" 19.4 45.0 40.0 37.6 32.6 19 3 8 23.0 3 8" 3 8" 1 2 18.6 24 22.4 54.6 47.1 44.5 37.0 1 2" Note 1
Rc G Note) Station 8 only 8 (Ordering example) If installed on station 1 and station 3: ZZX106-R 1 pc. ZX1101-K15LZ-EL(-Q) 6 pcs. ZX1-R1-1 ZX1-R1-3 ZX1-R16 (Dummy spacer) 4 pcs. NPTF When spacers are mounted alternately, specify them together. When retrofitting, 3 pcs. of M2.5 x 32 (for ZX) are necessary.
8 43 116 11 19 15 63 55 80 R0.5 M10 x 1.5 28 8 80 60 22.4 30 17 17 22 10 25 M18 x 1.5 30 3/8 47 120 11 21 15 80 65 90 R2.5 M12 x 1.75 32 8 100 75 28 32 22 20 26 13 29 M22 x 1.5 35 1/2 57 132 11 26 25 100 80 100 R2.5 M12 x 1.75 38 6.5 118 90 35.5 35 27 19 27 13 34 M27 x 2 35 1/2 66 140 12 34 32 125 80 100 R2.5 M14 x 2 38 6.5 140 112 35.5 35 27 19 27 15 34 M27 x 2 35 1/2 77 140 12 34 32 160
wire (NPN) 3 wire (PNP) IC circuit A96 A96V 5V F9N F9NV F9P F9PV 2 wire F9B F9BV Relay, PLC Grommet Yes 12V 24V 3 wire (NPN) 3 wire (PNP) F9NW F9NWV Diagnostic indication F9PW F9PWV 2 color indicator 2 wire F9BW F9BWV Lead wire length symbols: 0.5m Nil (Example) F9NW 3m...
Non-rotating Rod Accuracy (No load/At retraction of the rod at the locking plateside) Bore size (mm) 10 0.8 16 20 25 0.5 32 Non-rotating rod accuracy Allowable Rotational Torque Bore size (mm) 10 16 20 25 32 0.20 Allowable rotational torque (Nm) Minimum Operating Pressure 0.02 0.04 0.10 0.15 (MPa) Bore size (mm) 10 16 20 25 32 3.
center 3 position exhaust center 3 position closed center 3 position pressure center (1) 3 position exhaust center 3 position closed center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) Note 1) Except VQZ1000 and metal seal.
Please refer to the electric wave data below. 3 5 7 (In the case of SY **0T, the electric wave form of energy saving type) SY3000*-OMJ0003-A -9- Specific Product Precautions 3 Be sure to read before handing.
Inch size 1/8" 5/32" 1/4" 5/32" 1/4" 1/4" 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Flow Direction Symbol on Body Free flow 0.3 0.4 0.6 0.4 0.6 1.0 1.2 1.1 1.6 2.2 2.6 2.4 3.5 Controlled flow 0.3 0.4 0.6 1.0 1.2 1.3 1.9 2.7 3.3 2.8 4.1 C values: Sonic conductance dm3/(sbar) Symbol b values: Critical pressure ratio Free flow 0.3 0.2 0.3 0.1 0.2 0.2 0.3 0.2 Controlled flow 0.2 0.3 0.4 0.2 0.2 0.3 0.1
A B C D E F 8 6 4 2 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 Input/output connector (CS0) 3 7 5 1 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 Power supply terminal block 20 18 16 14 12 10 8 6 4 2 Input/output connector (CS1) 19 17 15 13 11 9 7 5 3 1 Green Red F E D C B A 9 8 7 6 5 4 3 2 1 0 4 3 2 1 CN1 4 3 2 1 CN2 4 3 2 1 CN3 4 3 2 1 CN4 4 3 2 1 CN5 4 3 2 1 CN6 4 3 2 1 CN7 4 3 2
ZFC1 ZFC3 ZFC5 ZFC7 1 2 V 2 3.2 V V 3 4 V V 4 6 V V 5 8 V 6 10 V 7 12 V Option Nil None B With bracket Inch size A 1/8" V V B 5/32" V V D 1/4" V V E 5/16" V F 3/8" V Max. Operating Pressure and Operating Temperature Specifications Model ZFC1l ZFC3l ZFC5l ZFC7l Max. operating pressure [MPa] 1.0 Port size (Applicable tubing O.D.)
ZPG25B-7A-X2 25 27 16 28 29.5 34 ZPG32B-7A-X2 32 34 18.9 37 34.5 39 14 -12No.
Stroke can be selected to suit the workpiece. 8 12 16 20 8 12 16 20 Short mm mm mm mm Medium 16 24 32 40 mm mm mm mm Long 32 48 64 80 mm mm mm mm 12-3-2 3 Improved mounting repeatability With positioning pin holes Auto switches can be mounted on both sides.
Stroke can be selected to suit the workpiece. 8 12 16 20 8 12 16 20 Short mm mm mm mm Medium 16 24 32 40 mm mm mm mm Long 32 48 64 80 mm mm mm mm 12-3-2 3 Improved mounting repeatability With positioning pin holes Auto switches can be mounted on both sides.
8 1/2 3/4 1 1 1/4 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 5 213 57 275 156 80 50 1.8 96 105 2 x M8 x 1.25 19 0 236 61 340 175 60 65 2.5 120 136 2 x M10 x 1.5 15 0 1 0 1 32 (1 1/4B) 32 36 46 16 20 25 32 36 46 60 70 16 20 25 32 36 46 16 20 25 32 36 46 17 20 20 12 12 17 17 20 20 27 27 12 12 17 17 20 20 22 22 22 22 30 30 56 65 73 36 40 48 56