SMC Corporation of America
Elite Part Number Search
Search Results "CXSL20-70-Y59BSAPC"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, H/PRECISION, ACTUATOR, MYH GUIDED CYLINDER, IE, 25MM MYH DBL-ACT AUTO-SW, 8.01012 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, H/PRECISION, ACTUATOR, MYH GUIDED CYLINDER, IE, 25MM MYH DBL-ACT AUTO-SW, 9.54125 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, MECH JOINT, ACTUATOR, MY1B GUIDED CYLINDER, LE, 32MM MY1B DBL-ACT AUTO-SW, 15.36621 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, SLIDE BEARING, ACTUATOR, MGQ GUIDED CYLINDER, MM, 40MM MGQ SLIDE BEARING, 4.73993 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520040MGQM40??1.65??2.242.462.873.283.694.104.51

The MHS is the latest in the family of rotary operated parallel style grippers. This compact gripper is available in 10 different bore sizes with choices of 2, 3 and 4 fingers which generate gripping forces up to 1270 N. Pinholes are incorporated as standard, facilitating accurate mounting which is achieved through either body tapped or through-hole mounting. By using a wedge cam construction

These grippers utilize a wedge cam design to minimize their size yet retains a high holding force. The small size of the units makes them well suited for end-of-arm or space constrained pick-and-place applications. The three-finger design of the MHS3 makes it ideal for gripping round objects and loading or unloading items from the chuck of a machine tool. 3 finger parallel style air gripper

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, DUAL ROD, ACTUATOR, CXS GUIDED CYLINDER, GB, 15MM CXS BALL BEARING, 1.32277 lb

Series MHL air grippers are designed for applications that require a wide travel range of gripper fingers. The MHL is ideal for gripping many different sized parts. Finger motion is synchronized by a rack-and-pinion mechanism. The double piston construction creates a compact gripper with large holding force. Available in bore sizes 10, 16, 20, 25, 32 and 40. Axial mounting * or lateral mounting

M12 (4 ) 1 24 V 2 A/D DC24 V 3 0 V 4 5 FE FE 100 k 50 IP67 -16No.EX-OMN0037CN-A 0V 2 EX600 4 (-)2 (+) 4 3 4 -17No.EX-OMN0037CN-A LED LED OFF 0 1 () (SI ) -18No.EX-OMN0037CN-A EX600-AXA M12 (5 ) 1 2 (1 /) () DC24 V Class22 A 0.5 A/ 12 bit 010 V15 V05 V 020 mA420 mA 16 bit -1010 V-55 V -2020 mA 15 V 40 mA 100 k 50 (25 ) 0.05F.S. (25 ) 0.15F.S. (25 ) 0.5F.S. 0.6F.S. 70

Forgotten the security code 70 Troubleshooting 71 Specifications 78 Dimensions 80 -1No.PS-OMW0014-B Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Refer to the straight inlet piping length and accuracy graph (page 70). Avoid sudden changes in the piping size on the IN side of the product. Do not release the OUT side piping port of the product directly to the atmosphere without the piping connected. If the product is used with the piping port released to atmosphere, the accuracy may vary.

mincfm 10 3 Lft -25525 L/min -501050 L/min -1002100 L/min (-44 [ 0]) (-99 [ 0]) (-1919 [ 0]) 0999,999,990 L 1 L/min 10 L LCD 4 7 ON (OUT1/OUT2 IP40 AC1000 V 1 50M (DC500 V ) 050 -1060 () 3585RH() CERoHS Rc1/2NPT1/2G1/2 Rc3/4NPT3/4G3/4 ADCPPSSUS304HNBR 100 g 155 g +35 g +25 g +30 g -63No.PF-OMP0001CN-F 1 () 2()10024 551005009.5 221002003.8 3OUT 40()90% ON(OFF) 5 6 70

IN(70) IN OUT IN OUT 8cm M8 Rc1/2NPT1/2Rc3/4NPT3/4 2830 Nm 1/2 30 mm 3/4 35 mm 9mm 2F.S. -17No.PF-OMS0001CN-A FG 1 DC(+) 2 OUT2// 3 DC(-) 4 OUT1 -18No.PF-OMS0001CN-A NPN(2 ) PFMC7--ADC(+) OUT1 OUT2 DC(-) 28V 80 mA 1 V NPN(1 )(15 V) PFMC7--CNPN(1 )(420 mA) PFMC7--DDC(+) OUT1 DC(-) 28V 80 mA 1 V C15 V 1 k D420 mA 600 50 NPN(1 ) PFMC7--GDC(+) OUT1 DC(-) 28V 80 mA 1 V 0.4V ()30msec

. (-70 to 0 kPa) Rated pressure range -70 kPa to 300 kPa Operating pressure range -100 kPa to 400 kPa Proof pressure 500 kPa (Non-linear output) 5 Output voltage 1 to 5 V Analogue output Response time 5 ms or less Output impedance Approx. 1 k Supply voltage 12 to 24 VDC10%, ripple(p-p) 10% or less (with polarity protection) Power consumption 16 mA or less Enclosure IP40 Operating fluid temperature

(Displays 0 when the value is (Displays 0 when the value is below 60 L/min) below 120 L/min) 70 to 1050 L/min 140 to 2100 L/min 7.0 0 to 7%F.S. (Displays 0 when the value is (Displays 0 when the value is below 70 L/min) below 140 L/min) 80 to 1050 L/min 160 to 2100 L/min 8.0 0 to 8%F.S.

No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.

Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g -13No.LFE*-OMZ0011 Summary of Product Parts Body Lead wire and M12 connector (4 pins) Display (Option) Connector Piping port Piping port Bracket (Option) Description Function Connector The part to which Lead wire and M12 connector are connected.

Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g -12No.LFE*-OMZ0012 Summary of Product Parts Body Lead wire and M12 connector (4 pins) (Option) Connector Piping port Piping port Bracket (Option) Description Function Connector The part to which Lead wire and M12 connector are connected.

Ratio of discharge amount to fresh water () 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPas) mPas Recommended typical condition B: Calculate discharge amount of fluid with viscosity 100mPas in case of discharge rate 4.5L/min and discharge pressure 0.1MPa. 1. Find ratio of discharge rate to fresh water for the fluid with viscosity 100mPas from the graph.

Ratio of discharge amount to fresh water () 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPas) mPas Recommended typical condition B: Calculate discharge amount of fluid with viscosity 100mPas in case of discharge rate 4.5L/min and discharge pressure 0.1MPa. 1. Find ratio of discharge rate to fresh water for the fluid with viscosity 100mPas from the graph.