Model of Switch spacer BMY3-016 33 - Auto switch operation principle Fig. (14) Auto switch operation principle In the diagram above, auto switch B is ON. When pressure is applied from A, the piston moves to B, causing the shaft to rotate clockwise. At this time, magnet B goes out of the movement range of auto switch B, causing auto switch B to turn OFF.

PF3W511/521 (Vinyl chloride piping) -38No.PF-OMN0010-J Flow characteristics of the flow rate adjustment valve PF3W504S PF3W520S PF3W540S -39No.PF-OMN0010-J Analogue output Analogue output (Flow) (PF3W504/520/540) A B C Voltage output 1 V 1.5 V 5 V Current output 4 mA 6 mA 20 mA (PF3W511) A B C Voltage output 1 V 1.4 V 5 V Current output 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C Voltage output

Dimensions H Bracket K L N M D Auto drain (MAX1.6MPa) C I Bracket (accessory) () P E A F J B 1/4 1/4 female Maintenance G OUT IN Drain space Drain guide A A 3/8 female 3/8 G Maintenance Drain space Thread type Rc, G: 10 NPT: 3/8 Rc,G10 NPT3/8" Maintenance space Drain G Auto drain (MAX1.0MPa) Auto drain (MAX1.6MPa) Drain guide B C D E F G Model Port size A AFF,AM,AMD 70D 11 1/2

B 20 14 12 P = 43 A P = 43 PA 23 A A B B 14 12 A PA PA L1 L2 L2 L1 B B B 14 12 A A A A B 14 A A PA B B (2n 1/8) 4n-1/4, 3/8 2, 4 port PA L-side R-side L-side R-side D-side D-side 89 3 89 16 141 (Single) 141 (Single) 55 44 186 (Double) 186 (Double) 196 (3 position) 196 (3 position) 77.5 Bottom ported M12 connector L: Dimensions n: Stations 141.5 L n 1 Formula 2 3 4 5 6 7 8 9 10 121 5 1 12

Fix the end plate at the valve side while referring to the operation manual of the corresponding valve manifold. n (Number of connected units)10 -15No.EX-OMN0028-B DIN rail mounting (Available for series other than SY series.

0.5MPa 1000 800 600 0.3MPa 400 200 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 Shim thickness (mm) 0.3MPa Recommended shim thickness 0.5MPa 0.7MPa 10 - Clamp arm 4 n Relation between arm length and clamping force CKZ3N-X2742A type CKZ3T-X2734 type n Allowable arm length CKZ3N-X2742A type CKZ3T-X2734 type 11 - n Allowable load mass CKZ3N-X2742A type CKZ3T-X2734 type 12 - n Mounting of the

VH Push button (Extended) VZM550-01-32R/B/G/Y Panel mounting hole VHS JIS symbol (Pilot exhaust port) 0.5 MPa supply 4.8 mm P.T. 21 N F.O.F. 2-3.2 mounting hole 1.7 mm O.T. 6.5 mm T.T.

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety, etc. *2) Labor Safety and Sanitation Law, etc.

a Mounting B B B B With bracket H H H H With hexagon panel nut (for panel mount) + Pressure gauge Nil Nil Nil Nil Without pressure gauge Option Note1) Semi-standard G G G G Round type pressure gauge 5 EA EA EA EA NPN open collector 1 output b With digital pressure switch PNP open collector 1 output EB EB EB EB EC EC EC EC NPN open collector 1 output + Analog voltage output NPN open collector

a Mounting B B B B With bracket H H H H With hexagon panel nut (for panel mount) + Pressure gauge Nil Nil Nil Nil Without pressure gauge Option Note1) Semi-standard G G G G Round type pressure gauge 5 EA EA EA EA NPN open collector 1 output b With digital pressure switch PNP open collector 1 output EB EB EB EB NPN open collector 1 output + Analog voltage output EC EC EC EC NPN open collector

n: Station Formula L1 = 87 x n + 83 L2 307 394 481 568 655 742 829 916 1003 L2 = 87 x n + 133 Model 2 257 3 344 4 431 5 518 6 605 7 692 8 779 9 866 10 953 L L1 VVPA450 L3 L4 356 464 572 680 788 896 1004 L4 = 108 x n + 140 L3 = 108 x n + 90 306 414 522 630 738 846 954 VVPA460 ( ) for VVPA460 5-3-30

Accessory/ Option Specifications Combinations : Combination available : Combination not available : Varies depending on the model : Available only with NPT thread Combination Accessory Option specifications Applicable regulators Symbol Accessory/ Option specifications B E G P 1 N R Z AR30 to 60 With bracket (with set nut) B Option specifications Accessory Square embedded type pressure gauge

03 03 03 03 3/8 04 04 04 04 1/2 4 + Nil Nil Nil Nil Without mounting option a Mounting B B B B With bracket H H H H With hexagon panel nut (for panel mount) + Pressure gauge Nil Nil Nil Nil Without pressure gauge Option Note1) G G G G Round type pressure gauge 5 EA EA EA EA NPN open collector 1 output b With digital pressure switch EB EB EB EB PNP open collector 1 output EC EC EC EC NPN

Gripping force N = 38 N A gripping force of 38 N satisfies the required gripping force of 29.4 N. Therefore, the selection of MHF2-12D is appropriate.

Dimensions EX600-DY B EX600-DY E -44No.EX-OMN0036-B EX600-DY F -45No.EX-OMN0036-B Digital I/O unit Model Indication and How to Order EX600-DM Digital I/O Connector and number of I/O Symbol Connector Number of inputs Number of outputs Input and Output type E D-sub connector (25 pin) 8 inputs 8 outputs Symbol Content F Spring type terminals (32 pin) 8 inputs 8 outputs P PNP N NPN Names and

B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when workpiece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when workpiece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the workpiece for a few times. The optimum values will be set automatically.

Matsushita Electric Industrial Co., LTD For side mount type, motor specifications L, M, N, and P are used.

flats 17 Clearance for maintenance G 1/4 Drain A Metal bowl 10-/21-AF20-A 10-/21-AF30-A to 60-A With bowl guard Metal bowl with level gauge Metal bowl Applicable model Semi-standard specifications Dimensions B B B B Metal bowl with level gauge Bracket mounting size Semi-standard specifications Standard specifications Model B Metal bowl With bowl guard B B V U T R Q N M J G D E C B A P S

Hysteresis mode GPM gal (US) OFF n-1 n-2 GPM = gal (US)/min High flow rate Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min or l).] "n" H (fixed hysteresis) = 3 digits H H ON Window comparator mode NO OFF n-1 n-2 High flow rate 5 Series PFA Flow Rate Setting Flow rate setting mode (manual) 1.